Honeywell Safety Manager Missing Authentication For Critical Function (CVE-2022-30313, CVE-2022-30314, CVE-2022-30315, CVE-2022-30316, CVE-2022-30317)

2022-06-2200:00:00
This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
39
honeywell safety manager
missing authentication
critical function
cve-2022-30313
cve-2022-30314
cve-2022-30315
cve-2022-30316
cve-2022-30317
ot:icefall
vulnerabilities
insecure-by-design
ot devices
remediation
nessus
inventory
environments
monitoring
tenable.ot
manual verification
vendor advisory
scanner

CVSS3

9.8

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

AI Score

6.7

Confidence

Low

EPSS

0.007

Percentile

80.1%

The device may be vulnerable to flaws related to OT:ICEFALL. These vulnerabilities identify the insecure-by-design nature of OT devices and may not have a clear remediation path. As such, Nessus is unable to test specifically for these vulnerabilities but has identified the device to be one that was listed in the OT:ICEFALL report. Ensure your OT deployments follow best practices including accurate inventory, separation of environments, and monitoring. This plugin will trigger on any device seen by Tenable.OT that matches a family or model listed in the OT:ICEFALL report.

Note: All findings need to be manually verified based on the advisory from the vendor, once released.

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(500656);
  script_version("1.7");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/03/04");

  script_cve_id(
    "CVE-2022-30313",
    "CVE-2022-30314",
    "CVE-2022-30315",
    "CVE-2022-30316",
    "CVE-2022-30317"
  );

  script_name(english:"Honeywell Safety Manager Missing Authentication For Critical Function (CVE-2022-30313, CVE-2022-30314, CVE-2022-30315, CVE-2022-30316, CVE-2022-30317)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset may be affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"The device may be vulnerable to flaws related to OT:ICEFALL. These vulnerabilities
identify the insecure-by-design nature of OT devices and may not have a clear
remediation path. As such, Nessus is unable to test specifically for these
vulnerabilities but has identified the device to be one that was listed in the
OT:ICEFALL report. Ensure your OT deployments follow best practices including
accurate inventory, separation of environments, and monitoring. This plugin will
trigger on any device seen by Tenable.OT that matches a family or model listed
in the OT:ICEFALL report.

Note: All findings need to be manually verified based on the advisory from the vendor, once released.

This plugin only works with Tenable.ot. Please visit
https://www.tenable.com/products/tenable-ot for more information.");
  # https://www.cisa.gov/uscert/ncas/current-activity/2022/06/22/cisa-releases-security-advisories-related-oticefall-insecure
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?4901fbd6");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-207-02");
  script_set_attribute(attribute:"see_also", value:"https://www.forescout.com/research-labs/ot-icefall/");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Honeywell recommends the following:

- For CVE-2022-30315 and CVE2022-30313: 
    - Safety Manager and FSC use a key switch control to prevent users from downloading unauthorized safety logic. When
the key switch is in the locked state, users cannot download any logic whatsoever.
    - Safety builder should reside on a station with restrictive access controls. Network controls should be in place to
limit the nodes permitted to communicate the builder protocol to the safety manager.
    - Users are advised to follow the Safety Manager release documentation.
- For CVE-2022-30314: 
    - Safety Manager R160.1 and later releases include a remediation for this item. R160.1 was introduced in October
2014. Users are advised to operate on the latest release and point release.
    - Customers should isolate process control networks following our security best practices.
    - Users are advised to follow the Safety Manager Release documentation; see the section “Security Recommendations
and Best Practices”.
- For CVE-2022-30316: 
    - The Safety Manager key switch prevents unauthorized firmware from being installed. Users are advised to monitor
the key switch position.
    - Users are advised to follow the Safety Manager Release documentation; see the section “Security Recommendations
and Best Practices”.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-30315");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/06/22");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/06/22");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/h:honeywell:experion");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Honeywell");

  exit(0);
}

include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Honeywell');

var asset = tenable_ot::assets::get(vendor:'Honeywell');

var vuln_cpes = {
    "cpe:/h:honeywell:experion" : {},
    "cpe:/h:honeywellprocess:experion" : {}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
honeywellexperioncpe:/h:honeywell:experion

CVSS3

9.8

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

AI Score

6.7

Confidence

Low

EPSS

0.007

Percentile

80.1%