Lucene search
+L

520 matches found

CVE
CVE
added 2021/05/12 1:18 p.m.85 views

CVE-2021-25660

The CVE-2021-25660 entry maps to Siemens SmartVNC/WinCC/HMI components with an out-of-bounds memory access vulnerability that can trigger a Denial-of-Service on the server side (and related variants on the client side). Affected products include SIMATIC HMI Comfort Outdoor Panels (various V15/V16...

7.5CVSS7.3AI score0.00961EPSS
Exploits0References1Affected Software1
CVE
CVE
added 2021/05/12 1:18 p.m.74 views

CVE-2021-25661

CVE-2021-25661 is an out-of-bounds memory access vulnerability in SmartVNC that can be triggered on the client side when data is sent from the server, potentially causing a Denial-of-Service. Affected products include SIMATIC WinCC Runtime Advanced and related HMI/SU panels (Outdoor Panels v15/v1...

7.5CVSS7.3AI score0.01138EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2021/05/12 1:18 p.m.52 views

CVE-2019-19276

CVE-2019-19276 affects Siemens SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS) and SIMATIC HMI KTP Mobile Panels, all versions prior to version 16 update 4. The root cause is an out-of-bounds write (CWE-787) triggered by specially crafted UDP packets to port 161, causing the SNMP service...

5.3CVSS5.2AI score0.0102EPSS
Exploits0References1Affected Software1
BDU FSTEC
BDU FSTEC
added 2021/05/05 12:0 a.m.11 views

The vulnerability of Mitsubishi Electric’s graphic control panel software for the GOT2000 and GOT SIMPLE series lies in authentication errors, allowing attackers to gain unauthorized access to protected information.

The vulnerability of Mitsubishi Electric’s GOT2000 and GOT SIMPLE graphic control panels relates to authentication errors. Exploiting this vulnerability can allow an attacker to gain unauthorized access to protected information...

5.9CVSS7.2AI score0.01275EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2021/03/30 12:0 a.m.5 views

The vulnerability in the web administration panel of Netgear ProSafe Plus JGS516PE and ProSAFE Plus GS116Ev2 microprogrammed network devices allows a hacker to perform cross-site scripting attacks.

The vulnerability of the web administration panel of Netgear ProSafe Plus JGS516PE and ProSAFE Plus GS116Ev2 networking devices is related to the lack of measures taken to protect the website structure. Exploiting this vulnerability allows a malicious actor to perform cross-site scripting attacks...

4.8CVSS5.3AI score0.00828EPSS
Exploits0References4Affected Software2
NVD
NVD
added 2021/02/09 5:15 p.m.44 views

CVE-2020-15798

A vulnerability has been identified in SIMATIC HMI Comfort Panels incl. SIPLUS variants All versions V16 Update 3a, SIMATIC HMI KTP Mobile Panels All versions V16 Update 3a, SINAMICS GH150 All versions, SINAMICS GL150 with option X30 All versions, SINAMICS GM150 with option X30 All versions,...

9.8CVSS0.05176EPSS
Exploits0References3
OSV
OSV
added 2021/02/09 5:15 p.m.8 views

CVE-2020-15798

A vulnerability has been identified in SIMATIC HMI Comfort Panels incl. SIPLUS variants All versions V16 Update 3a, SIMATIC HMI KTP Mobile Panels All versions V16 Update 3a, SINAMICS GH150 All versions, SINAMICS GL150 with option X30 All versions, SINAMICS GM150 with option X30 All versions,...

9.8CVSS7.2AI score0.05176EPSS
Exploits0References3
Vulnrichment
Vulnrichment
added 2021/02/09 3:38 p.m.9 views

CVE-2020-15798

A vulnerability has been identified in SIMATIC HMI Comfort Panels incl. SIPLUS variants All versions V16 Update 3a, SIMATIC HMI KTP Mobile Panels All versions V16 Update 3a, SINAMICS GH150 All versions, SINAMICS GL150 with option X30 All versions, SINAMICS GM150 with option X30 All versions,...

7.2AI score0.05176EPSS
Exploits0References3
CVE
CVE
added 2021/02/09 3:38 p.m.66 views

CVE-2020-15798

CVE-2020-15798 affects Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS) and SIMATIC HMI KTP Mobile Panels, plus several SINAMICS models (GH150, GL150 X30, GM150 X30, SH150, SL150, SM120, SM150, SM150i). The vulnerability arises from the Telnet service not requiring authentication, allowing a rem...

9.8CVSS9.5AI score0.05176EPSS
Exploits0References3Affected Software1
CNNVD
CNNVD
added 2021/01/26 12:0 a.m.7 views

Bosch FSM-2500 server 和 Bosch FSM-5000 server 信任管理问题漏洞

Bosch FSM-2500 and Bosch FSM-5000 are both panel-ready fire control systems from Bosch of Germany. Bosch FSM-2500 and Bosch FSM-5000 suffer from a hard-coded vulnerability that could be exploited by remote attackers to submit special requests to gain unauthorized access to the database system wit...

