Lucene search
+L

4118 matches found

CNNVD
CNNVD
•added 2021/03/11 12:00 a.m.•21 views

Schneider Electric Interactive Graphical SCADA System 缓冲区错误漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. A buffer overflow vulnerability exists in Interactive Graphical SCADA System IGSS Definition...

9.3CVSS6.2AI score0.00883EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/03/11 12:00 a.m.•6 views

CVE-2021-22710: Improper Restriction of Operations within the Bounds of a Memory Buffer

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System IGSS Definition Def.exe V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF Configuration Group File file is imported to IGS...

9.3CVSS6.3AI score0.02219EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/03/11 12:00 a.m.•5 views

CVE-2021-22712: Improper Restriction of Operations within the Bounds of a Memory Buffer

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System IGSS Definition Def.exe V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF Configuration Group File file i...

9.3CVSS5.8AI score0.00933EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/03/11 12:00 a.m.•7 views

CVE-2021-22709: Improper Restriction of Operations within the Bounds of a Memory Buffer

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System IGSS Definition Def.exe V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF Configuration Group File fil...

9.3CVSS6.2AI score0.02219EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2021/03/11 12:00 a.m.•18 views

Schneider Electric Interactive Graphical SCADA System 缓冲区错误漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. A buffer overflow vulnerability exists in Interactive Graphical SCADA System IGSS Definition...

9.3CVSS6.2AI score0.00933EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/03/11 12:00 a.m.•6 views

CVE-2021-22711: Improper Restriction of Operations within the Bounds of a Memory Buffer

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System IGSS Definition Def.exe V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF Configuration Group File file i...

9.3CVSS5.9AI score0.00883EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2021/03/11 12:00 a.m.•22 views

Schneider Electric Interactive Graphical SCADA System 缓冲区错误漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. A buffer overflow vulnerability exists in Interactive Graphical SCADA System IGSS Definition...

9.3CVSS6.5AI score0.02219EPSS
SaveExploits0References6
ICS
ICS
•added 2021/03/11 12:00 a.m.•91 views

Schneider Electric IGSS SCADA Software

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Schneider Electric Equipment: IGSS Interactive Graphical SCADA System Vulnerabilities: Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of these...

9.3CVSS8.4AI score0.02219EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2021/03/09 12:00 a.m.•4 views

PT-2021-2377

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System IGSS versions prior to 15.0.0.21041 Description The issue is caused by a buffer overflow in memory, allowing a remote attacker to read or write arbitrary files using a specially crafted CGF file. This is due ...

9.3CVSS0.00883EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2021/03/09 12:00 a.m.•2 views

PT-2021-2378

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System IGSS versions 15.0.0.21041 and prior Description A memory buffer vulnerability exists, which could cause remote code execution when a malicious CGF Configuration Group File file is imported to IGSS Definition...

9.3CVSS0.02219EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
•added 2021/03/09 12:00 a.m.•3 views

PT-2021-2330

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System IGSS versions 15.0.0.21041 and prior Description A memory buffer vulnerability exists due to improper restriction of operations within the bounds of a memory buffer, which could result in arbitrary read or...

9.3CVSS0.00933EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2021/03/09 12:00 a.m.•2 views

PT-2021-2368

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System IGSS versions 15.0.0.21041 and prior Description A memory buffer vulnerability exists in the Interactive Graphical SCADA System IGSS Definition, which could result in loss of data or remote code execution whe...

9.3CVSS0.02219EPSS
SaveExploits0References7
OSV
OSV
•added 2021/03/03 5:15 p.m.•20 views

CVE-2020-13554

An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with ...

7.8CVSS7.3AI score0.00547EPSS
SaveExploits1References1
NVD
NVD
•added 2021/03/03 5:15 p.m.•42 views

CVE-2020-13554

An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with ...

8.8CVSS0.00547EPSS
SaveExploits1References1
Prion
Prion
•added 2021/03/03 5:15 p.m.•29 views

Privilege escalation

An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with ...

7.2CVSS8AI score0.00547EPSS
SaveExploits1References1Affected Software1
CVE
CVE
•added 2021/03/03 4:14 p.m.•69 views

CVE-2020-13554

Advantech WebAccess/SCADA 9.0.1 contains multiple local privilege escalation flaws stemming from weak permissions and executable/file tampering in the installation directory. The TALOS-2020-1169 analysis describes various vectors, including webvrpcs Run Key registry entry and multiple binaries/ex...

8.8CVSS8AI score0.00547EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
•added 2021/03/03 4:14 p.m.•54 views

CVE-2020-13554

An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with ...

8.8CVSS8.1AI score0.00547EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/03/03 12:00 a.m.•9 views

CVE-2020-13554: Incorrect Default Permissions

An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with ...

8.8CVSS6.1AI score0.00547EPSS
SaveExploits1References3
OSV
OSV
•added 2021/02/23 5:15 p.m.•22 views

CVE-2020-25161

The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator...

8.8CVSS7.4AI score0.01563EPSS
SaveExploits0References1
NVD
NVD
•added 2021/02/23 5:15 p.m.•30 views

CVE-2020-25161

The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator...

8.8CVSS0.01563EPSS
SaveExploits0References1
Rows per page
Query Builder