195 matches found
CISA Releases Five Industrial Control Systems Advisories
CISA released five Industrial Control Systems ICS advisories on May 8, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-128-01 Horner Automation Cscape ICSA-25-128-02 Hitachi Energy RTU500 series ICSA-25-128-03...
Exploit for Improper Certificate Validation in Hitachienergy Rtu500_Scripting_Interface
CVE-2023-1514-S...
Hitachi Energy's RTU500 series Insufficient Resource Pool (CVE-2024-12169)
A vulnerability exists in RTU500 IEC 60870-5-104 con- trolled station functionality and IEC 61850 functional- ity, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerabil- ity only applies, if secure communication using IEC 62351-3 TLS is enabled...
Hitachi Energy's RTU500 series Missing synchronization (CVE-2025-1445)
A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active. Precondition is that IEC61850 as client or server are...
Hitachi Energy's RTU500 series NULL Pointer Deference (CVE-2024-11499)
A vulnerability exists in RTU500 IEC 60870-4-104 con- trolled station functionality, that allows an authenti- cated and authorized attacker to perform a CMU re- start. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will...
Hitachi Energy's RTU500 series NULL Pointer Deference (CVE-2024-10037)
A vulnerability exists in the RTU500 web server com- ponent that can cause a denial of service to the RTU500 CMU application if a specially crafted mes- sage sequence is executed on a WebSocket connec- tion. An attacker must be properly authenticated and the test mode function of RTU500 must be...
CISA Releases Five Industrial Control Systems Advisories
CISA released five Industrial Control Systems ICS advisories on April 3, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-093-01 Hitachi Energy RTU500 Series ICSA-25-093-02 Hitachi Energy TRMTracker...
CVE-2024-11499
A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will automatically...
CVE-2025-1445
A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active. Precondition is that IEC61850 as client or server are...
CVE-2024-12169
A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 TLS is enabled...
CVE-2024-10037
A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequence is executed on a WebSocket connection. An attacker must be properly authenticated and the test mode function of RTU500 must be enabled...
CVE-2025-1445
A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active. Precondition is that IEC61850 as client or server are...
CVE-2024-12169
A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 TLS is enabled...
CVE-2024-10037
A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequence is executed on a WebSocket connection. An attacker must be properly authenticated and the test mode function of RTU500 must be enabled...
CVE-2024-11499
A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will automatically...
CVE-2024-12169
A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 TLS is enabled...
CVE-2024-12169
The CVE-2024-12169 entry involves Hitachi Energy RTU500 series, affecting the RTU500 IEC 60870-5-104 controlled-station functionality and IEC 61850 functionality. The described impact is that an attacker performing a specific attack sequence can restart the affected CMU, and this only applies whe...
CVE-2024-12169
A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 TLS is enabled...
CVE-2024-11499
CVE-2024-11499 – Hitachi Energy RTU500 : The RTU500 IEC 60870-4-104 controlled-station functionality is affected. An authenticated and authorized attacker can trigger a CMU restart by updating certificates while they are in use on active connections. The affected CMU is described as automatically...
CVE-2024-11499
A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will automatically...