3061 matches found
Schneider Electric 多款产品跨站请求伪造漏洞
Schneider Electric Modicon Quantum and others are products of Schneider Electric, France.Schneider Electric Modicon Quantum is a large programmable logic controller PLC for process applications, high availability and safety solutions.Schneider Electric Modicon M340 is a mid-range PLC programmable...
WAGO 750-8xxx PLC Denial Of Service / User Enumeration
SEC Consult Vulnerability Lab Security Advisory ======================================================================= title: Denial of service & User Enumeration product: WAGO 750-8xxx PLC vulnerable version: Firmware 20 Patch 1 v03.08.08 fixed version: Firmware 20 Patch 1 v03.08.08 CVE number:...
CVE-2021-20612
Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service DoS conditio...
CVE-2021-20613
Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service DoS condition in communication...
Input validation
Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service DoS condition in communication...
Design/Logic Flaw
Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service DoS conditio...
CVE-2021-20612
Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service DoS conditio...
Unspecified vulnerability in IDEC PLC (CNVD-2022-02761)
The IDEC PLC is a programmable controller. A security vulnerability exists in the IDEC PLC that can be exploited by an attacker to obtain user credentials from a file server, a backup repository, or a ZLD file saved on an SD card...
Unspecified Vulnerability in IDEC PLC
The IDEC PLC is a programmable controller. The IDEC PLC has a security vulnerability that can be exploited by an attacker to obtain user credentials from the communication between the PLC and the software...
lms.accessbankplc.com Cross Site Scripting vulnerability OBB-2316126
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
CVE-2021-37401
An attacker may obtain the user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the PLC user program may be uploaded, altered, and/or downloaded...
CVE-2021-37401
An attacker may obtain the user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the PLC user program may be uploaded, altered, and/or downloaded...
CVE-2021-37400
An attacker may obtain the user credentials from the communication between the PLC and the software. As a result, the PLC user program may be uploaded, altered, and/or downloaded...
Design/Logic Flaw
An attacker may obtain the user credentials from the communication between the PLC and the software. As a result, the PLC user program may be uploaded, altered, and/or downloaded...
Design/Logic Flaw
An attacker may obtain the user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the PLC user program may be uploaded, altered, and/or downloaded...
CVE-2021-37400
The CVE-2021-37400 issue affects IDEC IDEC PLCs (e.g., FC6A/FC6B MICROSmart modules, FT1A SmartAXIS Pro/Lite, WindLDR, WindEDIT Lite, Data File Manager) where credentials are transmitted without proper protection. The root cause is Unprotected Transport of Credentials (CWE-523) in PLC-to-software...
CVE-2021-37400
An attacker may obtain the user credentials from the communication between the PLC and the software. As a result, the PLC user program may be uploaded, altered, and/or downloaded...
CVE-2021-37401
IDEC PLCs are affected by CVE-2021-37401 (Plaintext storage of a password). The trusted‑credentials leakage occurs when an attacker obtains user credentials from file servers, backup repositories, or ZLD files saved on SD cards, enabling unauthorized PLC program upload/alteration/download. The jo...
CVE-2021-37401
An attacker may obtain the user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the PLC user program may be uploaded, altered, and/or downloaded...
Multiple vulnerabilities in IDEC PLCs
Overview Multiple PLCs provided by IDEC Corporation contain multiple vulnerabilities listed below. Unprotected transport of credentials CWE-523 - CVE-2021-37400 Plaintext storage of a password CWE-256 - CVE-2021-37401 Unprotected transport of credentials CWE-523 - CVE-2021-20826 Plaintext storage...