Lucene search
+L

218 matches found

ICS
ICS
added 2013/12/22 7:0 a.m.73 views

Siemens WinCC 7.0 SP3 Multiple Vulnerabilities

Overview This advisory provides mitigation details for vulnerabilities that impact the Siemens SIMATIC WinCC. Positive Technologies and Siemens ProductCERT have identified multiple vulnerabilities in the Siemens SIMATIC WinCC, which is used to configure SIMATIC operator devices. Siemens has...

6.8CVSS8.6AI score0.03361EPSS
SaveExploits0References10
Positive Technologies
Positive Technologies
added 2013/12/01 12:0 a.m.14 views

PT-2013-78: Buffer overflow in SIMATIC WinCC Open Architecture

The specialists of the Positive Research center have detected a Buffer overflow vulnerability in SIMATIC WinCC Open Architecture. The SIMATIC WinCC OA integrated Web server at Port 4999/TCP might allow attackers to perform remote code execution by sending specially crafted packets without...

9.3CVSS7.8AI score0.05261EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
added 2013/12/01 12:0 a.m.17 views

PT-2013-80: Improper input validation in SIMATIC WinCC Open Architecture

The specialists of the Positive Research center have detected an Improper input validation vulnerability in SIMATIC WinCC Open Architecture. The SIMATIC WinCC OA integrated Web server at Port 4999/TCP might allow attackers to perform a denial of service attack on the SIMATIC WinCC OA monitoring...

5CVSS6.7AI score0.02142EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
added 2013/12/01 12:0 a.m.12 views

PT-2013-79: Relative path traversal in SIMATIC WinCC Open Architecture

The specialists of the Positive Research center have detected a Relative path traversal vulnerability in SIMATIC WinCC Open Architecture. The SIMATIC WinCC OA integrated Web server at Port 4999/TCP might allow attackers to traverse through the server’s file system based on the application’s Windo...

5CVSS6.7AI score0.03507EPSS
SaveExploits0References5
Packet Storm
Packet Storm
added 2013/01/21 12:0 a.m.36 views

Simatic WinCC Information Harvester

encoding: UTF-8 This file is part of the Metasploit Framework and may be subject to redistribution and commercial restrictions. Please see the Metasploit web site for more information on licensing and terms of use. http://metasploit.com/ require 'msf/core' class Metasploit3 'Simatic WinCC info...

7.4AI score
SaveExploits0
Positive Technologies
Positive Technologies
added 2012/12/23 12:0 a.m.14 views

PT-2014-12: Information Disclosure in Siemens SIMATIC WinCC

The specialists of the Positive Research center have detected an Information disclosure vulnerability in SIMATIC WinCC. The SIMATIC WinCC WebNavigator server at port 80/tcp and port 443/tcp could allow unauthenticated access to sensitive data if an attacker sends specially crafted HTTP requests t...

5CVSS6.4AI score0.01686EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2012/09/21 12:0 a.m.14 views

PT-2013-31: Cross-Site Scripting in Siemens Simatic WinCC TIA Portal

The specialists of the Positive Research center have detected "Cross-Site Scripting" vulnerability in Siemens Simatic WinCC TIA Portal. The HMI’s web application is susceptible to stored Cross-Site-Scripting attacks. An authenticated user may store data on the web application, which will execute...

4CVSS6.4AI score0.01196EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2012/09/21 12:0 a.m.19 views

PT-2015-12: Privilege Gaining in Siemens SIMATIC WinCC (TIA Portal)

The specialists of the Positive Research center have detected a Privilege Gaining vulnerability in Siemens SIMATIC WinCC TIA Portal. Vulnerability exists due to a hard coded encryption key in WinCC RT Professional, which allows remote attackers to obtain sensitive information and escalate their...

6.8CVSS6.4AI score0.01087EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2012/09/21 12:0 a.m.17 views

PT-2013-30: Denial of Service in Siemens Simatic WinCC TIA Portal

The specialists of the Positive Research center have detected "Denial of Service" vulnerability in Siemens Simatic WinCC TIA Portal. By manipulating HTTP requests an authenticated attacker may crash the HMI’s web application. The web application will become unavailable until the device is...

4CVSS6.4AI score0.0183EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2012/09/21 12:0 a.m.17 views

PT-2013-33: CRLF Injection in Siemens Simatic WinCC TIA Portal

The specialists of the Positive Research center have detected "CRLF Injection" vulnerability in Siemens Simatic WinCC TIA Portal. If a user clicks on a malicious link which seems to lead to a HMI web application, it is possible to display any data to the user HTTP response splitting. How to fix...

4.3CVSS6.5AI score0.01539EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2012/09/21 12:0 a.m.15 views

PT-2013-34: Cross-Site Scripting in Siemens Simatic WinCC TIA Portal

The specialists of the Positive Research center have detected "Cross-Site Scripting" vulnerability in Siemens Simatic WinCC TIA Portal. If a user clicks on a malicious link which seems to lead to a HMI web application, it is possible to display any data to the user server-side script injection. H...

4.3CVSS6.5AI score0.01513EPSS
SaveExploits0References4
OpenVAS
OpenVAS
added 2012/09/20 12:0 a.m.94 views

Siemens SIMATIC WinCC HMI Web Server Multiple Input Validation Vulnerabilities - Active Check

Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. SPDX-FileCopyrightText: 2012 Greenbone AG Some text descriptions might be excerpted from...

8.5CVSS6.4AI score0.12545EPSS
SaveExploits1References4
Positive Technologies
Positive Technologies
added 2012/08/02 12:0 a.m.16 views

PT-2013-50: Cross-Site Request Forgery (CSRF) in Siemens Simatic WinCC TIA Portal

The specialists of the Positive Research center have detected "Cross-Site Request Forgery" vulnerability in Siemens Simatic WinCC TIA Portal. Cross-site request forgery CSRF vulnerability in Siemens WinCC TIA Portal allows remote attackers to hijack the authentication of unspecified victims by...

6.8CVSS7.3AI score0.0108EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2012/07/11 12:0 a.m.15 views

PT-2013-27: Directory Traversal in Siemens Simatic WinCC and PCS 7

The specialists of the Positive Research center have detected "Directory Traversal" vulnerability in Siemens Simatic WinCC and PCS 7. Authenticated users may manipulate the URL in the web browser to access the file system of the web server. With this vulnerability they may read all the files that...

4CVSS6.5AI score0.02328EPSS
SaveExploits0References6
securityvulns
securityvulns
added 2011/12/05 12:0 a.m.78 views

Vulnerabilities in Siemens SIMATIC WinCC flexible 2008 SP2

Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2 + security patch 1 Platforms: Windows Bugs: A HmiLoad strings sta...

1.6AI score
SaveExploits0
securityvulns
securityvulns
added 2011/12/05 12:0 a.m.30 views

Siemens SIMATIC WinCC flexible multiple security vulnerabilities

HmiLoad and miniweb multiple security vulnerabilities...

1.6AI score
SaveExploits0References1Affected Software1
exploitpack
exploitpack
added 2011/11/28 12:0 a.m.42 views

Siemens SIMATIC WinCC Flexible (Runtime) - Multiple Vulnerabilities

Siemens SIMATIC WinCC Flexible Runtime - Multiple Vulnerabilities Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2...

0.5AI score
SaveExploits0
ATTACKERKB
ATTACKERKB
added 2010/07/22 12:0 a.m.61 views

CVE-2010-2772

Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568. Recent assessments: Assessed Attacker...

9.3CVSS5.5AI score0.91324EPSS
SaveIn wildExploits16References15
Rows per page
Query Builder