Lucene search
+L

4843 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/07/31 12:00 a.m.•6 views

CVE-2013-4912: Improper Input Validation

Open redirect vulnerability in Siemens WinCC TIA Portal 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product...

5.8CVSS6AI score0.02067EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/07/31 12:00 a.m.•5 views

CVE-2013-4911: Cross-Site Request Forgery (CSRF)

Cross-site request forgery CSRF vulnerability in Siemens WinCC TIA Portal 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product...

6.8CVSS6AI score0.0108EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2013/07/31 12:00 a.m.•5 views

PT-2013-5267

Name of the Vulnerable Software and Affected Versions Siemens WinCC TIA Portal versions 11 and 12 before 12 SP1 Description The issue allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels. This is d...

5.8CVSS0.02067EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
•added 2013/07/31 12:00 a.m.•4 views

PT-2013-5266

Name of the Vulnerable Software and Affected Versions Siemens WinCC TIA Portal versions 11 through 12 before 12 SP1 Description A cross-site request forgery CSRF issue exists due to improper configuration of SIMATIC HMI panels by the WinCC product, allowing remote attackers to hijack the...

6.8CVSS0.0108EPSS
SaveExploits0References8
Check Point Advisories
Check Point Advisories
•added 2013/06/30 12:00 a.m.•41 views

Siemens SIMATIC WinCC RegReader ActiveX Control Buffer Overflow (CVE-2013-0674)

A stack-based buffer overflow vulnerability has been reported in Siemens SIMATIC WinCC...

6.9AI score0.03361EPSS
SaveExploits0
NVD
NVD
•added 2013/06/14 7:55 p.m.•39 views

CVE-2013-3958

The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request...

7.5CVSS6.6AI score0.01934EPSS
SaveExploits0References1
Prion
Prion
•added 2013/06/14 7:55 p.m.•38 views

Code injection

The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted U...

4CVSS6.6AI score0.01332EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
•added 2013/06/14 7:00 p.m.•56 views

CVE-2013-3957

SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors...

8.2AI score0.01784EPSS
SaveExploits0References1
CVE
CVE
•added 2013/06/14 7:00 p.m.•90 views

CVE-2013-3957

CVE-2013-3957 describes an SQL injection vulnerability in the Web Navigator login screen of Siemens WinCC prior to version 7.2 Update 1 (used in SIMATIC PCS7 8.0 SP1 and earlier). The issue arises from input handling in the login/UI that can be manipulated to inject SQL statements through unspeci...

7.5CVSS8.5AI score0.01784EPSS
SaveExploits0References1Affected Software2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/06/14 12:00 a.m.•6 views

CVE-2013-3958: Undefined Security Weakness

The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request...

7.5CVSS5.8AI score0.01934EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/06/14 12:00 a.m.•7 views

CVE-2013-3957: Improper Neutralization of Special Elements used in an SQL Command

SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors...

7.5CVSS6.4AI score0.01784EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/06/14 12:00 a.m.•7 views

CVE-2013-3959: Exposure of Sensitive Information to an Unauthorized Actor

The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted U...

4CVSS5.9AI score0.01332EPSS
SaveExploits0References2
OpenVAS
OpenVAS
•added 2013/04/25 12:00 a.m.•47 views

Siemens SIMATIC S7-1200 Multiple DoS Vulnerabilities (SSA-724606)

Siemens SIMATIC S7-1200 devices are prone to multiple denial of service DoS vulnerabilities. SPDX-FileCopyrightText: 2013 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only CP...

7.8CVSS7.2AI score0.02392EPSS
SaveExploits1References3
CVE
CVE
•added 2013/04/22 1:00 a.m.•82 views

CVE-2013-0700

Siemens SIMATIC S7-1200 PLC family (2.x/3.x) is affected by CVE-2013-0700, a denial-of-service vulnerability triggered by specially crafted packets to TCP port 102 (ISO-TSAP). The issue is a remote DoS that can force defect-mode transitions and control outages. Affected software components are th...

7.8CVSS6.7AI score0.02392EPSS
SaveExploits1References2Affected Software1
CVE
CVE
•added 2013/04/22 1:00 a.m.•82 views

CVE-2013-2780

CVE-2013-2780 affects Siemens SIMATIC S7-1200 PLCs (2.x and 3.x). The vulnerability permits remote DoS by sending specially crafted packets to UDP port 161 (SNMP), causing a defect-mode transition and control outage. The NVD entry assigns CVSS v2 base score 7.8 (AV:N/AC:L/Au:N/C:N/I:N/A:C). Explo...

7.8CVSS5.9AI score0.02392EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/04/22 12:00 a.m.•4 views

CVE-2013-0700: Undefined Security Weakness

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service defect-mode transition and control outage via crafted packets to TCP port 102 aka the ISO-TSAP port...

7.8CVSS7.3AI score0.02392EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/04/22 12:00 a.m.•5 views

CVE-2013-2780: Undefined Security Weakness

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service defect-mode transition and control outage via crafted packets to UDP port 161 aka the SNMP port...

7.8CVSS5.9AI score0.02392EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2013/04/16 12:00 a.m.•2 views

PT-2013-1038

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC WinCC versions prior to 7.3 Description The issue concerns a hardcoded encryption key in the Project administration application. This allows remote attackers to obtain sensitive information by extracting the key from another...

6.8CVSS0.01087EPSS
SaveExploits0References9
Positive Technologies
Positive Technologies
•added 2013/04/15 12:00 a.m.•27 views

PT-2013-88: Denial of Service in Siemens SIMATIC S7-1200 CPU PLC

The specialists of the Positive Research center have detected a Denial of Service vulnerability in Siemens SIMATIC S7-1200 CPU PLC. An attacker could cause the device to go into defect mode if specially crafted PROFINET packets are sent to the device. A cold restart is required to recover the...

6.1CVSS6.5AI score0.01242EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
•added 2013/04/15 12:00 a.m.•17 views

PT-2013-86: Denial of Service in Siemens SIMATIC S7-1500 CPU PLC

The specialists of the Positive Research center have detected a Denial of Service vulnerability in Siemens SIMATIC S7-1500 CPU PLC. Specially crafted Profinet packets sent to the affected device might cause the device to go into defect mode. A cold restart is required to recover the system. The...

6.1CVSS6.2AI score0.0101EPSS
SaveExploits0References7
Rows per page