Advantech WebAccess/SCADA installation local file inclusion
Summary A local file inclusion vulnerability exists in the installation functionality of Advantech WebAccess/SCADA 9.0.1. A specially crafted application can lead to information disclosure. An attacker can send an authenticated HTTP request to trigger this vulnerability. Tested Versions Advantech...
Advantech WebAccess/SCADA 安全漏洞
Advantech WebAccess/SCADA is a suite of SCADA software from Advantech based on a browser architecture. The software supports dynamic graphical displays and real-time data control, and provides the ability to remotely control and manage automation equipment. A local elevation of privilege...
多款Advantech产品安全漏洞
Advantech WebAccess/SCADA is a suite of SCADA software from Advantech based on a browser architecture. The software supports dynamic graphical displays and real-time data control, and provides the ability to remotely control and manage automation equipment. A local elevation of privilege...
Advantech WebAccess/SCADA 路径遍历漏洞
Advantech WebAccess/SCADA is a suite of SCADA software from Advantech based on a browser architecture. The software supports dynamic graphical displays and real-time data control, and provides the ability to remotely control and manage automation equipment. A local file inclusion vulnerability...
Advantech WebAccess/SCADA 安全漏洞
Advantech WebAccess/SCADA is a suite of SCADA software from Advantech based on a browser architecture. The software supports dynamic graphical displays and real-time data control, and provides the ability to remotely control and manage automation equipment. A local elevation of privilege...
PT-2021-2348 · Advantech · Advantech Webaccess/Scada
Name of the Vulnerable Software and Affected Versions: Advantech WebAccess/SCADA version 9.0.1 Description: A local privilege elevation issue exists in the file system permissions of the installation, specifically in the webvrpcs Run Key Privilege Escalation. This allows an attacker to replace...
Racoms MIDGE Firmware 跨站请求伪造漏洞
The RACOM M!DGE is a cellular router designed for SCADA and telemetry mission-critical applications and is ideally suited for many different wireless applications. A cross-site request forgery vulnerability exists in the RACOM M!DGE firmware version 4.4.40.105. No detailed vulnerability details a...
Florida Water Plant Hack: Leaked Credentials Found in Breach Database
Researchers say they found several stolen and leaked credentials for a Florida water-treatment plant, which was hacked last week. Researchers at CyberNews said they found 11 credential pairs linked to the Oldsmar water plant, in a 2017 compilation of stolen breach credentials. Meanwhile, they als...
Compromise of U.S. Water Treatment Facility
Summary On February 5, 2021, unidentified cyber actors obtained unauthorized access to the supervisory control and data acquisition SCADA system at a U.S. drinking water treatment facility. The unidentified actors used the SCADA system’s software to increase the amount of sodium hydroxide, also...
Poor Password Security Led to Recent Water Treatment Facility Hack
New details have emerged about the remote computer intrusion at a Florida water treatment facility last Friday, highlighting a lack of adequate security measures needed to bulletproof critical infrastructure environments. The breach involved an unsuccessful attempt on the part of an adversary to...
Poor Password Security Led to Recent Water Treatment Facility Hack
New details have emerged about the remote computer intrusion at a Florida water treatment facility last Friday, highlighting a lack of adequate security measures needed to bulletproof critical infrastructure environments. The breach involved an unsuccessful attempt on the part of an adversary to...
Compromise of U.S. Water Treatment Facility
In response to recent events where unidentified cyber actors obtained unauthorized access to the supervisory control and data acquisition SCADA system at a U.S. drinking water treatment facility, CISA, the Federal Bureau of Investigation, the Environmental Protection Agency, and the Multi-State...
GE Digital HMI/SCADA iFIX Permission License and Access Control Issues Vulnerability
Genesys PureEngage Digital is an omni-channel customer interaction management platform from Genesys. The platform supports features such as online chat, email and SMS Short Message Service. A security vulnerability exists in GE Digital HMI/SCADA iFIX that originates from allowing a locally...
GE Digital HMI/SCADA iFIX
1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION: Low skill level to exploit Vendor: GE Digital Equipment: HMI/SCADA iFIX Vulnerabilities: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to escalate their...
Information leakage vulnerability in Cloud SCADA, cloud configuration software of Xiamen Haiwei Technology Co.
Xiamen Haiwei Technology Co., Ltd. is a high-tech enterprise integrating independent research and development, production, sales and service. Ltd. Cloud SCADA, a cloud configuration software, has an information leakage vulnerability that can be exploited by attackers to obtain sensitive informati...
Win-911 mobile server platform privilege escalation vulnerability
Summary An exploitable local privilege elevation vulnerability exists in the file system permissions of the Mobile-911 Server V2.5 install directory. Depending on the vector chosen, an attacker can overwrite the service executable and execute arbitrary code with System privileges or replace other...
SQL Injection Vulnerability in Tianxin SCADA System of Tianxin Instrumentation Group Co.
TIANXIN Instrumentation Group Limited is a professional service provider of flow meters and gas application system solutions in China. A SQL injection vulnerability exists in the TIANXIN SCADA system of TIANXIN Instrumentation Group Limited. An attacker can exploit the vulnerability to obtain...
Win-911 Enterprise Platform privilege escalation vulnerability
Summary Multiple exploitable local privilege elevation vulnerability exists in the file system permissions of the Win-911 Enterprise V4.20.13 install directory. Depending on the vector chosen, an attacker can overwrite various executables which could lead to escalation of the privileges when...
CVE-2020-28219
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1 and EcoStruxure Geo SCADA Expert 2020 Original release and Monthly Updates to September 2020, from 83.7551....
CVE-2020-28219
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1 and EcoStruxure Geo SCADA Expert 2020 Original release and Monthly Updates to September 2020, from 83.7551....