1910 matches found
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56739)
rtc: check if rtcreadtime was successful in rtctimerdowork If the rtcreadtime call fails, the struct rtctime tm; may contain uninitialized data, or an illegal date/time read from the RTC hardware. When calling rtctmtoktime later, the result may be a very large value possibly KTIMEMAX. If there ar...
Siemens SCALANCE and RUGGEDCOM Devices Use After Free (CVE-2024-50269)
usb: musb: sunxi: accessing an released usb phy will cause that usb phy @glue-xceiv is accessed after released. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41015)
ocfs2: add bounds checking to ocfs2checkdirentry. This adds sanity checks for ocfs2direntry to make sure all members of ocfs2direntry don't stray beyond valid memory region. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46740)
binder: UAF caused by offsets overwrite. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504456; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41081)
ila: block BH in ilaoutput. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504571; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41090)
tap: add missing verification for short frame. Missing to check against the validity of the frame length in the tapgetuserxdp path, which could cause a corrupted skb to be sent downstack. Even before the skb is transmitted, the tapgetuserxdp--skbsetnetworkheader may assume the size is more than...
Siemens SCALANCE and RUGGEDCOM Devices Use After Free (CVE-2024-53194)
PCI: vulnerability causes a use-after-free error during hot removal of a USB4 dock due to improper handling of pcislot and pcibus references, which is fixed by ensuring pcislot acquires a reference to pcibus. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40947)
ima: Avoid blocking in RCU read-side critical section, a panic happens in imamatchpolicy. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504587;...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46719)
usb: typec: ucsi: Fix null pointer dereference in trace ucsiregisteraltmode checks ISERR for the alt pointer and treats NULL as valid. When CONFIGTYPECDPALTMODE is not enabled, ucsiregisterdisplayport returns NULL which causes a NULL pointer dereference in trace. Rather than return NULL, call...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-43867)
drm/nouveau: prime: refcount underflow. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504678; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42077)
ocfs2: DIO failure due to insufficient transaction credits. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504618; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Divide By Zero (CVE-2024-56567)
ad7780: division by zero in ad7780writeraw In the ad7780writeraw , val2 can be zero, which might lead to a division by zero error in DIVROUNDCLOSEST. The ad7780writeraw is based on iioinfo's writeraw. While val is explicitly declared that can be zero in read mode, val2 is not specified to be...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42092)
gpio: davinci: There can be out of chips-irqs array boundaries access in davincigpioprobe. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504610;...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46702)
thunderbolt: Mark XDomain as unplugged when router is removed. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504670; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') (CVE-2024-40902)
jfs: xattr: buffer overflow for invalid xattr. When an xattr size is not what is expected, it is printed out to the kernel log in hex format as a form of debugging. But when that xattr size is bigger than the expected size, printing it out can cause an access off the end of the buffer. This plugi...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53148)
comedi: Flush partial mappings in error case If some remappfnrange calls succeeded before one failed, we still have buffer pages mapped into the userspace page tables when we drop the buffer reference with comedibufmapputbm. The userspace mappings are only cleaned up later in the mmap error path...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56558)
nfsd: make sure exp active before svcexportshow The function eshow was called with protection from RCU. This only ensures that exp will not be freed. Therefore, the reference count for exp can drop to zero, which will trigger a refcount use-after-free warning when expget is called. This plugin on...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-45025)
bitmap corruption on closerange with CLOSERANGEUNSHARE copyfdbitmaps. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504655; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46763)
fou: null-ptr-deref in GRO. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504704; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Use After Free (CVE-2024-49936)
net/xen-netback: prevent UAF in xenvifflushhash. During the listforeachentryrcu iteration call of xenvifflushhash, kfreercu does not exist inside the rcu read critical section, so if kfreercu is called when the rcu grace period ends during the iteration, UAF occurs when accessing head-next after...