Lucene search
+L

2411 matches found

Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•33 views

Siemens Multiple Devices Profinet DCP Denial of Service

Binary data 720111.prm...

7.1CVSS7AI score0.00906EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•32 views

Siemens Multiple Devices Profinet DCP Denial of Service

Binary data 720110.prm...

7.1CVSS7AI score0.01149EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•24 views

Siemens Multiple Devices Remote Code Execution

Binary data 720142.prm...

8.8CVSS7.3AI score0.00954EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•34 views

Siemens SCALANCE X200 IRT Switches < 5.1.0 SNMP Command Execution

Binary data 720038.prm...

7.5CVSS7.3AI score0.01445EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•19 views

Siemens SCALANCE S602, S612, S623, S627-2M < 4.0.1.1 Cross-Site Scripting (XSS)

Binary data 720169.prm...

5.4CVSS7.3AI score0.00689EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2019/04/23 12:00 a.m.•22 views

The vulnerability of Scalance X industrial switches lies in the insufficient validation of input data, which allows attackers to bypass network firewalls.

The vulnerability of Scalance X industrial switches is related to insufficient verification of input data. Exploiting this vulnerability can allow a remote attacker to bypass network firewalls by transmitting malicious packets into the mirrored network...

9.1CVSS7.8AI score0.01328EPSS
SaveExploits0References2Affected Software4
ICS
ICS
•added 2019/04/09 12:00 p.m.•64 views

Siemens SCALANCE, SIMATIC, RUGGEDCOM, and SINAMICS Products (Update F)

1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION : Exploitable remotely/low skill level to exploit/public exploits are available. Vendor : Siemens Equipment : SCALANCE, SIMATIC, RUGGEDCOM, and SINAMICS Products Vulnerabilities : Security Features 2. UPDATE INFORMATION This updated advisory is a...

8.1CVSS8AI score0.04575EPSS
SaveExploits1References55
ICS
ICS
•added 2019/04/09 12:00 a.m.•117 views

Siemens SCALANCE and SIMATIC libcurl (Update B)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE and SIMATIC Vulnerability: Out-of-bounds Read 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-21-068-10 Siemens SCALANCE and...

7.5CVSS7.7AI score0.04286EPSS
SaveExploits1References9
CNVD
CNVD
•added 2019/03/13 12:00 a.m.•12 views

Multiple SCALANCE X switches products mirror port isolation vulnerability

SCALANCE X switches are used to connect industrial components such as programmable logic controllers PLCs or human machine interfaces HMIs. A mirror port isolation vulnerability exists in several SCALANCE X switches products. The vulnerability is due to the monitoring barriers on the affected...

9.1CVSS6.9AI score0.01328EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2019/03/12 12:00 a.m.•4 views

PT-2019-1886

Name of the Vulnerable Software and Affected Versions Scalance X affected versions not specified Description The issue is related to insufficient monitoring barrier in the affected products, allowing data to be forwarded over the mirror port into the mirrored network. This behavior can be exploit...

9.1CVSS0.01328EPSS
SaveExploits0References4
ICS
ICS
•added 2019/03/12 12:00 a.m.•370 views

Siemens SCALANCE X (Update D)

1. EXECUTIVE SUMMARY CVSS v3 5.4 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SCALANCE X Vulnerability: Expected Behavior Violation 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-19-085-01 Siemens SCALANCE X Update C that was published...

9.1CVSS9.3AI score0.01328EPSS
SaveExploits0References11
BDU FSTEC
BDU FSTEC
•added 2019/01/18 12:00 a.m.•12 views

The vulnerability of Siemens SCALANCE S network gateways’ microprogramming software is related to insufficient protection of the WEB-page structure, allowing attackers to carry out cross-site scripting attacks.

The vulnerability of Siemens SCALANCE S network gateways’ microprogramming software is related to insufficient protection of the web page structure. Exploiting this vulnerability allows a remote attacker to perform cross-site scripting attacks...

4.7CVSS5.7AI score0.00689EPSS
SaveExploits0References3
OSV
OSV
•added 2018/12/13 4:29 p.m.•15 views

CVE-2018-16555

A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...

5.4CVSS5.7AI score0.00689EPSS
SaveExploits0References2
Prion
Prion
•added 2018/12/13 4:29 p.m.•25 views

Cross site scripting

A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...

3.5CVSS5AI score0.00689EPSS
SaveExploits0References2Affected Software4
NVD
NVD
•added 2018/12/13 4:29 p.m.•27 views

CVE-2018-16555

A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...

5.4CVSS5.1AI score0.00689EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2018/12/13 4:00 p.m.•34 views

CVE-2018-16555

A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...

5.1AI score0.00689EPSS
SaveExploits0References2
CVE
CVE
•added 2018/12/13 4:00 p.m.•74 views

CVE-2018-16555

CVE-2018-16555 affects Siemens SCALANCE S602, S612, S623 and S627-2M (all versions before 4.0.1.1). The vulnerability is an improper neutralization of input during web page generation, enabling cross-site scripting (XSS) if a user, who must be logged into the web interface, is tricked into clicki...

5.4CVSS5.1AI score0.00689EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/13 12:00 a.m.•5 views

CVE-2018-16555: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)

A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...

5.4CVSS5.6AI score0.00689EPSS
SaveExploits0References3
CNVD
CNVD
•added 2018/11/16 12:00 a.m.•14 views

Multiple Siemens Products Cross-Site Scripting Vulnerabilities

Siemens SCALANCE S602 and others are Ethernet security modules from Siemens, Germany. A cross-site scripting vulnerability exists in several Siemens products, which can be exploited by remote attackers to inject arbitrary scripts via malicious links...

5.4CVSS5.3AI score0.00689EPSS
SaveExploits0References1
ThreatPost
ThreatPost
•added 2018/11/14 5:40 p.m.•40 views

Siemens Patches Firewall Flaw That Put Operations at Risk

Siemens AG on Tuesday issued a slew of fixes addressing eight vulnerabilities spanning its industrial product lines. The most serious of the patched flaws include a cross-site scripting vulnerability in Siemens’ SCALANCE firewall product. The flaw could allow an attacker to gain unauthorized acce...

9.3CVSS0.2AI score0.02656EPSS
SaveExploits0References8
Rows per page
Query Builder