330 matches found
CVE-2016-4785
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens SIPROTEC 4 and SIPROTEC Information Disclosure Vulnerability (CNVD-2016-03386)
Siemens SIPROTEC 4 is a series of multifunctional relays; SIPROTEC Compact is a microcomputer protection device. An information disclosure vulnerability exists in the integrated web server of the SIPROTEC 4 and SIPROTEC Compact. A remote attacker with network access could exploit this vulnerabili...
Siemens SIPROTEC Information Disclosure Vulnerabilities (Update B)
1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION : Exploitable remotely/low skill level to exploit Vendor : Siemens Equipment : SIPROTEC 4 and SIPROTEC Compact Vulnerabilities : Information Exposure 2. UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-16-140-02...
PT-2018-04: Sensitive Information Disclosure in Siemens SIPROTEC 4 and SIPROTEC Compact relays
The specialists of the Positive Research center have detected a Sensitive Information Disclosure vulnerability in Siemens SIPROTEC 4 and SIPROTEC Compact relays. Vulnerability allows unauthenticated remote, low-skilled attackers to upload a modified device configuration overwriting access...
Siemens SIPROTEC 4和SIPROTEC Compact EN100模块拒绝服务漏洞
No description provided by source...
Siemens multiple products there is a security problem, the part of the patch has been released-vulnerability warning-the black bar safety net
Siemens recently released software and firmware security update, saying the company multiple products there are security issues, users are advised to update ASAP. ICS-CERT and Siemens announcement that the SIPROTEC 4 and SIPROTEC Compact devices recently have been affected by the vulnerability...
Siemens SIPROTEC 4 Denial of Service Vulnerability
SIPROTEC 4 and SIPROTEC devices offer a wide range of integrated protection, control, measurement and power substation automation functions; EN100 modules are used to implement IEC 61850 communication. SIPROTEC 4 has been disclosed to have a denial of service vulnerability, which can be exploited...
CVE-2015-5374
CVE-2015-5374 affects Siemens SIPROTEC 4/Compact devices with EN100 Ethernet modules (PROFINET IO, Modbus TCP, DNP3 TCP, IEC 104 firmware) and SIPROTEC 6MU80 integration. The flaw is an improper input validation that allows specially crafted UDP packets to port 50000 to cause a denial-of-service,...
Siemens SIPROTEC Denial-of-Service Vulnerability
OVERVIEW Siemens has identified a denial-of-service vulnerability in the SIPROTEC 4 and SIPROTEC Compact devices. This vulnerability was reported directly to Siemens by Victor Nikitin from i‑Grids LLC Russia. Siemens has produced a new firmware update to mitigate this vulnerability. This...
PT-2015-1513
Name of the Vulnerable Software and Affected Versions Firmware variant PROFINET IO for EN100 Ethernet module versions prior to V1.04.01 Firmware variant Modbus TCP for EN100 Ethernet module versions prior to V1.11.00 Firmware variant DNP3 TCP for EN100 Ethernet module versions prior to V1.03...