3063 matches found
CVE-2021-20827
Plaintext storage of a password vulnerability in IDEC PLCs FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier allows an...
CVE-2021-20826
Unprotected transport of credentials vulnerability in IDEC PLCs FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier allows...
CVE-2021-20827
Plaintext storage of a password vulnerability in IDEC PLCs FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier allows an...
IDEC PLC 安全漏洞
The IDEC PLC is a programmable controller. The IDEC PLC has a security vulnerability that can be exploited by an attacker to obtain user credentials from the communication between the PLC and the software...
IDEC PLC 安全漏洞
The IDEC PLC is a programmable controller. A security vulnerability exists in the IDEC PLC that could allow an attacker to obtain PLC web server user credentials from a file server, backup repository, or a ZLD file saved on an SD card. The following products and versions are affected: FC6A Series...
IDEC PLC 安全漏洞
The IDEC PLC is a programmable controller. A security vulnerability exists in the IDEC PLC that can be exploited by an attacker to obtain user credentials from a file server, a backup repository, or a ZLD file saved on an SD card...
CVE-2021-20608
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sendin...
Input validation
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sendin...
CVE-2021-20608
CVE-2021-20608 concerns Mitsubishi Electric GX Works2. The issue is an improper handling of a length parameter inconsistency when reading a tampered program file from a Mitsubishi PLC, which can allow a remote attacker to cause a denial of service in GX Works2. Affected products are GX Works2 ver...
CVE-2021-20608
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sendin...
PT-2021-13: Access to sensitive PLC information in FX5U(C) CPU and FX5UJ CPU modules
The vulnerability of the FX5UC CPU and FX5UJ CPU modules of Mitsubishi Electric FA products is associated with the possibility of access to sensitive PLC information. Exploiting the vulnerability may allow an attacker who has access to the project file to obtain the values of the parameters of th...
The software for programming Wecon PLC Editor on the Microsoft Windows operating system is vulnerable, allowing a hacker to execute arbitrary code.
The vulnerability of the Wecon PLC Editor software for programming PLCs on the Microsoft Windows operating system is related to buffer overflow in the stack. Exploiting this vulnerability can allow an attacker to execute arbitrary code...
CVE-2021-42707
PLC Editor Versions 1.3.8 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code...
CVE-2021-42705
PLC Editor Versions 1.3.8 and prior is vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code...
CVE-2021-42705
PLC Editor Versions 1.3.8 and prior is vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code...
Stack overflow
PLC Editor Versions 1.3.8 and prior is vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code...
Out-of-bounds
PLC Editor Versions 1.3.8 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code...
CVE-2021-42705 WECON PLC Editor
PLC Editor Versions 1.3.8 and prior is vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code...
CVE-2021-42705
CVE-2021-42705 affects WECON PLC Editor (Versions 1.3.8 and earlier). The vulnerability is a stack-based buffer overflow occurring while processing WCP/project files, leading to arbitrary code execution in the context of the affected process. Public sources (ZDI/CISA ICS advisory) describe the fl...