Siemens SCALANCE Improper Limitation of a Pathname to a Restricted Directory (CVE-2021-37729)

A remote path traversal vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software versions: Prior to 8.6.0.0-2.2.0.4; Prior to 8.7.1.3, 8.6.0.9, 8.5.0.12, 8.3.0.16, 6.5.4.19, 6.4.4.25. Aruba has released patches for Aruba SD- WAN Software and Gateways and...

6.5CVSS6.9AI score0.0099EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.24 views

Siemens SCALANCE Cross-Site Request Forgery (CVE-2021-37725)

A remote cross-site request forgery csrf vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software versions: Prior to 8.6.0.4-2.2.0.4; Prior to 8.8.0.1, 8.7.1.2, 8.6.0.8, 8.5.0.12, 8.3.0.15. Aruba has released patches for Aruba SD-WAN Software and Gateway...

8.8CVSS6.8AI score0.00398EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.25 views

Siemens SCALANCE W1700 Improper Input Validation (CVE-2022-28328)

A vulnerability has been identified in SCALANCE W1788-1 M12 All versions V3.0.0, SCALANCE W1788-2 EEC M12 All versions V3.0.0, SCALANCE W1788-2 M12 All versions V3.0.0, SCALANCE W1788-2IA M12 All versions V3.0.0. Affected devices do not properly handle malformed Multicast LLC frames. This could...

7.8CVSS7.2AI score0.00932EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.62 views

Siemens SCALANCE LPE940 and Ruggedcom ROX Devices Improper Preservation of Permissions (CVE-2022-0847)

A flaw was found in the way the flags member of the new pipe buffer structure was lacking proper initialization in copypagetoiterpipe and pushpipe functions in the Linux kernel and could thus contain stale values. An unprivileged local user could use this flaw to write to pages in the page cache...

7.8CVSS6.9AI score0.88606EPSS
SaveExploits101References10
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.30 views

Siemens SCALANCE M-800 & S615 Sensitive Cookie in HTTPS Session Without 'Secure' Attribute (CVE-2016-7090)

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session. This...

4.3CVSS5.1AI score0.01895EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.30 views

Siemens SCALANCE W1750D Improper Input Validation (CVE-2021-25155)

A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below...

8.5CVSS6.9AI score0.1242EPSS
SaveExploits6References6
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.38 views

Siemens SCALANCE W1750D Classic Buffer Overflow (CVE-2022-37886)

There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI Aruba Networks AP management protocol UDP port 8211. Successful exploitation of these vulnerabilities result...

9.8CVSS7.9AI score0.01495EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.26 views

Siemens SCALANCE W1750D Use of Externally-Controlled Format String (CVE-2021-37735)

A remote denial of service vulnerability was discovered in Aruba Instant versions: Aruba Instant 6.5.x.x: 6.5.4.18 and below; Aruba Instant 8.5.x.x: 8.5.0.10 and below; Aruba Instant 8.6.x.x: 8.6.0.4 and below. Aruba has released patches for Aruba Instant IAP that address this security...

5.3CVSS5.8AI score0.0129EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.23 views

Siemens SCALANCE Missing Encryption of Sensitive Data (CVE-2021-37731)

A local path traversal vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software versions: Prior to 8.6.0.0-2.2.0.4; Prior to 8.7.1.1, 8.6.0.7, 8.5.0.12, 8.3.0.16. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address...

7.2CVSS6.8AI score0.00325EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.30 views

Siemens SCALANCE W1750D Improper Neutralization of Input During Web Page Generation (CVE-2022-37892)

A vulnerability in the Aruba InstantOS and ArubaOS 10 web management interface could allow an unauthenticated remote attacker to conduct a stored cross-site scripting XSS attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a...

5.4CVSS6.6AI score0.00617EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.26 views

Siemens Ruggedcom ROS, SCALANCE Improper Access Control (CVE-2017-12736)

A vulnerability has been identified in RUGGEDCOM ROS for RSL910 devices All versions ROS V5.0.1, RUGGEDCOM ROS for all other devices All versions ROS V4.3.4, SCALANCE XB-200/XC-200/XP-200/XR300-WG All versions between V3.0 including and V3.0.2 excluding, SCALANCE XR-500/XM-400 All versions betwee...

8.8CVSS7.6AI score0.00999EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.27 views

Siemens SCALANCE W1750D Command Injection (CVE-2021-25162)

A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and...

9.3CVSS7.6AI score0.25573EPSS
SaveExploits4References5
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.27 views

Siemens SCALANCE M875 Arbitrary OS Command Execution (CVE-2018-4859)

A vulnerability has been identified in SCALANCE M875 All versions. An authenticated remote attacker with access to the web interface 443/tcp, could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker...

9CVSS7.7AI score0.03737EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.25 views

Siemens SCALANCE Command Injection (CVE-2021-37723)

A remote arbitrary command execution vulnerability was discovered in Aruba Operating System Software versions: Prior to 8.7.1.2, 8.6.0.8, 8.5.0.12, 8.3.0.16. Aruba has released patches for ArubaOS that address this security vulnerability. This plugin only works with Tenable.ot. Please visit...

9CVSS7.2AI score0.03055EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.28 views

Siemens Scalance W-7xx Series Hard-coded SSL Certificate (CVE-2013-4651)

Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the- middle attacks against SSL sessions by leveraging the certificate's trust relationship. Th...

6.6CVSS5.5AI score0.00951EPSS
SaveExploits1References2
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.21 views

Siemens SCALANCE Products Improper Adherence to Coding Standards (CVE-2019-10927)

A vulnerability has been identified in SCALANCE SC-600 V2.0, SCALANCE XB-200 V4.1, SCALANCE XC-200 V4.1, SCALANCE XF-200BA V4.1, SCALANCE XP-200 V4.1, SCALANCE XR-300WG V4.1. An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service...

6.5CVSS6.3AI score0.01168EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.18 views

Siemens SCALANCE W1750D Classic Buffer Overflow (CVE-2021-25144)

A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Insta...

9CVSS7.6AI score0.02146EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.24 views

Siemens SCALANCE W1700 Improper Input Validation (CVE-2022-28329)

A vulnerability has been identified in SCALANCE W1788-1 M12 All versions V3.0.0, SCALANCE W1788-2 EEC M12 All versions V3.0.0, SCALANCE W1788-2 M12 All versions V3.0.0, SCALANCE W1788-2IA M12 All versions V3.0.0. Affected devices do not properly handle malformed TCP packets received over the...

6.5CVSS6.4AI score0.00363EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.35 views

Siemens SCALANCE and SIMATIC Uncontrolled Resource Consumption (CVE-2019-19301)

A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALAN...

7.5CVSS7.4AI score0.01327EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.21 views

Siemens SCALANCE S Improper Neutralization of Input During Web Page Generation (CVE-2018-16555)

A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...

5.4CVSS5.6AI score0.00689EPSS
SaveExploits0References4