195 matches found
EUVD-2024-54339
Malicious code in bioql PyPI...
EUVD-2024-54517
Malicious code in bioql PyPI...
EUVD-2022-34760
Malicious code in bioql PyPI...
EUVD-2023-58050
Malicious code in bioql PyPI...
EUVD-2022-33055
Malicious code in bioql PyPI...
EUVD-2022-34371
Malicious code in bioql PyPI...
EUVD-2024-17279
Malicious code in bioql PyPI...
EUVD-2024-54521
Malicious code in bioql PyPI...
EUVD-2023-58051
Malicious code in bioql PyPI...
EUVD-2022-51940
Malicious code in bioql PyPI...
EUVD-2023-58931
Malicious code in bioql PyPI...
EUVD-2024-17280
Malicious code in bioql PyPI...
EUVD-2024-27566
Malicious code in bioql PyPI...
EUVD-2023-58052
Malicious code in bioql PyPI...
CISA Releases Six Industrial Control Systems Advisories
CISA released six Industrial Control Systems ICS advisories on September 23, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-266-01 AutomationDirect CLICK PLUS ICSA-25-266-02 Mitsubishi Electric MELSEC-Q Serie...
Hitachi Energy RTU500 series
RISK EVALUATION Successful exploitation of these vulnerabilities could cause a Denial-of-Service condition in RTU500 devices. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure...
CVE-2024-1532
A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below. A malicious actor could enforce diagnostic texts being displayed as empty strings, if an authorized user uploads a specially crafted stb-language file...
CVE-2023-6711
Vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Specially crafted messages sent to the mentioned components are not validated properly and can result in buffer overflow and as final consequence to a reboot of an...
CVE-2023-5768
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length...
CVE-2023-1514
A vulnerability exists in the component RTU500 Scripting interface. When a client connects to a server using TLS, the server presents a certificate. This certificate links a public key to the identity of the service and is signed by a Certification Authority CA, allowing the client to validate th...