4133 matches found
CVE-2014-0752
The CVE-2014-0752 case concerns Ecava IntegraXor SCADA server prior to 4.1.4369, where the project directory contains files that can be downloaded via a crafted URL due to improper access control. This leads to disclosure of project backup files (partial confidentiality impact) and is exploitable...
CVE-2014-0752 Ecava IntegraXor Exposure of Access Control List Files to an Unauthorized Control Sphere
The SCADA server in Ecava IntegraXor before 4.1.4369 allows remote attackers to read arbitrary project backup files via a crafted URL...
Siemens Fixes Authentication Bugs in Scalance X-200 Switches
Researchers have discovered two serious vulnerabilities in industrial Ethernet switches manufactured by Siemens that could enable attackers to perform unauthorized actions on the switches without authentication. One of the bugs allows attackers to hijack Web sessions and the other enables them to...
CVE-2014-0752: Exposure of Access Control List Files to an Unauthorized Control Sphere
The SCADA server in Ecava IntegraXor before 4.1.4369 allows remote attackers to read arbitrary project backup files via a crafted URL...
Triangle MicroWorks DNP3畸形数据Set/Device属性处理非法数据访问漏洞
Triangle MicroWorks是一家总部设在美国的公司,Triangle MicroWorks产品是单机或第三方组件产品,使用各种传输协议与外设/从设备进行通信OPC Client, IEC 60870-6 TASE.2/ICCP Client, IEC 60870-5, DNP3, Modbus。 Triangle Research DNP3从源代码库Slave Source Code Library处理进行数据set和device属性时存在缺陷,可导致访问非法数据访问而使链接该库的应用程序崩溃。 0 Triangle MicroWorks DNP3 Slave Source...
Growing market of zero-day vulnerability exploits pose real threat to Cyber Security
NSS Labs issued the report titled "The Known Unknowns" to explain the dynamics behind the market of zero-day exploits. Last week I discussed about the necessity to define a model for "cyber conflict" to qualify the principal issues related to the use of cyber tools and cyber weapons in an...
CVE-2013-2823: Improper Input Validation
The 1 Catapult DNP3 I/O driver before 7.2.0.60 and the 2 GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe aka the DNP master station server in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a deni...
CVE-2013-2811: Improper Input Validation
The 1 Catapult DNP3 I/O driver before 7.2.0.60 and the 2 GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe aka the DNP master station server in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service...
ARC PcVue ActiveX Control SCADA Remote Code Execution (CVE-2011-4042; CVE-2011-4043 ; CVE-2011-4044; CVE-2011-4045)
A buffer overflow vulnerability has been reported in SCADA ARC PcVue...
Ecava IntegraXor ActiveX Buffer Overflow
Overview This advisory provides mitigation details for a vulnerability that impacts the Ecava IntegraXor application. Independent researcher Andrew Brooks has identified a buffer overflow vulnerability in Ecava’s IntegraXor application. Ecava has produced a patch that mitigates this vulnerability...
GE Intelligent Platforms Proficy SCADA Substitute.bcl Directory Traversal (CVE-2013-0653)
A directory traversal vulnerability has been reported in GE Intelligent Platforms Proficy...
Siemens Simatic SCADA WINCC SQL Insecure Default Credentials Security Bypass (CVE-2010-2772)
A security bypass vulnerability has been reported in Siemens SIMATIC WinCC server. A remote attacker can exploit this issue by using the default hard-coded password to bypass certain security restrictions and gain access to the application's database...
InduSoft ISSymbol ActiveX Control Buffer Overflow (Update A)
Overview Security researcher Dmitriy Pletnevo of Secunia ResearchSecunia Research, http://secunia.com/secuniaresearch/2011-36/, website last accessed June 16, 2011. has released details of multiple overflow vulnerabilities affecting the InduSoft ISSymbol ActiveX control. The researcher identified...
GE Intelligent Platforms Proficy Cimplicity Multiple Vulnerabilities
Overview This advisory provides mitigation details for multiple vulnerabilities that impact GE Intelligent Platforms Proficy HMI/SCADA—CIMPLICITY. General Electric GE has addressed two vulnerabilities in GE Intelligent Platforms Proficy HMI/SCADA—CIMPLICITY: a directory transversal vulnerability...
Moore Industries Embedded SCADA server detection
Binary data 8034.prm...
Hirschmann Automation and Control Embedded SCADA server detection
Binary data 8030.prm...
Cogent DataHub Tunnel/Mirror Service Detection
Binary data scadacogentdatahubdetection.nbin...
Interactive Graphical SCADA System Remote Command Injection
This module requires Metasploit: http//metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework require 'msf/core' class Metasploit3 'Interactive Graphical SCADA System Remote Command Injection', 'Description' = %q This module abuses a directory traversal flaw in...
Interactive Graphical SCADA System Remote Command Injection
This Metasploit module abuses a directory traversal flaw in Interactive Graphical SCADA System v9.00. In conjunction with the traversal flaw, if opcode 0x17 is sent to the dc.exe process, an attacker may be able to execute arbitrary system commands. This module requires Metasploit:...
Interactive Graphical SCADA System - Remote Command Injection (Metasploit)
This module requires Metasploit: http//metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework require 'msf/core' class Metasploit3 'Interactive Graphical SCADA System Remote Command Injection', 'Description' = %q This module abuses a directory traversal flaw in...