10CVSS7.3AI score0.03696EPSS
Exploits0References2
CNNVD
CNNVD
added 2021/01/26 12:0 a.m.8 views

Bosch FSM-2500 和 Bosch FSM-5000 访问控制错误漏洞

Bosch FSM-2500 and Bosch FSM-5000 are both panel-ready fire control systems from Bosch of Germany. Bosch FSM-2500 and Bosch FSM-5000 are vulnerable to a password disclosure vulnerability that could be exploited by a remote attacker to submit a special request that could gain access to sensitive...

4.9CVSS5.8AI score0.00561EPSS
Exploits0References2
CNVD
CNVD
added 2021/01/22 12:0 a.m.9 views

TPEditor Out-of-Bounds Write Vulnerability

TPEditor is programming software for Delta Text Panels running on Windows. An out-of-bounds write vulnerability exists in TPEditor 1.98 and earlier versions. An attacker can exploit this vulnerability to execute arbitrary code via specially crafted project files...

7.8CVSS7.7AI score0.01191EPSS
Exploits0References1
BDU FSTEC
BDU FSTEC
added 2020/12/24 12:0 a.m.4 views

The vulnerability of the CmtViewer application, which manages programmable panels, stems from the lack of limits on authentication attempts. This allows a perpetrator to gain full access to the device.

The vulnerability of the CmtViewer application for controlling programmable panels is related to the lack of restrictions on the number of authentication attempts. Exploiting this vulnerability could allow a malicious actor, operating remotely, to gain full access to the device...

10CVSS5.5AI score
Exploits0
BDU FSTEC
BDU FSTEC
added 2020/12/24 12:0 a.m.5 views

The vulnerability of the CmtViewer application, which involves session management errors, allows a hacker to gain unauthorized access.

The vulnerability of the CmtViewer application for controlling programmable panels is related to session management errors. Exploiting this vulnerability can allow a remote attacker to gain unauthorized access by intercepting the session...

10CVSS5.5AI score
Exploits0
BDU FSTEC
BDU FSTEC
added 2020/12/24 12:0 a.m.8 views

The vulnerability of the CmtViewer application, which manages programmable panels, stems from the storage of protected information in an unencrypted form. This allows a perpetrator to gain access to the protected information.

The vulnerability of the CmtViewer application for controlling programmable panels lies in the storage of protected information in an unencrypted form. Exploiting this vulnerability could allow a malicious actor to gain access to the protected information remotely...

10CVSS5.4AI score
Exploits0
Kitploit
Kitploit
added 2020/12/02 8:30 p.m.53 views

Fast-Security-Scanners - Security Checks For Your Researches

A small contribution to community : We use all these tools in security assessments and in our vulnerability monitoring service Check your domain for DNS NStakeover Repo docker run --dns=8.8.8.8 -e VULNID=dnsnstakeover -e DOMAIN=site.com whitespots/dnsnstakeover CachePoisoning Repo docker run --rm...

7.2AI score
Exploits0References9
Cvelist
Cvelist
added 2020/12/02 2:39 p.m.27 views

CVE-2020-12524 Phoenix Contact BTP Touch Panels uncontrolled resource consumption

Uncontrolled Resource Consumption can be exploited to cause the Phoenix Contact HMIs BTP 2043W, BTP 2070W and BTP 2102W in all versions to become unresponsive and not accurately update the display content Denial of Service...

7.5CVSS7.5AI score0.0107EPSS
Exploits0References1
Openbugbounty
Openbugbounty
added 2020/09/23 12:58 p.m.8 views

georgebarberpanels.co.uk Cross Site Scripting vulnerability OBB-1358739

Following coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: &nbsp&nbsp&nbsp&nbsp&nbsp&nbspa. verified the vulnerability and confirmed its existence; &nbsp&nbsp&nbsp&nbsp&nbsp&nbspb. notified the website operator about its existence...

6.2AI score
Exploits0
RedHat Linux
RedHat Linux
added 2020/09/10 7:30 a.m.57 views

Important: Red Hat Security Advisory: openstack-nova security update

An update for openstack-nova is now available for Red Hat OpenStack Platform 13 Queens. Red Hat Product Security has rated this update as having a security impact of Important. A Common Vulnerability Scoring System CVSS base score, which gives a detailed severity rating, is available for each...

8.3CVSS7.2AI score0.01715EPSS
Exploits1References2
OSV
OSV
added 2020/09/09 7:15 p.m.5 views

CVE-2020-15786

A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation incl. SIPLUS variants All versions V16, SIMATIC HMI Comfort Panels incl. SIPLUS variants All versions = V16, SIMATIC HMI Mobile Panels All versions = V16, SIMATIC HMI Unified Comfort Panels All versions = V16. Affected...

9.8CVSS5.7AI score
Exploits0References1
Rows per page
Query Builder