Siemens SIPROTEC 5 Devices
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2022-45044
A vulnerability has been identified in SIPROTEC 5 6MD84 CP300 All versions V9.50, SIPROTEC 5 6MD85 CP200 All versions, SIPROTEC 5 6MD85 CP300 All versions V9.50, SIPROTEC 5 6MD86 CP200 All versions, SIPROTEC 5 6MD86 CP300 All versions V9.50, SIPROTEC 5 6MD89 CP300 All versions V9.64, SIPROTEC 5...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in Mendix, among others, Nucleus NET, RUGGEDCOM, SCALANCE, SICAM, SIMATIC, SIPROTEC and SIMATIC WinCC-OA. The vulnerabilities allow a malicious potentially able to launch attacks that result in the following categories of damage: Cross-Site Request Forgery XSRF...
Siemens SIPROTEC 4, SIPROTEC Compact, and Reyrolle Devices using the EN100 Ethernet Communication Module Extension Missing Authentication For Critical Function (CVE-2018-4838)
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module DNP3 variant All versions V1.04, EN100 Ethernet module PROFINET IO variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module IEC 104...
Siemens SIPROTEC 5 and DIGSI 5 Improper Input Validation (CVE-2019-10931)
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules All versions , DIGSI 5 engineering software All versions V7.90, SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87,...
Siemens SIPROTEC Information Disclosure (CVE-2016-4784)
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays Improper Input Validation (CVE-2018-16563)
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...
Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module Inadequate Encryption Strength (CVE-2018-4839)
A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...
Siemens SIPROTEC 5 Improper Input Validation (CVE-2021-37206)
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 All versions V8.80, SIPROTEC 5 relays with CPU variants CP100 All versions V8.80, SIPROTEC 5 relays with CPU variants CP300 All versions V8.80. Received webpackets are not properly processed. An unauthenticated remot...
Siemens Reyrolle Improper Authentication (CVE-2016-7114)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01;Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104 f...
Siemens SIPROTEC Information Disclosure (CVE-2016-4785)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens SIPROTEC 5 and DIGSI 5 Improper Input Validation (CVE-2019-10930)
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules All versions , DIGSI 5 engineering software All versions V7.90, SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87,...
Siemens SIPROTEC 5 relays Buffer Copy Without Checking Size of Input (CVE-2021-33719)
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 All versions V8.80, SIPROTEC 5 relays with CPU variants CP100 All versions V8.80, SIPROTEC 5 relays with CPU variants CP300 All versions V8.80. Specially crafted packets sent to port 4443/tcp could cause a...
Siemens SIPROTEC 5 relays Buffer Copy Without Checking Size of Input (CVE-2021-33720)
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 All versions V8.80, SIPROTEC 5 relays with CPU variants CP100 All versions V8.80, SIPROTEC 5 relays with CPU variants CP300 All versions V8.80. Specially crafted packets sent to port 4443/tcp could cause a...
Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module Missing Authentication For Critical Function (CVE-2018-4840)
A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...
Siemens EN100 Ethernet module & SIPROTEC Merging Unit Denial of Service (CVE-2015-5374)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens SIPROTEC 5 Information Disclosure Vulnerability
SIPROTEC 5 devices offer a range of functions for integrating protection, control, measurement and automation in substations and other applications. An information disclosure vulnerability exists in Siemens SIPROTEC 5, which can be exploited by an attacker to read device information...
CVE-2021-41769
A vulnerability has been identified in SIPROTEC 5 6MD85 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MD86 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MD89 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MU85 devices CPU variant CP300 All versions V8.83, SIPROT...
CVE-2021-41769
A vulnerability has been identified in SIPROTEC 5 6MD85 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MD86 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MD89 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MU85 devices CPU variant CP300 All versions V8.83, SIPROT...
Input validation
A vulnerability has been identified in SIPROTEC 5 6MD85 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MD86 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MD89 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MU85 devices CPU variant CP300 All versions V8.83, SIPROT...