Lucene search
+L

2220 matches found

CVE
CVE
added 2022/04/12 9:8 a.m.88 views

CVE-2022-27481

CVE-2022-27481 affects Siemens SCALANCE W1788-1 M12, W1788-2 EEC M12, W1788-2 M12, and W1788-2IA M12 (all versions before 3.0.0). The vulnerability arises from improper handling of ARP request resources, enabling a race condition that can crash the entire device. Attached Red Hat/CISA/ICS and oth...

5.7CVSS5.1AI score0.00232EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/04/12 9:8 a.m.32 views

CVE-2022-27481

A vulnerability has been identified in SCALANCE W1788-1 M12 All versions V3.0.0, SCALANCE W1788-2 EEC M12 All versions V3.0.0, SCALANCE W1788-2 M12 All versions V3.0.0, SCALANCE W1788-2IA M12 All versions V3.0.0. Affected devices do not properly handle resources of ARP requests. This could allow ...

5.4AI score0.00232EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:7 a.m.112 views

CVE-2022-26380

CVE-2022-26380 affects Siemens SCALANCE X-300/ XR324/ XR324-12M family and related X-30x devices. A SNMP handling flaw allows an unauthenticated attacker to trigger a reboot by requesting specific SNMP information due to improper validation of SNMP keys (out-of-bounds read). Impact is reboot unle...

7.8CVSS7.3AI score0.00932EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/04/12 9:7 a.m.39 views

CVE-2022-26335

A vulnerability has been identified in SCALANCE X302-7 EEC 230V, SCALANCE X302-7 EEC 230V, coated, SCALANCE X302-7 EEC 24V, SCALANCE X302-7 EEC 24V, coated, SCALANCE X302-7 EEC 2x 230V, SCALANCE X302-7 EEC 2x 230V, coated, SCALANCE X302-7 EEC 2x 24V, SCALANCE X302-7 EEC 2x 24V, coated, SCALANCE...

7.8AI score0.01364EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:7 a.m.98 views

CVE-2022-26335

CVE-2022-26335 affects Siemens SCALANCE X switch family (e.g., X302-7 X304-2FE, X307-2/3, X308-2/4M/XR324 series, SIPLUS NET variants). Affected devices do not properly validate the URI of incoming HTTP GET requests, allowing an unauthenticated remote attacker to crash the device. Reported affect...

7.8CVSS7.5AI score0.01364EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/04/12 9:7 a.m.27 views

CVE-2022-26334

A vulnerability has been identified in SCALANCE X302-7 EEC 230V, SCALANCE X302-7 EEC 230V, coated, SCALANCE X302-7 EEC 24V, SCALANCE X302-7 EEC 24V, coated, SCALANCE X302-7 EEC 2x 230V, SCALANCE X302-7 EEC 2x 230V, coated, SCALANCE X302-7 EEC 2x 24V, SCALANCE X302-7 EEC 2x 24V, coated, SCALANCE...

7.8AI score0.01364EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:7 a.m.111 views

CVE-2022-26334

This CVE (CVE-2022-26334) is a buffer copy without checking size in Siemens SCALANCE X-300/XR324 family devices, triggered by unauthenticated HTTP GET requests that fail to validate the XNo parameter, leading to a device crash. Affected products include numerous SCALANCE X switch models (X302-7, ...

7.8CVSS7.5AI score0.01364EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/04/12 9:7 a.m.28 views

CVE-2022-25756

A vulnerability has been identified in SCALANCE X302-7 EEC 230V, SCALANCE X302-7 EEC 230V, coated, SCALANCE X302-7 EEC 24V, SCALANCE X302-7 EEC 24V, coated, SCALANCE X302-7 EEC 2x 230V, SCALANCE X302-7 EEC 2x 230V, coated, SCALANCE X302-7 EEC 2x 24V, SCALANCE X302-7 EEC 2x 24V, coated, SCALANCE...

6AI score0.00553EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:7 a.m.125 views

CVE-2022-25756

CVE-2022-25756 affects Siemens SCALANCE X-300 switch family devices (various models listed in the vulnerability entry). The issue is a Cross-Site Scripting (XSS) vulnerability in the device’s integrated web server, caused by improper neutralization of script-related HTML tags. An attacker could t...

6.1CVSS5.8AI score0.00553EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/04/12 9:7 a.m.30 views

CVE-2022-25755

A vulnerability has been identified in SCALANCE X302-7 EEC 230V, SCALANCE X302-7 EEC 230V, coated, SCALANCE X302-7 EEC 24V, SCALANCE X302-7 EEC 24V, coated, SCALANCE X302-7 EEC 2x 230V, SCALANCE X302-7 EEC 2x 230V, coated, SCALANCE X302-7 EEC 2x 24V, SCALANCE X302-7 EEC 2x 24V, coated, SCALANCE...

