Lucene search
+L

4118 matches found

CVE
CVE
•added 2022/02/11 5:40 p.m.•96 views

CVE-2021-22803

Schneider Electric IGSS DC module (dc.exe, v15.0.0.21243 and prior) is affected by CVE-2021-22803: Unrestricted Upload of File with Dangerous Type, enabling remote code execution by writing arbitrary files to folders in the DC module context via network messages. Root cause: lack of validation du...

9.8CVSS9.6AI score0.01943EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2022/02/11 5:40 p.m.•98 views

CVE-2021-22802

Schneider Electric IGSS Data Collector (dc.exe), affected in IGSS v15.0.0.21243 and earlier, is vulnerable to a CWE-120 buffer overflow due to missing length checks on user-supplied data while processing a network-constructed message. This can lead to remote code execution with the dc.exe process...

9.8CVSS9.6AI score0.20165EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/11 12:00 a.m.•5 views

CVE-2021-22804: Improper Limitation of a Pathname to a Restricted Directory

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphica...

7.5CVSS7.3AI score0.01294EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2022/02/11 12:00 a.m.•5 views

PT-2022-9291

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Collector dc.exe version 15.0.0.21320 and prior Description A Missing Authentication for Critical Function issue exists due to lack of validation of network messages, which could cause deletion of...

9.1CVSS0.21388EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/11 12:00 a.m.•12 views

CVE-2021-22803: Unrestricted Upload of File with Dangerous Type

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product:...

9.8CVSS8.6AI score0.01943EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/11 12:00 a.m.•8 views

CVE-2021-22824: Buffer Copy without Checking Size of Input

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe...

7.5CVSS7.2AI score0.14241EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/11 12:00 a.m.•6 views

CVE-2021-22823: Missing Authentication for Critical Function

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...

9.1CVSS8.1AI score0.21388EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/11 12:00 a.m.•9 views

CVE-2021-22805: Missing Authentication for Critical Function

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21243...

9.1CVSS6.8AI score0.0085EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2022/02/11 12:00 a.m.•9 views

PT-2022-9292

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Collector dc.exe version 15.0.0.21320 and prior Description A buffer copy without checking the size of input issue exists, which could result in denial of service. This is due to a missing length check o...

7.5CVSS0.14241EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/11 12:00 a.m.•6 views

CVE-2021-22802: Buffer Copy without Checking Size of Input

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.ex...

9.8CVSS8.5AI score0.20165EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2022/02/11 12:00 a.m.•20 views

Schneider Electric Interactive Graphical SCADA System 缓冲区错误漏洞

The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. A buffer error vulnerability exists in the Schneider Electric Interactive Graphical SCADA...

7.5CVSS7.5AI score0.14241EPSS
SaveExploits0References3
attackerkb
attackerkb
•added 2022/02/09 11:15 p.m.•15 views

CVE-2022-24321

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...

7.5CVSS7.1AI score0.00999EPSS
SaveExploits0References2
attackerkb
attackerkb
•added 2022/02/09 11:15 p.m.•16 views

CVE-2022-24320

A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure G...

5.9CVSS6.3AI score0.00544EPSS
SaveExploits0References3
attackerkb
attackerkb
•added 2022/02/09 11:15 p.m.•12 views

CVE-2022-24319

A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...

5.9CVSS6.3AI score0.00575EPSS
SaveExploits0References3
attackerkb
attackerkb
•added 2022/02/09 11:15 p.m.•12 views

CVE-2022-24318

A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo SCADA Expert...

7.5CVSS7.1AI score0.00391EPSS
SaveExploits0References2
NVD
NVD
•added 2022/02/09 11:15 p.m.•38 views

CVE-2022-24318

A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo SCADA Expert...

7.5CVSS0.00391EPSS
SaveExploits0References1
NVD
NVD
•added 2022/02/09 11:15 p.m.•36 views

CVE-2022-24319

A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...

5.9CVSS0.00575EPSS
SaveExploits0References2
NVD
NVD
•added 2022/02/09 11:15 p.m.•42 views

CVE-2022-24320

A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure G...

5.9CVSS0.00544EPSS
SaveExploits0References2
NVD
NVD
•added 2022/02/09 11:15 p.m.•35 views

CVE-2022-24321

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...

7.5CVSS0.00999EPSS
SaveExploits0References1
OSV
OSV
•added 2022/02/09 11:15 p.m.•19 views

CVE-2022-24310

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Serv...

9.8CVSS6.5AI score0.02227EPSS
SaveExploits0References1
Rows per page
Query Builder