4843 matches found
Siemens SIMATIC WinCC (TIA Portal) 13.x < 13 SP1 Upd2 Multiple Vulnerabilities (SSA-487246)
Binary data scadasiemenstiawinccSSA-487246.nbin...
Siemens SIMATIC and SIMATIC WinCC HMI Comfort Panels Denial of Service Vulnerability
Siemens SIMATIC WinCC is a complete Supervisory Control and Data Acquisition SCADA solution for industry, ranging from single-user systems to multi-user systems supporting redundant servers and remote Web client solutions. A security vulnerability in Siemens SIMATIC HMI Comfort Panels WinCC TIA...
Code injection
Siemens SIMATIC HMI Comfort Panels before WinCC TIA Portal 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC TIA Portal 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102...
CVE-2015-2822
Siemens SIMATIC HMI Comfort Panels before WinCC TIA Portal 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC TIA Portal 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102...
CVE-2015-2822
The CVE-2015-2822 issue concerns Siemens SIMATIC HMI/WinCC components vulnerable to remote man-in-the-middle and potential denial-of-service on port 102/TCP. Connected sources specify affected product families and versions, including SIMATIC HMI Comfort Panels and SIMATIC WinCC Runtime Advanced (...
CVE-2015-2823
CVE-2015-2823 affects Siemens SIMATIC HMI/WinCC products (HMI Basic Panels 2nd Gen and others) where an attacker can authenticate remotely by using a password hash instead of the password. The issue is a password-hash authentication weakness that can enable unauthorized access to multiple SAP/Win...
CVE-2015-2822: Improper Input Validation
Siemens SIMATIC HMI Comfort Panels before WinCC TIA Portal 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC TIA Portal 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102...
PT-2015-5915
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC HMI Comfort Panels versions prior to WinCC TIA Portal 13 SP1 Upd2 Siemens SIMATIC WinCC Runtime Advanced versions prior to WinCC TIA Portal 13 SP1 Upd2 Description The issue allows man-in-the-middle attackers to cause a denial ...
CVE-2015-2823: Improper Authentication
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC TIA Portal 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC TIA Portal 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC TIA Portal 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC TIA Portal 13 SP1 Upd2, SIMATIC...
PT-2015-1807
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC HMI Basic Panels 2nd Generation versions prior to WinCC TIA Portal 13 SP1 Upd2 Siemens SIMATIC HMI Comfort Panels versions prior to WinCC TIA Portal 13 SP1 Upd2 Siemens SIMATIC WinCC Runtime Advanced versions prior to WinCC TIA...
CVE-2015-1602
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext 1 protection-level passwords or 2 web-server passwords by leveraging the ability to read these files...
CVE-2015-1601
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors...
Default credentials
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext 1 protection-level passwords or 2 web-server passwords by leveraging the ability to read these files...
Information disclosure
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors...
CVE-2015-1601
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors...
CVE-2015-1602
Siemens SIMATIC STEP 7 TIA Portal 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext 1 protection-level passwords or 2 web-server passwords by leveraging the ability to read these files...
CVE-2015-1601
CVE-2015-1601 affects Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1. The root cause is a man-in-the-middle vulnerability in network communications (Port 102/TCP) that can allow attackers to intercept or modify transmitted data, potentially exposing sensitive information or enab...
CVE-2015-1602
Siemens SIMATIC STEP 7 (TIA Portal) v12 and v13 prior to SP1 Upd1 are affected by CVE-2015-1602, which involves storing cleartext passwords in project files, enabling local attackers to reconstruct protection-level and web-server passwords from read files. The issue comprises two related weakness...
PT-2015-5381
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC STEP 7 TIA Portal versions 12 and 13 before 13 SP1 Upd1 Description The issue allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors. Recommendations For versions 1...
PT-2015-5382
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC STEP 7 TIA Portal versions 12 and 13 before 13 SP1 Upd1 Description The issue improperly stores password data within project files. This makes it easier for local users to determine cleartext protection-level passwords or...