Lucene search
K

13311 matches found

Cvelist
Cvelist
added 2024/05/07 10:55 p.m.29 views

CVE-2023-35748 D-Link DAP-2622 DDP Firmware Upgrade Server IPv6 Address Stack-based Buffer Overflow Remote Code Execution Vulnerability

D-Link DAP-2622 DDP Firmware Upgrade Server IPv6 Address Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DAP-2622 routers. Authentication is not required to exploit...

8.8CVSS9.2AI score0.00593EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 2024/05/07 10:54 p.m.24 views

CVE-2021-34982 NETGEAR Multiple Routers httpd Stack-based Buffer Overflow Remote Code Execution Vulnerability

NETGEAR Multiple Routers httpd Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of multiple NETGEAR routers. Authentication is not required to exploit this vulnerability. The...

8.8CVSS7.9AI score0.00576EPSS
Exploits0References2
CVE
CVE
added 2024/05/07 10:54 p.m.81 views

CVE-2021-34982

The CVE-2021-34982 entry describes a pre-auth, remote code execution vulnerability in the httpd service of NETGEAR routers. The flaw is a stack-based buffer overflow caused by unchecked length of user-supplied data in the strings file, leading to code execution with root privileges when a network...

8.8CVSS9.1AI score0.00576EPSS
Exploits0References2Affected Software1
NVD
NVD
added 2024/05/06 8:15 p.m.30 views

CVE-2024-33599

nscd: Stack-based buffer overflow in netgroup cache If the Name Service Cache Daemon's nscd fixed size cache is exhausted by client requests then a subsequent client request for netgroup data may result in a stack-based buffer overflow. This flaw was introduced in glibc 2.15 when the cache was...

8.1CVSS4.8AI score0.0131EPSS
Exploits0References5
CVE
CVE
added 2024/05/06 7:21 p.m.6571 views

CVE-2024-33599

CVE-2024-33599 affects the GNU C Library (glibc) with a stack-based overflow in the netgroup cache used by nscd when the fixed-size cache is overwhelmed by client requests. The flaw was introduced in glibc 2.15 and is present only in the nscd binary; exploitation can impact confidentiality, integ...

8.1CVSS8.4AI score0.0131EPSS
Exploits0References5Affected Software1
Cvelist
Cvelist
added 2024/05/06 2:32 p.m.22 views

CVE-2024-21474 Stack-based Buffer Overflow in PMIC

Memory corruption when size of buffer from previous call is used without validation or re-initialization...

8.4CVSS8.9AI score0.00111EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2024/05/06 2:32 p.m.22 views

CVE-2024-21474 Stack-based Buffer Overflow in PMIC

Memory corruption when size of buffer from previous call is used without validation or re-initialization...

8.4CVSS7.4AI score0.00111EPSS
Exploits0References1
Tenable Nessus
Tenable Nessus
added 2024/05/06 12:0 a.m.46 views

Oracle Linux 9 : gstreamer1-plugins-bad-free (ELSA-2024-2287)

The remote Oracle Linux 9 host has packages installed that are affected by multiple vulnerabilities as referenced in the ELSA-2024-2287 advisory. - CVE-2023-40474: Integer overflow leading to heap overwrite in MXF - CVE-2023-40475: Integer overflow leading to heap overwrite in MXF - CVE-2023-4047...

8.8CVSS7AI score0.02009EPSS
Exploits0References5
Cvelist
Cvelist
added 2024/05/05 6:31 a.m.25 views

CVE-2024-4497 Tenda i21 formexeCommand stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.144656. It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to th...

9CVSS8.9AI score0.01453EPSS
Exploits0References4
Vulnrichment
Vulnrichment
added 2024/05/05 6:31 a.m.16 views

CVE-2024-4497 Tenda i21 formexeCommand stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.144656. It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to th...

9CVSS6.9AI score0.01453EPSS
Exploits0References4
NVD
NVD
added 2024/05/05 6:15 a.m.16 views

CVE-2024-4496

A vulnerability was found in Tenda i21 1.0.0.144656. It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed ...

9CVSS8.9AI score0.01453EPSS
Exploits0References4
NVD
NVD
added 2024/05/05 6:15 a.m.11 views

CVE-2024-4495

A vulnerability was found in Tenda i21 1.0.0.144656 and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the publ...

9CVSS8.8AI score0.01453EPSS
Exploits0References4
Cvelist
Cvelist
added 2024/05/05 6:0 a.m.24 views

CVE-2024-4496 Tenda i21 formWifiMacFilterSet stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.144656. It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed ...

9CVSS9AI score0.01453EPSS
Exploits0References4
Vulnrichment
Vulnrichment
added 2024/05/05 6:0 a.m.11 views

CVE-2024-4496 Tenda i21 formWifiMacFilterSet stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.144656. It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed ...

9CVSS7AI score0.01453EPSS
Exploits0References4
CVE
CVE
added 2024/05/05 6:0 a.m.60 views

CVE-2024-4496

CVE-2024-4496 : A stack-based buffer overflow exists in the Tenda i21 firmware (version 1.0.0.14(4656)) originating from the parameter ssidIndex in the function formWifiMacFilterSet . The vulnerability allows remote attackers to trigger overflow, potentially leading to arbitrary code execution or...

9CVSS6.9AI score0.01453EPSS
Exploits0References4Affected Software1
Cvelist
Cvelist
added 2024/05/05 5:31 a.m.12 views

CVE-2024-4495 Tenda i21 formWifiMacFilterGet stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.144656 and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the publ...

9CVSS8.9AI score0.01453EPSS
Exploits0References4
Vulnrichment
Vulnrichment
added 2024/05/05 5:31 a.m.15 views

CVE-2024-4495 Tenda i21 formWifiMacFilterGet stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.144656 and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the publ...

9CVSS6.9AI score0.01453EPSS
Exploits0References4
CVE
CVE
added 2024/05/05 5:31 a.m.56 views

CVE-2024-4495

CVE-2024-4495 affects Tenda i21 (firmware 1.0.0.14(4656)). The issue is in the function formWifiMacFilterGet where the index argument can be mishandled, causing a stack-based buffer overflow. Several connected sources confirm a remote-exploit capable scenario with this vulnerability, rated high/s...

9CVSS6.8AI score0.01453EPSS
Exploits0References4Affected Software1
NVD
NVD
added 2024/05/05 5:15 a.m.7 views

CVE-2024-4494

A vulnerability has been found in Tenda i21 1.0.0.144656 and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched...

9CVSS8.9AI score0.01453EPSS
Exploits0References4
Vulnrichment
Vulnrichment
added 2024/05/05 5:0 a.m.10 views

CVE-2024-4494 Tenda i21 setUplinkInfo formSetUplinkInfo stack-based overflow

A vulnerability has been found in Tenda i21 1.0.0.144656 and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched...

9CVSS7AI score0.01453EPSS
Exploits0References4
Rows per page
Query Builder