7.6AI score0.01308EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:7 a.m.101 views

CVE-2022-25755

Siemens SCALANCE X-300/XR3xx family devices are affected by CVE-2022-25755 due to the webserver missing specific security headers, enabling an unauthenticated remote attacker to potentially extract confidential session information under certain circumstances. Affected models span SCALANCE X302-7/...

7.5CVSS7.3AI score0.01308EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2022/04/12 9:7 a.m.111 views

CVE-2022-25754

CVE-2022-25754 affects Siemens SCALANCE X-300 switches and related models (web server on affected devices). The issue arises from the integrated web server, which could allow remote attackers to perform actions with the permissions of a victim user if the victim has an active session and is lured...

8.8CVSS8.5AI score0.00525EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/04/12 9:7 a.m.31 views

CVE-2022-25754

A vulnerability has been identified in SCALANCE X302-7 EEC 230V, SCALANCE X302-7 EEC 230V, coated, SCALANCE X302-7 EEC 24V, SCALANCE X302-7 EEC 24V, coated, SCALANCE X302-7 EEC 2x 230V, SCALANCE X302-7 EEC 2x 230V, coated, SCALANCE X302-7 EEC 2x 24V, SCALANCE X302-7 EEC 2x 24V, coated, SCALANCE...

8.8AI score0.00525EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/04/12 9:7 a.m.32 views

CVE-2022-25753

A vulnerability has been identified in SCALANCE X302-7 EEC 230V, SCALANCE X302-7 EEC 230V, coated, SCALANCE X302-7 EEC 24V, SCALANCE X302-7 EEC 24V, coated, SCALANCE X302-7 EEC 2x 230V, SCALANCE X302-7 EEC 2x 230V, coated, SCALANCE X302-7 EEC 2x 24V, SCALANCE X302-7 EEC 2x 24V, coated, SCALANCE...

9AI score0.01637EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:7 a.m.99 views

CVE-2022-25753

CVE-2022-25753 is a stack-based buffer overflow vulnerability in the CLI handling of arguments such as IP addresses on Siemens SCALANCE X-300/XR/X-308 family devices. The issue could allow an authenticated remote attacker to execute arbitrary code on affected devices. Affected products include a ...

8.8CVSS8.8AI score0.01637EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/04/12 9:7 a.m.33 views

CVE-2022-25752

A vulnerability has been identified in SCALANCE X302-7 EEC 230V, SCALANCE X302-7 EEC 230V, coated, SCALANCE X302-7 EEC 24V, SCALANCE X302-7 EEC 24V, coated, SCALANCE X302-7 EEC 2x 230V, SCALANCE X302-7 EEC 2x 230V, coated, SCALANCE X302-7 EEC 2x 24V, SCALANCE X302-7 EEC 2x 24V, coated, SCALANCE...

9.6AI score0.01431EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:7 a.m.108 views

CVE-2022-25752

CVE-2022-25752 relates to Siemens SCALANCE X-300/XR324 series devices where the webserver counts and uses session IDs/nonces insecurely. This design flaw could let an unauthenticated remote attacker brute‑force session IDs and hijack existing sessions, potentially affecting a wide range of SCALAN...

9.8CVSS9.3AI score0.01431EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/04/12 9:7 a.m.36 views

CVE-2022-25751

A vulnerability has been identified in SCALANCE X302-7 EEC 230V, SCALANCE X302-7 EEC 230V, coated, SCALANCE X302-7 EEC 24V, SCALANCE X302-7 EEC 24V, coated, SCALANCE X302-7 EEC 2x 230V, SCALANCE X302-7 EEC 2x 230V, coated, SCALANCE X302-7 EEC 2x 24V, SCALANCE X302-7 EEC 2x 24V, coated, SCALANCE...

7.8AI score0.01364EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:7 a.m.106 views

CVE-2022-25751

CVE-2022-25751 affects Siemens SCALANCE X-300/XR324/X408-2/X320 etc. devices; root cause is improper validation of HTTP headers in the embedded web server, enabling an unauthenticated remote attacker to crash affected devices. Affected families include X-302/X-304/X-306/X-307/X-308/X-310/X-320/XR...

7.8CVSS7.5AI score0.01364EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2022/04/12 12:0 a.m.6 views

多款 Siemens 产品跨站请求伪造漏洞

SCALANCE X switches are used to connect industrial components such as programmable logic controllers PLCs or human-machine interfaces HMIs.SIPLUS extreme is designed for reliable operation under extreme conditions.A cross-site request forgery vulnerability exists in Siemens SCALANCE X-300 Switch...

8.8CVSS7.7AI score0.00525EPSS
SaveExploits0References3
Rows per page
Query Builder