Lucene search
+L

12852 matches found

OSV
OSV
added 2021/08/02 1:15 p.m.9 views

CVE-2021-37166

A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and...

7.5CVSS7.5AI score0.02062EPSS
SaveExploits0References4
NVD
NVD
added 2021/08/02 1:15 p.m.31 views

CVE-2021-37166

A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and...

7.8CVSS0.02062EPSS
SaveExploits0References4
NVD
NVD
added 2021/08/02 1:15 p.m.27 views

CVE-2021-37167

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...

10CVSS0.01737EPSS
SaveExploits0References4
ATTACKERKB
ATTACKERKB
added 2021/08/02 1:15 p.m.5 views

CVE-2021-37166

A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and...

7.8CVSS7.4AI score0.02062EPSS
SaveExploits0References6
ATTACKERKB
ATTACKERKB
added 2021/08/02 1:15 p.m.7 views

CVE-2021-37164

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...

9.8CVSS7.9AI score0.03396EPSS
SaveExploits0References6
Prion
Prion
added 2021/08/02 1:15 p.m.26 views

Buffer overflow

A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...

7.5CVSS9.8AI score0.03264EPSS
SaveExploits0References4Affected Software1
ATTACKERKB
ATTACKERKB
added 2021/08/02 1:15 p.m.10 views

CVE-2021-37161

A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...

9.8CVSS7.8AI score0.03396EPSS
SaveExploits0References6
Prion
Prion
added 2021/08/02 1:15 p.m.28 views

Stack overflow

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...

7.5CVSS9.5AI score0.03396EPSS
SaveExploits0References4Affected Software1
Prion
Prion
added 2021/08/02 1:15 p.m.40 views

Buffer overflow

A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and...

7.8CVSS7.9AI score0.02062EPSS
SaveExploits0References4Affected Software1
ATTACKERKB
ATTACKERKB
added 2021/08/02 1:15 p.m.5 views

CVE-2021-37163

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...

9.8CVSS7.4AI score0.01439EPSS
SaveExploits0References6
Prion
Prion
added 2021/08/02 1:15 p.m.33 views

Default credentials

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...

10CVSS9.5AI score0.01737EPSS
SaveExploits0References4Affected Software1
Prion
Prion
added 2021/08/02 1:15 p.m.29 views

Input validation

A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...

7.5CVSS9.4AI score0.08227EPSS
SaveExploits0References4Affected Software1
Prion
Prion
added 2021/08/02 1:15 p.m.29 views

Buffer overflow

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...

7.5CVSS9.8AI score0.03264EPSS
SaveExploits0References4Affected Software1
ATTACKERKB
ATTACKERKB
added 2021/08/02 1:15 p.m.7 views

CVE-2021-37160

A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...

9.8CVSS7.4AI score0.08227EPSS
SaveExploits0References6
ATTACKERKB
ATTACKERKB
added 2021/08/02 1:15 p.m.8 views

CVE-2021-37162

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...

9.8CVSS7.9AI score0.03396EPSS
SaveExploits0References6
CVE
CVE
added 2021/08/02 12:49 p.m.114 views

CVE-2021-37162

Technical details for CVE-2021-37162 are not publicly available in the provided connected documents. Monitor for updates.

9.8CVSS9.9AI score0.03396EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
added 2021/08/02 12:49 p.m.45 views

CVE-2021-37162

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...

10AI score0.03396EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2021/08/02 12:47 p.m.47 views

CVE-2021-37164

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...

9.8AI score0.03396EPSS
SaveExploits0References4
CVE
CVE
added 2021/08/02 12:47 p.m.101 views

CVE-2021-37164

The CVE-2021-37164 issue affects Swisslog Healthcare Nexus Control Panel (Nexus Panel). A stack-based buffer overflow is caused by an out-of-bounds write in tcpTxThread when processing received data, affecting released versions before Nexus Software 7.2.5.7. CNVD-2021-62178 confirms an out-of-bou...

9.8CVSS9.5AI score0.03396EPSS
SaveExploits0References4Affected Software1
CVE
CVE
added 2021/08/02 12:46 p.m.93 views

CVE-2021-37163

CVE-2021-37163 affects Swisslog Healthcare Nexus HMI3 Control Panel (Nexus software before 7.2.5.7). The device has two hardcoded passwords and an insecure permissions issue, enabling potential unauthorized access over the network. Impact details are described as high/severe in the CVSS metrics. ...

9.8CVSS9.4AI score0.03396EPSS
SaveExploits0References4Affected Software1
Rows per page