Lucene search
+L

2411 matches found

Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•10 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42152)

nvmet: possible leak when destroy a ctrl during qp establishment. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504784; scriptversion"1.3";...

7.5CVSS6.1AI score0.00733EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•6 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41095)

drm/nouveau/dispnv04: null pointer dereference in nv17tvgetldmodes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504742; scriptversion"1.3";...

5.5CVSS6AI score0.00236EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•4 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56548)

hfsplus: Devices block sizes may change. One of these cases is a loop device by using ioctl LOOPSETBLOCKSIZE. While this may cause other issues like IO being rejected, in the case of hfsplus, it will allocate a block by using that size and potentially write out-of- bounds when hfsplusreadwrapper...

7.8CVSS6.8AI score0.00247EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•13 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40932)

drm/exynos/vidi: memory leak in .getmodes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504673; scriptversion"1.3";...

5.5CVSS5.8AI score0.00261EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•10 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42223)

media: dvb-frontends: tda10048: integer overflow state-xtalhz can be up to 16M, so it can overflow a 32 bit integer when multiplied by pllmfactor. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable,...

5.5CVSS6.4AI score0.00233EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•8 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46817)

drm/amd/display: Stop amdgpudm initialize when stream nums greater than 6. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504454;...

7.4CVSS6.6AI score0.00263EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•13 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46721)

apparmor: fix possible NULL pointer dereference. profile-parent-dentsAAFSPROFDIR could be NULL only if its parent is made from createmissingancestors.. and 'ent-old' is NULL in aareplaceprofiles... In that case, it must return an error code and the code, -ENOENT represents its state that the path...

5.5CVSS6.5AI score0.00233EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•12 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56747)

scsi: qedi: vulnerability involves a potential memory leak in qediallocandinitsb where the DMA memory sbvirt is not released upon failure, which is fixed by adding dmafreecoherent to free the memory, similar to other functions like qedrallocmemsb and qedeallocmemsb. This plugin only works with...

5.5CVSS6.5AI score0.0023EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•8 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42148)

bnx2x: multiple UBSAN array-index-out-of-bounds. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504470; scriptversion"1.2";...

7.8CVSS6.1AI score0.00259EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•19 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-47143)

dma-debug: possible deadlock on radixlock. radixlock shouldn't be held while holding dmahashentryidx.lock otherwise, there's a possible deadlock scenario when dma debug API is called holding rqlock. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot f...

5.5CVSS6.9AI score0.00188EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•11 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-44998)

atm: idt77252: use after free in dequeuerx. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504512; scriptversion"1.2";...

9.8CVSS7.4AI score0.00787EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•5 views

Siemens SCALANCE and RUGGEDCOM Devices Use After Free (CVE-2024-56581)

btrfs: ref-verify: use-after-free after invalid ref action. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504648; scriptversion"1.3";...

7.8CVSS7.5AI score0.00236EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•8 views

Siemens SCALANCE and RUGGEDCOM Devices Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition') (CVE-2024-42232)

libceph: fix race between delayedwork and cephmoncstop The way the delayed work is handled in cephmoncstop is prone to races with monfault and possibly also finishhunting. Both of these can requeue the delayed work which wouldn't be canceled by any of the following code in case that happens after...

9.8CVSS6.7AI score0.0076EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•6 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41022)

drm/amdgpu: vulnerability involves a signedness problem in sdmav40processtrapirq, which can lead to incorrect handling of values and potential errors. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...

7CVSS6.3AI score0.0024EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•8 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46761)

pci/hotplug/pnvphp: hotplug driver crash on Powernv. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504790; scriptversion"1.3";...

5.5CVSS6.8AI score0.00251EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•11 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-44988)

net: dsa: mv88e6xxx: vulnerability caused an out-of-bound access in the mv88e6xxx driver due to an ATU violation causing the SPID to exceed DSAMAXPORTS, which was resolved by ensuring the SPID stays within the valid range. This plugin only works with Tenable.ot. Please visit...

8.8CVSS6.8AI score0.00355EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•8 views

Siemens SCALANCE and RUGGEDCOM Devices Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition') (CVE-2024-40943)

ocfs2: fix races between hole punching and AIO+DIO. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504517; scriptversion"1.2";...

7.8CVSS6.1AI score0.00197EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•20 views

Siemens SCALANCE and RUGGEDCOM Devices Missing Release of Memory after Effective Lifetime (CVE-2024-56572)

media: platform: allegro-dvt: possible memory leak in allocatebuffersinternal. If The buffer in the loop is not released under the exception path, it may lead to a memory leak. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...

5.5CVSS6.8AI score0.00236EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•10 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-37078)

nilfs2: kernel vulnerability due to lack of writeback flag waiting. When the log writer starts a writeback for segment summary blocks or a super root block that use the backing devices page cache, it does not wait for the ongoing folio/page writeback, resulting in an inconsistent writeback state...

7.8CVSS6.2AI score0.00259EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•17 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41064)

powerpc/eeh: possible crash when edev-pdev changes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504739; scriptversion"1.3";...

7.8CVSS6.9AI score0.00239EPSS
SaveExploits0References4