Nexus Control Panel Elevation of Privilege Vulnerability
Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.An elevation of privilege vulnerability exists in versions prior to Nexus Control Panel 7.2.5.7. An attacker could exploit this vulnerability to gain root access to the device, which would allow access to all device...
CVE-2021-36622
Sourcecodester Online Covid Vaccination Scheduler System 1.0 is affected vulnerable to Arbitrary File Upload. The admin panel has an upload function of profile photo accessible at http://localhost/scheduler/admin/?page=user. An attacker could upload a malicious file such as shell.php with the...
CVE-2021-36622
Sourcecodester Online Covid Vaccination Scheduler System 1.0 is affected vulnerable to Arbitrary File Upload. The admin panel has an upload function of profile photo accessible at http://localhost/scheduler/admin/?page=user. An attacker could upload a malicious file such as shell.php with the...
Design/Logic Flaw
Sourcecodester Online Covid Vaccination Scheduler System 1.0 is affected vulnerable to Arbitrary File Upload. The admin panel has an upload function of profile photo accessible at http://localhost/scheduler/admin/?page=user. An attacker could upload a malicious file such as shell.php with the...
CVE-2021-36622
Sourcecodester Online Covid Vaccination Scheduler System 1.0 is affected vulnerable to Arbitrary File Upload. The admin panel has an upload function of profile photo accessible at http://localhost/scheduler/admin/?page=user. An attacker could upload a malicious file such as shell.php with the...
Major Hospitals affected by PwnedPiper Vulnerabilities
THREAT LEVEL: White. For a detailed advisory, download the pdf file here. Multiple Zero-day vulnerabilities PwnedPiper have been found affecting the HMI-3 Control Panel of Swisslog Healthcare’s TransLogic Pneumatic Tube Systems PTS. PTS is a specialized system that uses compressor to transport...
Hotel Management System 1.0 - Cross-Site Scripting (XSS) Arbitrary File Upload Remote Code Execution (RCE)
Exploit Title: Hotel Management System 1.0 - Cross-Site Scripting XSS Arbitrary File Upload Remote Code Execution RCE Date: 2021-08-01 Exploit Author: Merbin Russel Vendor Homepage: https://phpgurukul.com/ Software Link: https://phpgurukul.com/?smdprocessdownload=1&downloadid=7204 Version: V1.0...
Swisslog Healthcare Translogic PTS
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Swisslog Healthcare Equipment: Translogic PTS Pneumatic Tube Systems Vulnerabilities: Use of Hard-coded Password, Execution with Unnecessary Privileges, Improper Authentication, Download of Code without...
CVE-2021-37163
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...
CVE-2021-37164
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...
CVE-2021-37160
A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...
CVE-2021-37161
A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...
CVE-2021-37163
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...
CVE-2021-37160
A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...
CVE-2021-37161
A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...
CVE-2021-37162
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...
CVE-2021-37164
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...
CVE-2021-37167
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...
CVE-2021-37162
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...
CVE-2021-37166
A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and...