4119 matches found
CVE-2020-10615
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
CVE-2020-10615
CVE-2020-10615 affects Triangle MicroWorks SCADA Data Gateway, specifically versions 3.02.0697–4.0.122 and 2.41.0213–4.0.122. The root cause is improper validation of the length of user-supplied data prior to copying into a fixed-length stack-based buffer, causing a stack-based buffer overflow. T...
CVE-2020-6992
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...
Privilege escalation
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...
CVE-2020-6992
GE Digital CIMPLICITY HMI/SCADA vulnerability CVE-2020-6992 affects CIMPLICITY v10.0 and earlier. It is a local privilege escalation (CWE-269) that requires an authenticated session to modify the system and arbitrarily execute code. Affected component: CIMPLICITY HMI/SCADA software; root cause is...
CVE-2020-6992
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...
PT-2020-12241
Name of the Vulnerable Software and Affected Versions Triangle MicroWorks SCADA Data Gateway versions 2.41.0213 through 4.0.122 Triangle MicroWorks SCADA Data Gateway versions 3.02.0697 through 4.0.122 Description The issue allows remote attackers to disclose sensitive information due to the lack...
PT-2020-12243
Name of the Vulnerable Software and Affected Versions Triangle MicroWorks SCADA Data Gateway versions 2.41.0213 through 4.0.122 Triangle MicroWorks SCADA Data Gateway versions 3.02.0697 through 4.0.122 Description The issue allows remote attackers to cause a denial-of-service condition due to a...
CVE-2020-10615: Stack-based Buffer Overflow
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
CVE-2020-10611: Access of Resource Using Incompatible Type
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...
PT-2020-12239
Name of the Vulnerable Software and Affected Versions Triangle MicroWorks SCADA Data Gateway versions 2.41.0213 through 4.0.122 Triangle MicroWorks SCADA Data Gateway versions 3.02.0697 through 4.0.122 Description The issue allows remote attackers to execute arbitrary code due to the lack of prop...
CVE-2020-10613: Out-of-bounds Read
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...
Triangle MicroWorks SCADA Data Gateway Buffer Overflow Vulnerability
Triangle MicroWorks SCADA Data Gateway is a SCADA data gateway product from Triangle MicroWorks, Inc. A security vulnerability exists in Triangle MicroWorks SCADA Data Gateway versions 3.02.0697 through 4.0.122 and 2.41.0213 through 4.0.122, which arises from the program failing to properly...
CVE-2020-6992: Improper Privilege Management
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...
Triangle MicroWorks SCADA Data Gateway
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low skill level to exploit Vendor : Triangle MicroWorks Equipment : SCADA Data Gateway Vulnerabilities : Stacked-based Buffer Overflow, Out-of-Bounds Read, Type Confusion 2. RISK EVALUATION These vulnerabilities allow remote...
PT-2020-5890
Name of the Vulnerable Software and Affected Versions: GE Digital CIMPLICITY HMI/SCADA versions prior to 11.0 Description: A local privilege escalation issue has been identified, which could allow an adversary to modify the system, leading to the arbitrary execution of code if an attacker has...
The vulnerability of the zenone32.exe editor in the COPA-DATA SCADA system allows a intruder to execute arbitrary code.
The vulnerability of the zenone32.exe editor in the COPA-DATA SCADA system is related to an uncontrolled element in the search process. Exploiting this vulnerability could allow a perpetrator to execute arbitrary code...
Advantech WebAccess Buffer Overflow Vulnerability (CNVD-2020-19926)
Advantech WebAccess is a set of HMI/SCADA software based on browser architecture from Advantech, Taiwan, China. The software supports dynamic graphic display and real-time data control, and provides remote control and management of automation equipment. A buffer overflow vulnerability exists in...
Katana - A Python Tool For Google Hacking
Katana-ds ds for dorkscanner is a simple python tool that automates Google Hacking/Dorking and support Tor It becomes more powerful in combination with GHDB Installation : Use the package manager pip to install requirements cd Katana python3 pip install -r requirments python3 katana-ds.py Tested...
Advantech WebAccess SCADA Policy Bypass (CVE-2019-13552)
A policy bypass vulnerability exists in Advantech WebAccess. Successful exploitation of this vulnerability could allow the disclosure of sensitive information...