Lucene search
+L

3063 matches found

Cvelist
Cvelist
added 2020/11/19 9:3 p.m.26 views

CVE-2020-28211

A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause bypass of authentication when overwriting memory using a debugger...

7.8AI score0.00327EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2020/11/19 12:0 a.m.16 views

Schneider Electric EcoStruxure Control Expert 授权问题漏洞

EcoStruxure Control Expert is the universal programming, debugging and operating software for the Modicon M340, M580, M580S, Premium, Momentum and Quantum series. A security vulnerability exists in PLC Simulator in EcoStruxure Control Expert. The vulnerability can be exploited by an attacker to...

9.8CVSS7.3AI score0.02757EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2020/11/19 12:0 a.m.14 views

Schneider Electric EcoStruxure Control Expert 权限许可和访问控制问题漏洞

Schneider Electric EcoStruxure Control Expert is the universal programming, commissioning and operating software for the Modicon M340, M580, M580S, Premium, Momentum and Quantum series. An incorrect authorization vulnerability exists in PLC Simulator in Schneider Electric EcoStruxure Control...

7.8CVSS7.2AI score0.00327EPSS
SaveExploits0References2
ThreatPost
ThreatPost
added 2020/11/12 4:52 p.m.22 views

Bugs in Critical Infrastructure Gear Allow Sophisticated Cyberattacks

Two security vulnerabilities in Schneider Electric’s programmable logic controllers PLCs could allow attackers to compromise a PLC and move on to more sophisticated critical infrastructure attacks. PLCs are key pieces of equipment in environments such as electric utilities and factories. They...

0.4AI score
SaveExploits0References11
CNVD
CNVD
added 2020/11/12 12:0 a.m.18 views

Schneider Electric EcoStruxure Control Expert PLC Denial of Service Vulnerability

Schneider Electric EcoStruxure Control Expert formerly Unity Pro is a suite of programming software for Schneider Electric logic controller products from Schneider Electric, France. A denial of service vulnerability exists in EcoStruxure Control Expert's PLC simulator, which originates when a...

7.5CVSS6.7AI score0.01288EPSS
SaveExploits0References1
Zero Day Initiative
Zero Day Initiative
added 2020/11/10 12:0 a.m.42 views

WECON PLC Editor WCP File Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of WECON PLC Editor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of WC...

7.8CVSS5.6AI score0.01972EPSS
SaveExploits0References1
Zero Day Initiative
Zero Day Initiative
added 2020/11/10 12:0 a.m.43 views

WECON PLC Editor WCP File Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of WECON PLC Editor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of WC...

7.8CVSS5.6AI score0.01972EPSS
SaveExploits0References1
ICS
ICS
added 2020/11/10 12:0 a.m.76 views

Schneider Electric PLC Simulator for EcoStruxure Control Expert

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Schneider Electric Equipment: PLC Simulator for EcoStruxure Control Expert Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this...

7.5CVSS7.8AI score0.01288EPSS
SaveExploits0References5
Zero Day Initiative
Zero Day Initiative
added 2020/11/10 12:0 a.m.34 views

WECON PLC Editor WCP File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of WECON PLC Editor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of WC...

7.8CVSS5.6AI score0.01749EPSS
SaveExploits0References1
Prion
Prion
added 2020/11/06 12:15 p.m.25 views

Design/Logic Flaw

Visual Components owned by KUKA is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds ...

5CVSS7.4AI score0.01448EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/11/06 11:20 a.m.47 views

CVE-2020-10291

CVE-2020-10291 concerns Visual Components’ network license server used by KUKA simulators. The server binds UDP port 5093 on all interfaces without authentication, exposing sensitive system information via RMS Sentinel’s license protocol. The disclosed data includes hardware/OS characteristics an...

7.5CVSS7.5AI score0.01448EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/11/06 11:20 a.m.33 views

CVE-2020-10291 RVD#3336: System information disclosure without authentication on KUKA simulators

Visual Components owned by KUKA is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds ...

7.5CVSS7.5AI score0.01448EPSS
SaveExploits0References1
ICS
ICS
added 2020/11/05 12:0 a.m.55 views

WECON PLC Editor

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: WECON Equipment: PLC Editor Vulnerabilities: Stack-based Buffer Overflow, Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code under the...

8.8CVSS9.4AI score0.01972EPSS
SaveExploits0References5
Gitee
Gitee
added 2020/11/03 2:9 p.m.10 views

isf1

This is an offensive tool for Industrial Control Systems ICS exploitation. It is a Python-based framework, similar to Metasploit, designed for ICS exploitation. The framework is called ICSSploit and is a fork of the routersploit project. The tool has various modules for different types of ICS...

7.1AI score
SaveExploits0
CNVD
CNVD
added 2020/10/07 12:0 a.m.4 views

Denial of Service Vulnerability in Schneider PLC-M580

The M580, a PLC in Schneider's Modicon PLC family, is Schneider Electric's first high-end integrated controller built for the Industrial Internet of Things architecture. A denial of service vulnerability exists in the Schneider PLC-M580, which can be exploited by an attacker to cause the PLC's...

6.8AI score
SaveExploits0References1
NVD
NVD
added 2020/09/30 9:15 p.m.28 views

CVE-2020-16234

In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code...

7.8CVSS0.01299EPSS
SaveExploits0References1
Prion
Prion
added 2020/09/30 9:15 p.m.23 views

Stack overflow

In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code...

6.8CVSS7.9AI score0.01299EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/09/30 8:44 p.m.67 views

CVE-2020-16234

CVE-2020-16234Targets PLC WinProladder, version 3.28 and earlier. A stack-based buffer overflow in the software can be triggered by opening a specially crafted file, with the potential to remotely execute arbitrary code. Public documentation lists CVSS v3 base score 7.8 (high) with LOCAL/LOW comp...

7.8CVSS8AI score0.01299EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/09/30 8:44 p.m.40 views

CVE-2020-16234 FATEK Automation PLC WinProladder

In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code...

8AI score0.01299EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/09/29 12:0 a.m.3 views

Denial of Service Vulnerability in CSC-830 of Beijing Sifang Relay Automation Company Limited (CNVD-2020-59456)

CSC830 PLC is a compact controller for small and medium-sized discrete automation systems and stand-alone automation systems from Beijing Sifang Relay Automation Co. Ltd. CSC-830 has a denial-of-service vulnerability that can be exploited by an attacker to control PLC services, affecting the norm...

6.9AI score
SaveExploits0