Lucene search
+L

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56723)

🗓️ 18 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 17 Views

Siemens SCALANCE and RUGGEDCOM devices have improper input validation in PMIC IRQ handling (CVE-2024-56723).

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504481);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2025/11/18");

  script_cve_id("CVE-2024-56723");

  script_name(english:"Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56723)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"mfd: intel_soc_pmic_bxtwc: Use IRQ domain for PMIC devices. While
design wise the idea of converting the driver to use the hierarchy of
the IRQ chips is correct, the implementation has (inherited)
vulnerabilities. This was unveiled when platform_get_irq() had started
WARN() on IRQ 0 that is supposed to be a Linux IRQ number (also known
as vIRQ).

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-355557.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-56723");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(20);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh-300_series_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
        {"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
    "cpe:/o:siemens:scalance_xc-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xr-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xc-400_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX400"},
    "cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xr-500_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xcm-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xrm-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xch-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xrh-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

18 Nov 2025 00:00Current
6.8Medium risk
Vulners AI Score6.8
CVSS 3.15.5
EPSS0.00233
SSVC
17