2220 matches found
Siemens SCALANCE Improper Input Validation (CVE-2020-26146)
An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non- consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented...
Siemens SCALANCE W1750D Classic Buffer Overflow (CVE-2021-25149)
A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Insta...
Siemens SCALANCE W1750D Command Injection (CVE-2020-24635)
A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aru...
Siemens SCALANCE W1750D Command Injection (CVE-2021-37724)
A remote arbitrary command execution vulnerability was discovered in Aruba Operating System Software versions: Prior to 8.7.1.2, 8.6.0.8, 8.5.0.12, 8.3.0.16. Aruba has released patches for ArubaOS that address this security vulnerability. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE Improper Limitation of a Pathname to a Restricted Directory (CVE-2021-37733)
A remote path traversal vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software versions: Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.1, 8.6.0.7, 8.5.0.11, 8.3.0.16. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address...
Siemens SCALANCE X Switches Protection Mechanism Failure (CVE-2019-13924)
A vulnerability has been identified in SCALANCE S602 All versions V4.1, SCALANCE S612 All versions V4.1, SCALANCE S623 All versions V4.1, SCALANCE S627-2M All versions V4.1, SCALANCE X-200 switch family incl. SIPLUS NET variants All versions 5.2.4, SCALANCE X-200IRT switch family incl. SIPLUS NET...
Siemens SCALANCE Cross-Site Request Forgery (CVE-2019-5318)
A remote cross-site request forgery csrf vulnerability was discovered in Aruba Operating System Software versions: 6.x.x.x: all versions, 8.x.x.x: all versions prior to 8.8.0.0. Aruba has released patches for ArubaOS that address this security vulnerability. This plugin only works with Tenable.ot...
Siemens SCALANCE W1750D Improper Input Validation (CVE-2021-25148)
A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.4 and below. Aruba h...
Siemens SCALANCE Improper Input Validation (CVE-2020-26144)
An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first 8 bytes correspond to a valid RFC1042 i.e., LLC/SNAP header for EAPOL. An adversary can abuse this to inject arbitrary network packets...
Siemens SCALANCE XCM332 Allocation of Resources Without Limits or Throttling (CVE-2022-32205)
A malicious server can serve excessive amounts of Set-Cookie: headers in a HTTP response to curl and curl 7.84.0 stores all of them. A sufficiently large amount of big cookies make subsequent HTTP requests to this, or other servers to which the cookies match, create requests that become larger th...
Siemens SCALANCE W1750D Command Injection (CVE-2021-25146)
A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aru...
Siemens SCALANCE W1750D Improper Input Validation (CVE-2021-25159)
A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below...
Siemens SCALANCE W1750D Improper Input Validation (CVE-2021-25145)
A remote unauthorized disclosure of information vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.1...
Siemens SCALANCE W1750D Command Injection (CVE-2018-7082)
A command injection vulnerability is present in Aruba Instant that permits an authenticated administrative user to execute arbitrary commands on the underlying operating system. A malicious administrator could use this ability to install backdoors or change system configuration in a way that woul...
Siemens SCALANCE M875 Arbitrary File Read and Write (CVE-2018-4861)
A vulnerability has been identified in SCALANCE M875 All versions. An authenticated remote attacker with access to the web interface 443/tcp, could potentially read and download arbitrary files from the device's file system. Successful exploitation requires that the attacker has network access to...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in, among others: TIA Portal, SIPROTEC, SICAM , SCALANCE, SIMANTIC and Mendix. The vulnerabilities potentially enable a malicious party to launch attacks that could result in the following categories of damage: Denial-of-Service DoS. Remote code execution User...
Siemens SCALANCE W1750D Improper Neutralization of Input During Web Page Generation (CVE-2022-37896)
A vulnerability in the Aruba InstantOS and ArubaOS 10 web management interface could allow a remote attacker to conduct a reflected cross- site scripting XSS attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser...
Siemens SCALANCE W1750D Improper Neutralization of Input During Web Page Generation (CVE-2018-7064)
A reflected cross-site scripting XSS vulnerability is present in an unauthenticated Aruba Instant web interface. An attacker could use this vulnerability to trick an IAP administrator into clicking a link which could then take administrative actions on the Instant cluster, or expose the session...
Siemens SCALANCE M875 Insufficiently Protected Credentials (CVE-2018-11449)
A vulnerability has been identified in SCALANCE M875 All versions. An attacker with access to the local file system might obtain passwords for administrative users. Successful exploitation requires read access to files on the local file system. A successful attack could allow an attacker to obtai...
Siemens SCALANCE 加密问题漏洞
Siemens SCALANCE is a series of Ethernet switches from Siemens, Germany. It connects to Industrial Control System ICS devices, including Programmable Logic Controllers PLCs and Human Machine Interface HMI systems. A vulnerability exists in Siemens SCALANCE due to an encryption issue, which arises...