Lucene search
+L

4119 matches found

NVD
NVD
•added 2020/02/19 9:15 p.m.•33 views

CVE-2020-6970

A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 if Modbus or ROC Interfaces have been installed and are in use and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server...

9.8CVSS9.7AI score0.02579EPSS
SaveExploits0References1
Prion
Prion
•added 2020/02/19 9:15 p.m.•23 views

Heap overflow

A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 if Modbus or ROC Interfaces have been installed and are in use and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server...

7.5CVSS9.6AI score0.02579EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2020/02/19 8:19 p.m.•109 views

CVE-2020-6970

The CVE-2020-6970 issue affects Emerson OpenEnterprise SCADA Server: OpenEnterprise Server 2.83 (with Modbus or ROC Interfaces in use) and OpenEnterprise 3.1–3.3.3. It is a heap-based buffer overflow enabling a specially crafted script to execute code on the OpenEnterprise Server. Mitigation per ...

9.8CVSS9.5AI score0.02579EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/19 12:00 a.m.•6 views

CVE-2020-6970: Heap-based Buffer Overflow

A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 if Modbus or ROC Interfaces have been installed and are in use and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server...

9.8CVSS8.1AI score0.02579EPSS
SaveExploits0References3
CNVD
CNVD
•added 2020/02/19 12:00 a.m.•21 views

Emerson OpenEnterprise SCADA Server Buffer Overflow Vulnerability

Emerson Electric OpenEnterprise SCADA Server is a suite of data acquisition and monitoring system SCADA servers from Emerson Electric that are primarily used for remote oil and gas applications. A buffer overflow vulnerability exists in Emerson Electric OpenEnterprise versions 3.1 through 3.3.3 a...

9.8CVSS7.3AI score0.02579EPSS
SaveExploits0References1
ICS
ICS
•added 2020/02/18 12:00 a.m.•80 views

Emerson OpenEnterprise

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Emerson Equipment: OpenEnterprise SCADA Server Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code on an OpenEnterprise SCADA...

9.8CVSS9.7AI score0.02579EPSS
SaveExploits0References5
Check Point Advisories
Check Point Advisories
•added 2020/02/17 12:00 a.m.•58 views

Advantech WebAccess SCADA Stack-based Buffer Overflow (CVE-2019-3975; CVE-2019-3951)

A stack-based buffer overflow vulnerability exists in the webvrpcs service of Advantech WebAccess. Successful exploitation of this vulnerability could allow a remote attacker to execute arbitrary code on the affected system...

7.5CVSS5.5AI score0.04568EPSS
SaveExploits2
Pen Test Partners Blog
Pen Test Partners Blog
•added 2020/01/30 7:11 a.m.•62 views

ASSURE Aviation Cyber Security Testing

We've long been supporters and champions of a formalised approach to Aviation Cyber Security Testing. Our research and blogging has taken us on an interesting journey regarding airside and landside security, mapping attack surfaces and explaining how systems work and interact. Speaking and...

6.8AI score
SaveExploits0
NVD
NVD
•added 2020/01/14 7:15 p.m.•46 views

CVE-2019-13537

The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash...

7.5CVSS7.8AI score0.01297EPSS
SaveExploits0References2
Prion
Prion
•added 2020/01/14 7:15 p.m.•28 views

Buffer overflow

The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash...

5CVSS7.7AI score0.01297EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2020/01/14 6:05 p.m.•45 views

CVE-2019-13537

The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash...

7.8AI score0.01297EPSS
SaveExploits0References2
CVE
CVE
•added 2020/01/14 6:05 p.m.•69 views

CVE-2019-13537

The CVE-2019-13537 issue affects the IEC870IP driver used in AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation. The vulnerability is a stack-based buffer overflow in the IEC870IP driver (versions 4.14.02 and earlier) that could lead to a server-side crash. Red H...

7.5CVSS7.8AI score0.01297EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/01/14 12:00 a.m.•6 views

CVE-2019-13537: Stack-based Buffer Overflow

The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash...

7.5CVSS7.5AI score0.01297EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2020/01/14 12:00 a.m.•5 views

PT-2020-9405

Name of the Vulnerable Software and Affected Versions: AVEVA Vijeo Citect and Citect SCADA affected versions not specified Schneider Electric Power SCADA Operation affected versions not specified Description: The issue is related to a buffer overflow that could cause a server-side crash in the...

7.5CVSS0.01297EPSS
SaveExploits0References4
NVD
NVD
•added 2020/01/06 11:15 p.m.•34 views

CVE-2019-6854

A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert ClearSCADA -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the...

7.8CVSS7.6AI score0.00167EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2020/01/06 10:56 p.m.•40 views

CVE-2019-6854

A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert ClearSCADA -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the...

7.7AI score0.00167EPSS
SaveExploits0References1
CVE
CVE
•added 2020/01/06 10:56 p.m.•172 views

CVE-2019-6854

CVE-2019-6854 concerns an improper authentication vulnerability in EcoStruxure Geo SCADA Expert (ClearSCADA). The issue is located in a folder within the product and, if exploited by a low-privilege user who has OS filesystem access, could allow deletion or modification of database, settings, or ...

7.8CVSS7.6AI score0.00167EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2020/01/06 12:00 a.m.•6 views

PT-2020-11215

Name of the Vulnerable Software and Affected Versions EcoStruxure Geo SCADA Expert ClearSCADA versions prior to 2019 Description A vulnerability exists in a folder within EcoStruxure Geo SCADA Expert ClearSCADA which could cause a low privilege user to delete or modify database, setting or...

7.8CVSS0.00167EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/01/06 12:00 a.m.•6 views

CVE-2019-6854: Improper Authentication

A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert ClearSCADA -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the...

7.8CVSS7.2AI score0.00167EPSS
SaveExploits0References2
Check Point Advisories
Check Point Advisories
•added 2020/01/01 12:00 a.m.•40 views

LAquis SCADA LGX Out-Of-Bounds Write (CVE-2018-18986)

An out-of-bounds write vulnerability exists in the LAquis SCADA. This vulnerability is due to improper validation of user-supplied data when parsing the LGX report file. Successful exploitation would result in a denial of service condition...

8.3CVSS3.6AI score0.02668EPSS
SaveExploits0
Rows per page
Query Builder