Lucene search
+L

3063 matches found

CNVD
CNVD
added 2020/09/25 12:0 a.m.2 views

SIMATIC S7-300 has a Denial of Service Vulnerability

The S7-300 is a modular compact PLC system. A denial of service vulnerability exists in SIMATIC S7-300, which can be exploited by an attacker to cause a denial of service to the server...

6.8AI score
SaveExploits0
CNVD
CNVD
added 2020/09/23 12:0 a.m.4 views

Denial of Service Vulnerability in Omron Small PLC Series CP1L

CP1L is Omron's compact PLC series, an all-in-one PLC with built-in pulse output, analog input/output, and serial communication functions. A denial of service vulnerability exists in the Omron compact PLC series CP1L, which can be exploited by an attacker to stop programs running on the device...

6.8AI score
SaveExploits0
Zero Day Initiative
Zero Day Initiative
added 2020/09/14 12:0 a.m.32 views

(0Day) Fatek Automation PLC WinProladder TAB File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fatek Automation PLC WinProladder. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within...

7.8CVSS5.2AI score
SaveExploits0
Zero Day Initiative
Zero Day Initiative
added 2020/09/14 12:0 a.m.34 views

(0Day) Fatek Automation PLC WinProladder SPF File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fatek Automation PLC WinProladder. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within...

7.8CVSS5.5AI score
SaveExploits0
ICS
ICS
added 2020/09/10 12:0 a.m.71 views

FATEK Automation PLC WinProladder

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: FATEK Automation Equipment: PLC WinProladder Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the device being accessed; a buffer overflow...

7.8CVSS8.4AI score0.01299EPSS
SaveExploits0References6
NVD
NVD
added 2020/09/09 7:15 p.m.32 views

CVE-2020-15791

A vulnerability has been identified in SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 CPU family incl. SIPLUS variants All versions, SIMATIC WinAC RTX F 2010 All versions, SINUMERIK 840D sl All versions. The authentication protocol between a...

6.5CVSS0.00718EPSS
SaveExploits0References1
CVE
CVE
added 2020/09/09 6:13 p.m.66 views

CVE-2020-15791

The CVE-2020-15791 entry describes an authentication vulnerability affecting Siemens SIMATIC S7-300/S7-400 CPU families (including related ET200, SIPLUS variants), SIMATIC WinAC RTX (F) 2010, and SINUMERIK 840D sl (all versions). The root cause is an insufficiently protected password in the ISO-T...

6.5CVSS6.4AI score0.00718EPSS
SaveExploits0References1Affected Software1
Metasploit
Metasploit
added 2020/09/09 5:40 p.m.224 views

Modbus Banner Grabbing

This module grabs the banner of any device running the Modbus protocol by sending a request with Modbus Function Code 43 Read Device Identification. Modbus is a data communications protocol originally published by Modicon now Schneider Electric in 1979 for use with its programmable logic...

7.1AI score
SaveExploits0
NVD
NVD
added 2020/09/01 2:15 p.m.28 views

CVE-2020-14514

All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements...

4.3CVSS4.6AI score0.00465EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/09/01 2:0 p.m.32 views

CVE-2020-14514 Trailer Power Line Communications vulnerability

All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements...

4.3CVSS4.7AI score0.00465EPSS
SaveExploits0References1
CVE
CVE
added 2020/09/01 2:0 p.m.49 views

CVE-2020-14514

CVE-2020-14514 affects all trailer Power Line Communications PLC buses. The issue: PLC bus traffic can be sniffed with an active antenna up to 6 feet away (potentially farther depending on environment), exposing confidential data from trailer ECUs. The CVSS v3.1 base score is 4.3 (Medium) with AV...

4.3CVSS4.6AI score0.00465EPSS
SaveExploits0References1Affected Software1
CNVD
CNVD
added 2020/07/23 12:0 a.m.4 views

Denial of Service Vulnerability in Mitsubishi Electric Corporation GX Works2 (CNVD-2020-49074 )

GX Work2 is a PLC programming software developed by Mitsubishi Electric Automation Co., Ltd. for PLC design, debugging, maintenance and other work, which is widely used in electric power, machinery manufacturing, iron and steel, petroleum, chemical and other industrial control fields. A denial of...

6.8AI score
SaveExploits0
CNVD
CNVD
added 2020/07/23 12:0 a.m.2 views

Denial of Service Vulnerability in Mitsubishi Electric Corporation GX Works2 (CNVD-2020-49072 )

GX Work2 is a PLC programming software developed by Mitsubishi Electric Automation Co., Ltd. for PLC design, debugging, maintenance and other work, which is widely used in electric power, machinery manufacturing, iron and steel, petroleum, chemical and other industrial control fields. A denial of...

6.8AI score
SaveExploits0
CNVD
CNVD
added 2020/07/23 12:0 a.m.3 views

Denial of Service Vulnerability in Mitsubishi Electric Corporation GX Works2 (CNVD-2020-49073)

GX Work2 is a PLC programming software developed by Mitsubishi Electric Automation Co., Ltd. for PLC design, debugging, maintenance and other work, which is widely used in electric power, machinery manufacturing, iron and steel, petroleum, chemical and other industrial control fields. A denial of...

6.8AI score
SaveExploits0
Talos
Talos
added 2020/07/15 12:0 a.m.47 views

Siemens LOGO! Web Server Code Execution Vulnerability

Summary An exploitable code execution vulnerability exists in the Web Server functionality of Siemens LOGO! 1.82.02, 12/24RCE Version 0BA and 230RCE Version 0BA. A specially crafted HTTP request can cause memory corruption resulting in a code execution. An attacker can send an unauthenticated...

9.8CVSS10AI score0.09071EPSS
SaveExploits1
NVD
NVD
added 2020/06/26 5:15 p.m.34 views

CVE-2020-10628

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes unencrypted passwords on the network...

7.5CVSS0.00743EPSS
SaveExploits0References1
NVD
NVD
added 2020/06/26 5:15 p.m.38 views

CVE-2020-10624

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes a session token on the network...

7.5CVSS0.00743EPSS
SaveExploits0References1
Prion
Prion
added 2020/06/26 5:15 p.m.19 views

Design/Logic Flaw

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes a session token on the network...

5CVSS7.5AI score0.00743EPSS
SaveExploits0References1Affected Software2
Prion
Prion
added 2020/06/26 5:15 p.m.13 views

Design/Logic Flaw

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes unencrypted passwords on the network...

5CVSS7.5AI score0.00743EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2020/06/26 4:22 p.m.46 views

CVE-2020-10624

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes a session token on the network...

7.6AI score0.00743EPSS
SaveExploits0References1
Rows per page
Query Builder