Lucene search
+L

4134 matches found

Cvelist
Cvelist
•added 2013/09/09 10:00 a.m.•37 views

CVE-2013-2791

MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service master-station daemon crash via a malformed DNP3 TCP packet from the IP address of an outstation...

6.6AI score0.0126EPSS
SaveExploits0References2
CVE
CVE
•added 2013/09/09 10:00 a.m.•87 views

CVE-2013-2793

CVE-2013-2793 affects Triangle MicroWorks SCADA Data Gateway (v2.50.0309–v3.00.0616), DNP3 .NET Protocol components (v3.06.0.171–v3.15.0.369), and DNP3 ANSI C libraries (v3.06.0000–v3.15.0000). The vulnerability is improper input validation that allows an attacker to cause a denial of service (in...

7.8CVSS6.8AI score0.0147EPSS
SaveExploits0References2Affected Software3
Cvelist
Cvelist
•added 2013/09/09 10:00 a.m.•44 views

CVE-2013-2794

Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service infinite loop via crafted input over a serial line...

6.5AI score0.00317EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/09/09 12:00 a.m.•11 views

CVE-2013-2791: Improper Restriction of Operations within the Bounds of a Memory Buffer

MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service master-station daemon crash via a malformed DNP3 TCP packet from the IP address of an outstation...

7.1CVSS5.8AI score0.0126EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/09/09 12:00 a.m.•10 views

CVE-2013-2793: Improper Restriction of Operations within the Bounds of a Memory Buffer

Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service infinite loop via a crafted DNP3 TCP packet...

7.8CVSS5.8AI score0.0147EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/09/09 12:00 a.m.•13 views

CVE-2013-2794: Improper Restriction of Operations within the Bounds of a Memory Buffer

Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service infinite loop via crafted input over a serial line...

4.9CVSS5.7AI score0.00317EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2013/09/09 12:00 a.m.•7 views

PT-2013-3934

Name of the Vulnerable Software and Affected Versions MatrikonOPC SCADA DNP3 OPC Server version 1.2.0 Description The issue allows remote attackers to cause a denial of service, resulting in a master-station daemon crash. This can be achieved by sending a malformed DNP3 TCP packet from the IP...

7.1CVSS0.0126EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2013/09/09 12:00 a.m.•10 views

PT-2013-3937

Name of the Vulnerable Software and Affected Versions Triangle MicroWorks SCADA Data Gateway versions 2.50.0309 through 3.00.0616 DNP3 .NET Protocol components versions 3.06.0.171 through 3.15.0.369 DNP3 C libraries versions 3.06.0000 through 3.15.0000 Description The issue allows physically...

4.9CVSS0.00317EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2013/09/09 12:00 a.m.•10 views

PT-2013-3936

Name of the Vulnerable Software and Affected Versions Triangle MicroWorks SCADA Data Gateway versions 2.50.0309 through 3.00.0616 DNP3 .NET Protocol components versions 3.06.0.171 through 3.15.0.369 DNP3 C libraries versions 3.06.0000 through 3.15.0000 Description The issue allows remote attacker...

7.8CVSS0.0147EPSS
SaveExploits0References3
ICS
ICS
•added 2013/08/12 12:00 p.m.•66 views

Siemens WinCC Exploitable Crashes

Overview ICS-CERT Advisory ICSA-11-175-02P was originally released to the US-CERT Portal on June 24, 2011. This web page release was delayed to allow users sufficient time to download and install the update. ICS-CERT has received a report from independent security researchers Billy Rios and Terry...

7.9AI score
SaveExploits0References18
Prion
Prion
•added 2013/08/09 11:55 p.m.•24 views

Xxe

Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service CPU and memory consumption via an XML document containing an...

6.9CVSS7.4AI score0.00726EPSS
SaveExploits0References2Affected Software3
CVE
CVE
•added 2013/08/09 11:00 p.m.•94 views

CVE-2013-2796

This entry (CVE-2013-2796) describes an XML External Entity (XXE) vulnerability in Schneider Electric products: Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier. The underlying issue is improper restriction of XML entities, allowing a remote attac...

6.9CVSS7.1AI score0.00726EPSS
SaveExploits0References2Affected Software3
Cvelist
Cvelist
•added 2013/08/09 11:00 p.m.•42 views

CVE-2013-2796

Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service CPU and memory consumption via an XML document containing an...

6.9AI score0.00726EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/08/09 12:00 a.m.•11 views

CVE-2013-2796: Undefined Security Weakness

Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service CPU and memory consumption via an XML document containing an...

6.9CVSS6AI score0.00726EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2013/08/09 12:00 a.m.•9 views

PT-2013-1316

Name of the Vulnerable Software and Affected Versions Schneider Electric Vijeo Citect versions 7.20 and earlier Schneider Electric CitectSCADA versions 7.20 and earlier Schneider Electric PowerLogic SCADA versions 7.20 and earlier Description The issue allows remote attackers to read arbitrary...

6.9CVSS0.00726EPSS
SaveExploits0References6
The Hacker News
The Hacker News
•added 2013/08/05 4:18 p.m.•13 views

Chinese Hackers Caught by US water control system Honeypots

A notorious Chinese hacker collective known as APT1 or Comment Crew, possibly linked to the Chinese Army, have been caught red handed breaking into a fake United States water control system i.e. known as a Honeypot. Kyle Wilhoit, a researcher with security company Trend Micro has just revealed th...

7.3AI score
SaveExploits0
The Hacker News
The Hacker News
•added 2013/08/05 5:18 a.m.•66 views

Chinese Hackers Caught by US water control system Honeypots

A notorious Chinese hacker collective known as APT1 or Comment Crew, possibly linked to the Chinese Army, have been caught red handed breaking into a fake United States water control system i.e. known as a Honeypot. Kyle Wilhoit, a researcher with security company Trend Micro has just revealed th...

7.3AI score
SaveExploits0
NVD
NVD
•added 2013/07/31 1:20 p.m.•54 views

CVE-2013-2785

Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted...

9.3CVSS7.8AI score0.03769EPSS
SaveExploits0References2
Prion
Prion
•added 2013/07/31 1:20 p.m.•24 views

Buffer overflow

Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted...

9.3CVSS8.4AI score0.03769EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2013/07/31 10:00 a.m.•80 views

CVE-2013-2785

CVE-2013-2785 affects GE Intelligent Platforms Proficy HMI/SCADA CIMPLICITY (WebView/CimWebServer). The vulnerability stems from improper input handling in CimWebServer’s WebView, allowing a remote attacker to execute arbitrary code by sending crafted data to TCP port 10212. Affected installation...

9.3CVSS8AI score0.03769EPSS
SaveExploits0References2Affected Software2
Rows per page
Query Builder