3061 matches found

CNNVD
CNNVD
added 2025/04/30 12:0 a.m.9 views

Delta Electronics ISPSoft 安全漏洞

Delta Electronics ISPSoft is a programmable logic controller PLC programming software from Delta Electronics. An out-of-bounds write vulnerability exists in Delta Electronics ISPSoft, which can be exploited by an attacker to execute arbitrary code while parsing a DVP file...

9.8CVSS7.9AI score0.00354EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2025/04/30 12:0 a.m.9 views

Delta Electronics ISPSoft 缓冲区错误漏洞

Delta Electronics ISPSoft is a programmable logic controller PLC programming software from Delta Electronics. A stack buffer overflow vulnerability exists in Delta Electronics ISPSoft, which can be exploited by an attacker to execute arbitrary code while parsing a DVP file...

9.8CVSS8AI score0.00362EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2025/04/30 12:0 a.m.10 views

Delta Electronics ISPSoft 安全漏洞

Delta Electronics ISPSoft is a programmable logic controller PLC programming software from Delta Electronics. An out-of-bounds write vulnerability exists in Delta Electronics ISPSoft, which can be exploited by an attacker to execute arbitrary code while parsing an ISP file...

9.8CVSS7.9AI score0.00348EPSS
SaveExploits0References1
NVD
NVD
added 2025/03/18 11:15 a.m.14 views

CVE-2024-41975

An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs...

5.3CVSS0.00417EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2025/03/18 11:4 a.m.17 views

CVE-2024-41975 CODESYS (Edge) Gateway for Windows insecure default

An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs...

5.3CVSS0.00417EPSS
SaveExploits0References1
CVE
CVE
added 2025/03/18 11:4 a.m.65 views

CVE-2024-41975

CVE-2024-41975 concerns the CODESYS Edge Gateway for Windows with insecure defaults. Public sources converge on an unauthenticated remote attacker being able to obtain limited information about the PLC network; however, careful access controls in PLC user management appear to prevent actual contr...

5.3CVSS5.5AI score0.00417EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2025/03/18 11:4 a.m.13 views

CVE-2024-41975 CODESYS (Edge) Gateway for Windows insecure default

An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs...

5.3CVSS5.4AI score0.00417EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/02/05 10:28 p.m.15 views

CVE-2022-45794

An attacker with network access to the affected PLC CJ-series and CS-series PLCs, all versions may use a network protocol to read and write files on the PLC internal memory and memory card...

8.6CVSS6.7AI score0.00536EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/02/05 8:35 a.m.12 views

CVE-2024-47134

Out-of-bounds write vulnerability exists in Kostac PLC Programming Software Former name: Koyo PLC Programming Software Version 1.6.14.0 and earlier. Having a user open a specially crafted project file which was saved using Kostac PLC Programming Software Version 1.6.9.0 and earlier may cause a...

7.8CVSS7.2AI score0.00274EPSS
SaveExploits0
RedhatCVE
RedhatCVE
added 2025/02/05 8:31 a.m.10 views

CVE-2024-47136

Out-of-bounds read vulnerability exists in Kostac PLC Programming Software Former name: Koyo PLC Programming Software Version 1.6.14.0 and earlier. Having a user open a specially crafted project file which was saved using Kostac PLC Programming Software Version 1.6.9.0 and earlier may cause a...

7.8CVSS7.1AI score0.00274EPSS
SaveExploits0
RedhatCVE
RedhatCVE
added 2025/02/05 8:18 a.m.12 views

CVE-2024-47135

Stack-based buffer overflow vulnerability exists in Kostac PLC Programming Software Former name: Koyo PLC Programming Software Version 1.6.14.0 and earlier. Having a user open a specially crafted project file which was saved using Kostac PLC Programming Software Version 1.6.9.0 and earlier may...

7.8CVSS7.7AI score0.00296EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/02/05 3:31 a.m.10 views

CVE-2024-45368

The H2-DM1E PLC's authentication protocol appears to utilize either a custom encoding scheme or a challenge-response protocol. However, there's an observed anomaly in the H2-DM1E PLC's protocol execution, namely its acceptance of multiple distinct packets as valid authentication responses. This...

8.8CVSS7.2AI score0.00342EPSS
SaveExploits0References1
NVD
NVD
added 2025/01/15 5:15 p.m.20 views

CVE-2024-50954

The XINJE XL5E-16T and XD5E-24R-E programmable logic controllers V3.5.3b-V3.7.2a have a vulnerability in handling Modbus messages. When a TCP connection is established with the above series of controllers within a local area network LAN, sending a specific Modbus message to the controller can cau...

7.5CVSS0.00417EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2025/01/15 12:0 a.m.5 views

CVE-2024-50954

The XINJE XL5E-16T and XD5E-24R-E programmable logic controllers V3.5.3b-V3.7.2a have a vulnerability in handling Modbus messages. When a TCP connection is established with the above series of controllers within a local area network LAN, sending a specific Modbus message to the controller can cau...

6.9AI score0.00417EPSS
SaveExploits0References1
CVE
CVE
added 2025/01/15 12:0 a.m.76 views

CVE-2024-50954

The CVE-2024-50954 issue affects XINJE XL5E-16T and XD5E-24R-E PLCs running V3.5.3b–V3.7.2a. The root cause is a vulnerability in Modbus message handling over a TCP LAN connection, which can crash the controller and disrupt operation, evidenced by the ERR indicator lighting and RUN indicator turn...

7.5CVSS6.7AI score0.00417EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2025/01/15 12:0 a.m.16 views

CVE-2024-50954

The XINJE XL5E-16T and XD5E-24R-E programmable logic controllers V3.5.3b-V3.7.2a have a vulnerability in handling Modbus messages. When a TCP connection is established with the above series of controllers within a local area network LAN, sending a specific Modbus message to the controller can cau...

0.00417EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2025/01/13 12:0 a.m.12 views

CVE-2024-57811

In Eaton X303 3.5.16 - X303 3.5.17 Build 712, an attacker with network access to a XC-303 PLC can login as root over SSH. The root password is hardcoded in the firmware. NOTE: This vulnerability appears in versions that are no longer supported by Eaton...

0.00433EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
added 2024/12/09 12:0 a.m.12 views

The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers (PLCs), such as the Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU, allows a attacker to execute a “man-in-the-middle” attack.

The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers PLCs such as Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU lies in the execution of operations outside the buffer in memory. Exploiting th...

8.1CVSS6.1AI score0.00517EPSS
SaveExploits0References2Affected Software1
Tenable Nessus
Tenable Nessus
added 2024/11/29 12:0 a.m.10 views

Phoenix Contact PLC Cycle Time Influences Uncontrolled Resource Consumption (CVE-2019-10953)

ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. This plugin only works with Tenable.ot. Please visit...

7.5CVSS7.3AI score0.03395EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2024/11/13 12:0 a.m.24 views

CVE-2024-50956

A buffer overflow in the RecvSocketData function of Inovance HCPLCAM401-CPU1608TPTN 21.38.0.0, HCPLCAM402-CPU1608TPTN 41.38.0.0, and HCPLCAM403-CPU1608TN 81.38.0.0 allows attackers to cause a Denial of Service DoS or execute arbitrary code via a crafted Modbus message...

0.0026EPSS
SaveExploits0References1