7.8 High
CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.9 High
AI Score
Confidence
High
7.2 High
CVSS2
Access Vector
LOCAL
Access Complexity
LOW
Authentication
NONE
Confidentiality Impact
COMPLETE
Integrity Impact
COMPLETE
Availability Impact
COMPLETE
AV:L/AC:L/Au:N/C:C/I:C/A:C
Successful exploitation of this vulnerability could allow an unprivileged local user to escalate privileges and gain administrative rights.
The following products and versions are affected:
A local privilege escalation vulnerability could allow an attacker to craft environment variables and execute arbitrary code. When successfully executed, the attack can cause a local privilege escalation, giving unprivileged users administrative rights on the target machine.
CVE-2021-4034 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
Siemens reported this vulnerability to CISA.
Siemens recommends users update products to the following versions:
Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.
For more information see Siemens Security Advisory SSA-330556
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov/ics in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-4034
cert-portal.siemens.com/productcert/pdf/ssa-330556.pdf
cisa.gov/ics
cisa.gov/ics
cwe.mitre.org/data/definitions/787.html
public.govdelivery.com/accounts/USDHSCISA/subscriber/new?topic_id=USDHSCISA_138
support.industry.siemens.com/cs/ww/en/view/109811123/
twitter.com/CISAgov
twitter.com/intent/tweet?text=Siemens%20SCALANCE%20LPE%204903%20and%20SINUMERIK%20Edge+https://www.cisa.gov/news-events/ics-advisories/icsa-22-167-16
www.cisa.gov/uscert/ics/recommended-practices
www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B
www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
www.dhs.gov
www.dhs.gov/foia
www.dhs.gov/performance-financial-reports
www.facebook.com/CISA
www.facebook.com/sharer/sharer.php?u=https://www.cisa.gov/news-events/ics-advisories/icsa-22-167-16&title=Siemens%20SCALANCE%20LPE%204903%20and%20SINUMERIK%20Edge
www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
www.instagram.com/cisagov
www.linkedin.com/company/cybersecurity-and-infrastructure-security-agency
www.linkedin.com/sharing/share-offsite/?url=https://www.cisa.gov/news-events/ics-advisories/icsa-22-167-16
www.oig.dhs.gov/
www.siemens.com/cert/operational-guidelines-industrial-security
www.siemens.com/industrialsecurity
www.surveymonkey.com/r/CISA-cyber-survey?product=https://www.cisa.gov/news-events/ics-advisories/icsa-22-167-16
www.usa.gov/
www.whitehouse.gov/
www.youtube.com/@cisagov
mailto:?subject=Siemens%20SCALANCE%20LPE%204903%20and%20SINUMERIK%20Edge&body=www.cisa.gov/news-events/ics-advisories/icsa-22-167-16
7.8 High
CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.9 High
AI Score
Confidence
High
7.2 High
CVSS2
Access Vector
LOCAL
Access Complexity
LOW
Authentication
NONE
Confidentiality Impact
COMPLETE
Integrity Impact
COMPLETE
Availability Impact
COMPLETE
AV:L/AC:L/Au:N/C:C/I:C/A:C