Lucene search
K

7 matches found

Tenable Nessus
Tenable Nessus
added 2023/03/29 12:0 a.m.17 views

WAGO PFC200 Series Improper Authentication (CVE-2018-5459)

An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker...

9.8CVSS8.8AI score0.02684EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 2018/04/03 1:29 p.m.2 views

CVE-2018-8836

Wago 750 Series PLCs with firmware version 10 and prior include a remote attack may take advantage of an improper implementation of the 3 way handshake during a TCP connection affecting the communications with commission and service tools. Specially crafted packets may also be sent to Port...

5.3CVSS5.5AI score0.03626EPSS
Exploits0References4Affected Software1
Prion
Prion
added 2018/04/03 1:29 p.m.20 views

Design/Logic Flaw

Wago 750 Series PLCs with firmware version 10 and prior include a remote attack may take advantage of an improper implementation of the 3 way handshake during a TCP connection affecting the communications with commission and service tools. Specially crafted packets may also be sent to Port...

5CVSS5.2AI score0.03626EPSS
Exploits0References3Affected Software8
CNVD
CNVD
added 2018/02/26 12:0 a.m.3 views

WAGO PFC200 Series Incorrect Authentication Vulnerability

The WAGO PFC200 is a bus editable logic controller module from WAGO Germany. An incorrect authentication vulnerability exists in the WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. The vulnerability originates from the CoDeSys Runtime application being available by default over th...

9.8CVSS7.5AI score0.02684EPSS
Exploits0References1
OSV
OSV
added 2018/02/13 9:29 p.m.2 views

CVE-2018-5459

An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker...

9.8CVSS6AI score0.02684EPSS
Exploits0References1
Cvelist
Cvelist
added 2018/02/13 9:0 p.m.20 views

CVE-2018-5459

An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker...

9.8AI score0.02684EPSS
Exploits0References1
ICS
ICS
added 2018/02/13 12:0 a.m.39 views

WAGO PFC200 Series

CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Public exploits are available. Vendor: WAGO Equipment: PFC200 Series Vulnerability: Improper Authentication UPDATE INFORMATION This advisory is a follow-up to the alert titled ICS-ALERT-17-341-01 WAGO PFC200 that was publishe...

9.8CVSS10AI score0.02684EPSS
Exploits0References5
Rows per page
Query Builder