Lucene search
+L

175 matches found

CVE
CVE
•added 2018/12/13 4:00 p.m.•94 views

CVE-2018-16556

CVE-2018-16556 affects Siemens SIMATIC S7-400 family CPUs (multiple models). Root cause: specially crafted packets sent to port 102/tcp (Ethernet, PROFIBUS, MPI) can cause devices to enter defect mode, requiring a manual reboot. Exploitation requires network access with no user interaction; impac...

7.8CVSS7.2AI score0.01545EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/13 12:00 a.m.•3 views

CVE-2018-16556: Improper Input Validation

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 All versions, SIMATIC S7-400 CPU 412-2 DP V7 All versions, SIMATIC S7-400 CPU 414-2 DP V7 All versions, SIMATIC S7-400 CPU 414-3 DP V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions V7.0.3, SIMATIC S7-400 CPU 414F...

7.8CVSS5.6AI score0.01545EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/13 12:00 a.m.•1 views

CVE-2018-16557: Improper Verification of Cryptographic Signature

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 All versions, SIMATIC S7-400 CPU 412-2 DP V7 All versions, SIMATIC S7-400 CPU 414-2 DP V7 All versions, SIMATIC S7-400 CPU 414-3 DP V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions V7.0.3, SIMATIC S7-400 CPU 414F...

8.2CVSS5.7AI score0.00821EPSS
SaveExploits0References2
CNVD
CNVD
•added 2018/11/16 12:00 a.m.•15 views

Siemens SIMATIC S7-400 Input Validation Vulnerability

Siemens SIMATIC S7-400 is a programmable logic controller for manufacturing and process automation from Siemens, Germany. An input validation vulnerability exists in the Siemens SIMATIC S7-400 product, which can be exploited by an attacker to cause a service crash via a specially crafted packet...

7.8CVSS7.3AI score0.01545EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2018/11/13 12:00 a.m.•12 views

PT-2018-2566 · Siemens · Simatic S7-400 Cpu 416-2 Dp V7 +14

Name of the Vulnerable Software and Affected Versions: SIMATIC S7-400 CPU 412-1 DP V7 All versions SIMATIC S7-400 CPU 412-2 DP V7 All versions SIMATIC S7-400 CPU 412-2 PN V7 All versions V7.0.3 SIMATIC S7-400 CPU 414-2 DP V7 All versions SIMATIC S7-400 CPU 414-3 DP V7 All versions SIMATIC S7-400...

7.8CVSS7.3AI score0.01545EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
•added 2018/05/25 12:00 a.m.•13 views

The vulnerability of the PROFIBUS-Ethernet gateway Softing AG FG-100 PB lies in the use of pre-set credentials, allowing a intruder to gain access to the device with root privileges.

The vulnerability of the PROFIBUS-Ethernet gateway Softing AG FG-100 PB lies in the use of pre-set credentials. Exploiting this vulnerability could allow a malicious actor, operating remotely, to gain access to the device with root privileges through a Telnet connection...

10CVSS5.5AI score0.04369EPSS
SaveExploits2References7
NVD
NVD
•added 2018/03/09 8:29 p.m.•19 views

CVE-2014-6617

Softing FG-100 PB PROFIBUS firmware version FG-x00-PBV2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session...

10CVSS9.4AI score0.04369EPSS
SaveExploits2References5
Prion
Prion
•added 2018/03/09 8:29 p.m.•20 views

Hardcoded credentials

Softing FG-100 PB PROFIBUS firmware version FG-x00-PBV2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session...

10CVSS7.4AI score0.04369EPSS
SaveExploits2References5Affected Software1
CVE
CVE
•added 2018/03/09 8:00 p.m.•51 views

CVE-2014-6617

The CVE-2014-6617 entry applies to Softing FG-100 PB PROFIBUS firmware FG-x00-PB_V2.02.0.00, where a hardcoded root password enables TELNET access to obtain admin rights. Public documents (NVD entry and Compass Security advisory) confirm a backdoor account exists by default, with vendor notes ind...

10CVSS9.3AI score0.04369EPSS
SaveExploits2References5Affected Software1
Cvelist
Cvelist
•added 2018/03/09 8:00 p.m.•30 views

CVE-2014-6617

Softing FG-100 PB PROFIBUS firmware version FG-x00-PBV2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session...

9.5AI score0.04369EPSS
SaveExploits2References5
OpenVAS
OpenVAS
•added 2017/08/18 12:00 a.m.•68 views

Siemens SIMATIC S7 PLC Multiple Vulnerabilities (SSA-293562)

Siemens SIMATIC S7 devices are prone to multiple vulnerabilities. Copyright C 2017 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later This program is free...

7.1CVSS6.7AI score0.01149EPSS
SaveExploits0References2
OSV
OSV
•added 2017/05/11 10:29 a.m.•7 views

CVE-2017-2681

Specially crafted PROFINET DCP packets sent on a local Ethernet segment Layer 2 to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected...

6.5CVSS5.8AI score0.00906EPSS
SaveExploits0References5
NVD
NVD
•added 2017/05/11 10:29 a.m.•21 views

CVE-2017-2681

Specially crafted PROFINET DCP packets sent on a local Ethernet segment Layer 2 to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected...

7.1CVSS6.2AI score0.00906EPSS
SaveExploits0References5
OSV
OSV
•added 2017/05/11 1:29 a.m.•8 views

CVE-2017-2680

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment Layer 2. Human interaction is required to recover the systems. PROFIBUS interfaces are not affected...

6.5CVSS5.8AI score0.01149EPSS
SaveExploits0References10
Prion
Prion
•added 2017/05/11 1:29 a.m.•25 views

Design/Logic Flaw

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment Layer 2. Human interaction is required to recover the systems. PROFIBUS interfaces are not affected...

6.1CVSS6.2AI score0.01149EPSS
SaveExploits0References7Affected Software78
Positive Technologies
Positive Technologies
•added 2017/05/08 12:00 a.m.•11 views

PT-2017-3762 · Siemens · Profinet Dcp

Name of the Vulnerable Software and Affected Versions: Siemens PROFINET DCP affected versions not specified Description: The issue is related to insufficient input validation in the PROFINET DCP software, which can be exploited by an attacker using specially crafted PROFINET DCP broadcast packets...

7.1CVSS6.3AI score0.01149EPSS
SaveExploits0References15
Prion
Prion
•added 2016/12/17 3:59 a.m.•26 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...

4.3CVSS6.9AI score0.01538EPSS
SaveExploits0References5
NVD
NVD
•added 2016/12/17 3:59 a.m.•23 views

CVE-2016-9159

A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...

5.9CVSS6.5AI score0.01538EPSS
SaveExploits0References5
CVE
CVE
•added 2016/12/17 3:34 a.m.•88 views

CVE-2016-9159

The vulnerability CVE-2016-9159 affects Siemens SIMATIC S7-300/400 PLC families (including related ET200/SIPLUS variants) where an attacker with network access to port 102/TCP (ISO-TSAP) or via Profibus can obtain credentials if protection-level 2 is configured. The ICS-CISA advisory SSA-731239 d...

5.9CVSS6.1AI score0.01538EPSS
SaveExploits0References5Affected Software1
Cvelist
Cvelist
•added 2016/12/17 3:34 a.m.•47 views

CVE-2016-9159

A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...

6.4AI score0.01538EPSS
SaveExploits0References5
Rows per page