4119 matches found
CVE-2020-6970
A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 if Modbus or ROC Interfaces have been installed and are in use and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server...
Heap overflow
A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 if Modbus or ROC Interfaces have been installed and are in use and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server...
CVE-2020-6970
The CVE-2020-6970 issue affects Emerson OpenEnterprise SCADA Server: OpenEnterprise Server 2.83 (with Modbus or ROC Interfaces in use) and OpenEnterprise 3.1–3.3.3. It is a heap-based buffer overflow enabling a specially crafted script to execute code on the OpenEnterprise Server. Mitigation per ...
CVE-2020-6970: Heap-based Buffer Overflow
A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 if Modbus or ROC Interfaces have been installed and are in use and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server...
Emerson OpenEnterprise SCADA Server Buffer Overflow Vulnerability
Emerson Electric OpenEnterprise SCADA Server is a suite of data acquisition and monitoring system SCADA servers from Emerson Electric that are primarily used for remote oil and gas applications. A buffer overflow vulnerability exists in Emerson Electric OpenEnterprise versions 3.1 through 3.3.3 a...
Emerson OpenEnterprise
1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Emerson Equipment: OpenEnterprise SCADA Server Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code on an OpenEnterprise SCADA...
Advantech WebAccess SCADA Stack-based Buffer Overflow (CVE-2019-3975; CVE-2019-3951)
A stack-based buffer overflow vulnerability exists in the webvrpcs service of Advantech WebAccess. Successful exploitation of this vulnerability could allow a remote attacker to execute arbitrary code on the affected system...
ASSURE Aviation Cyber Security Testing
We've long been supporters and champions of a formalised approach to Aviation Cyber Security Testing. Our research and blogging has taken us on an interesting journey regarding airside and landside security, mapping attack surfaces and explaining how systems work and interact. Speaking and...
CVE-2019-13537
The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash...
Buffer overflow
The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash...
CVE-2019-13537
The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash...
CVE-2019-13537
The CVE-2019-13537 issue affects the IEC870IP driver used in AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation. The vulnerability is a stack-based buffer overflow in the IEC870IP driver (versions 4.14.02 and earlier) that could lead to a server-side crash. Red H...
CVE-2019-13537: Stack-based Buffer Overflow
The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash...
PT-2020-9405
Name of the Vulnerable Software and Affected Versions: AVEVA Vijeo Citect and Citect SCADA affected versions not specified Schneider Electric Power SCADA Operation affected versions not specified Description: The issue is related to a buffer overflow that could cause a server-side crash in the...
CVE-2019-6854
A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert ClearSCADA -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the...
CVE-2019-6854
A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert ClearSCADA -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the...
CVE-2019-6854
CVE-2019-6854 concerns an improper authentication vulnerability in EcoStruxure Geo SCADA Expert (ClearSCADA). The issue is located in a folder within the product and, if exploited by a low-privilege user who has OS filesystem access, could allow deletion or modification of database, settings, or ...
PT-2020-11215
Name of the Vulnerable Software and Affected Versions EcoStruxure Geo SCADA Expert ClearSCADA versions prior to 2019 Description A vulnerability exists in a folder within EcoStruxure Geo SCADA Expert ClearSCADA which could cause a low privilege user to delete or modify database, setting or...
CVE-2019-6854: Improper Authentication
A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert ClearSCADA -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the...
LAquis SCADA LGX Out-Of-Bounds Write (CVE-2018-18986)
An out-of-bounds write vulnerability exists in the LAquis SCADA. This vulnerability is due to improper validation of user-supplied data when parsing the LGX report file. Successful exploitation would result in a denial of service condition...