CVE-2022-34821
A vulnerability has been identified in RUGGEDCOM RM1224 LTE4G EU 6GK6108-4AM00-2BA2, RUGGEDCOM RM1224 LTE4G NAM 6GK6108-4AM00-2DA2, SCALANCE M804PB 6GK5804-0AP00-2AA2, SCALANCE M812-1 ADSL-Router 6GK5812-1AA00-2AA2, SCALANCE M812-1 ADSL-Router 6GK5812-1BA00-2AA2, SCALANCE M816-1 ADSL-Router...
The vulnerability of the OSPF network protocol implementation in the microcomputer-based switching devices SCALANCE of the XM-400 and XR-500 series allows a intruder to trigger a service failure.
The vulnerability of the OSPF network protocol implementation in the microcomputer-based switching devices SCALANCE models XM-400 and XR-500 is related to the lack of integrity checks. Exploiting this vulnerability can allow a malicious actor to cause service interruptions remotely...
SIEMENS SCALANCE XM-400 and XR-500 OSPF Packet Processing Vulnerability
SCALANCE X switches are used to connect industrial components such as programmable logic controllers PLCs or human machine interfaces HMIs. An OSPF packet handling vulnerability exists in the SIEMENS SCALANCE XM-400 and XR-500, which stems from the implementation of the OSPF protocol in the devic...
CVE-2021-37182
A vulnerability has been identified in SCALANCE XM408-4C All versions V6.5, SCALANCE XM408-4C L3 int. All versions V6.5, SCALANCE XM408-8C All versions V6.5, SCALANCE XM408-8C L3 int. All versions V6.5, SCALANCE XM416-4C All versions V6.5, SCALANCE XM416-4C L3 int. All versions V6.5, SCALANCE...
CVE-2021-37182
A vulnerability has been identified in SCALANCE XM408-4C All versions V6.5, SCALANCE XM408-4C L3 int. All versions V6.5, SCALANCE XM408-8C All versions V6.5, SCALANCE XM408-8C L3 int. All versions V6.5, SCALANCE XM416-4C All versions V6.5, SCALANCE XM416-4C L3 int. All versions V6.5, SCALANCE...
Design/Logic Flaw
A vulnerability has been identified in SCALANCE XM408-4C All versions V6.5, SCALANCE XM408-4C L3 int. All versions V6.5, SCALANCE XM408-8C All versions V6.5, SCALANCE XM408-8C L3 int. All versions V6.5, SCALANCE XM416-4C All versions V6.5, SCALANCE XM416-4C L3 int. All versions V6.5, SCALANCE...
CVE-2021-37182
CVE-2021-37182 affects Siemens SCALANCE XM/XR family with versions
CVE-2021-37182
A vulnerability has been identified in SCALANCE XM408-4C All versions V6.5, SCALANCE XM408-4C L3 int. All versions V6.5, SCALANCE XM408-8C All versions V6.5, SCALANCE XM408-8C L3 int. All versions V6.5, SCALANCE XM416-4C All versions V6.5, SCALANCE XM416-4C L3 int. All versions V6.5, SCALANCE...
CVE-2021-37182: Improper Validation of Integrity Check Value
A vulnerability has been identified in SCALANCE XM408-4C All versions V6.5, SCALANCE XM408-4C L3 int. All versions V6.5, SCALANCE XM408-8C All versions V6.5, SCALANCE XM408-8C L3 int. All versions V6.5, SCALANCE XM416-4C All versions V6.5, SCALANCE XM416-4C L3 int. All versions V6.5, SCALANCE...
Siemens SCALANCE XM-400 and XR-500
1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SCALANCE XM-400 and XR-500 Vulnerability: Improper Validation of Integrity Check Value 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to...
PT-2022-3404
Name of the Vulnerable Software and Affected Versions SCALANCE XM408-4C versions prior to V6.5 SCALANCE XM408-4C L3 int. versions prior to V6.5 SCALANCE XM408-8C versions prior to V6.5 SCALANCE XM408-8C L3 int. versions prior to V6.5 SCALANCE XM416-4C versions prior to V6.5 SCALANCE XM416-4C L3...
Siemens SCALANCE 安全漏洞
SCALANCE X switches are used to connect industrial components such as programmable logic controllers PLCs or human machine interfaces HMIs. An OSPF packet handling vulnerability exists in the SIEMENS SCALANCE XM-400 and XR-500, which stems from the implementation of the OSPF protocol in the devic...
Vulnerability fixed in Siemens SCALANCE
A vulnerability has been fixed in Siemens SCALANCE. The vulnerability allows an unauthenticated remote malicious person capable of causing a denial-of-service. Siemens has released updates to fix the vulnerability. More information can be found on the page below:...
Siemens SCALANCE LPE9403 Third-Party Vulnerabilities
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely, low attack complexity Vendor: Siemens Equipment: SCALANCE LPE9403 Vulnerabilities: Multiple 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause crashes and unrestricted file access, impacting the...
Siemens SCALANCE LPE 4903 and SINUMERIK Edge
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SCALANCE LPE 4903 and SINUMERIK Edge Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unprivileged local user to escalate privileges and...
The vulnerability of the microprogramming software in industrial switches SCALANCE X302-7 EEC, SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-4M EEC, SCALANCE XR324-4M PoE, SCALANCE XR324-12M, SCALANCE XR324-12M TS, and SIPLUS NET SCALANCE X308-2. This vulnerability is related to the failure to eliminate HTML tags related to scripts on web pages, allowing attackers to perform cross-site scripting attacks.
The vulnerability of the microprogrammed software in industrial switches SCALANCE X302-7 EEC, SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE...
Siemens Industrial Devices using libcurl
1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: Industrial devices using libcurl Vulnerabilities: Use After Free 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-22-132-13 Siemens Industrial Devices using...
Siemens SIMATIC NET CP, SINEMA & SCALANCE Integer Overflow (CVE-2021-41991)
The in-memory certificate cache in strongSwan before 5.9.4 has a remote integer overflow upon receiving many requests with different certificates to fill the cache and later trigger the replacement of cache entries. The code attempts to select a less-often-used cache entry by means of a random...
Siemens SCALANCE W-1700 (11ac) Series Denial of Service Vulnerability
The SCALANCE W-1700 products are IEEE 802.11 compliant wireless communication devices. a denial of service vulnerability exists in the Siemens SCALANCE W-1700 11ac series, which can be exploited by attackers to trigger a denial of service condition...
Siemens SCALANCE W-1700 (11ac) Series Denial of Service Vulnerability (CNVD-2022-28498)