3368 matches found
CVE-2025-54811: Reliance on Undefined, Unspecified, or Implementation-Defined Behavior
OpenPLCV3 has a vulnerability in the enipThread function that occurs due to the lack of a return value. This leads to a crash when the server loop ends and execution hits an illegal ud2 instruction. This issue can be triggered remotely without authentication by starting the same server multiple...
OpenPLC_V3
RISK EVALUATION Successful exploitation of this vulnerability could cause a denial of service, making the PLC runtime process crash. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network...
CVE-2025-58069
The use of a hard-coded cryptographic key was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software contains a hard-coded AES key used to protect the initial messages of a new KOPS session...
CVE-2025-59484
The use of a broken or risky cryptographic algorithm was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software uses an insecure implementation of the RSA encryption algorithm...
CVE-2025-55038
An authorization bypass vulnerability has been discovered in the Click Plus C2-03CPU2 device firmware version 3.60. Through the KOPR protocol utilized by the Remote PLC application, authenticated users with low-level access permissions can exploit this vulnerability to read and modify PLC variabl...
CVE-2025-55038
An authorization bypass vulnerability has been discovered in the Click Plus C2-03CPU2 device firmware version 3.60. Through the KOPR protocol utilized by the Remote PLC application, authenticated users with low-level access permissions can exploit this vulnerability to read and modify PLC variabl...
CVE-2025-55069
A predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the...
CVE-2025-57882 AutomationDirect CLICK PLUS Improper Resource Shutdown or Release
An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all available device sessions in the Remote PLC...
CVE-2025-57882
CVE-2025-57882 affects the Click Plus C2-03CPU-2 device with firmware 3.60. It describes an improper resource shutdown/release that allows an unauthenticated attacker to cause a denial-of-service by exhausting all sessions in the Remote PLC application. Public documents confirm the issue and deta...
CVE-2025-55038
CVE-2025-55038 affects AutomationDirect CLICK PLUS C2-03CPU2 firmware 3.60. Through the KOPR protocol used by the Remote PLC app, authenticated users with low-level permissions can read and modify PLC variables beyond their authorization. Documents substantiate an authorization bypass with impact...
CVE-2025-55038 AutomationDirect CLICK PLUS Missing Authorization
An authorization bypass vulnerability has been discovered in the Click Plus C2-03CPU2 device firmware version 3.60. Through the KOPR protocol utilized by the Remote PLC application, authenticated users with low-level access permissions can exploit this vulnerability to read and modify PLC variabl...
CVE-2025-55038 AutomationDirect CLICK PLUS Missing Authorization
An authorization bypass vulnerability has been discovered in the Click Plus C2-03CPU2 device firmware version 3.60. Through the KOPR protocol utilized by the Remote PLC application, authenticated users with low-level access permissions can exploit this vulnerability to read and modify PLC variabl...
CVE-2025-55069 AutomationDirect CLICK PLUS Predictable Seed in Pseudo-Random Number Generator
A predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the...
CVE-2025-58069
The use of a hard-coded cryptographic key was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software contains a hard-coded AES key used to protect the initial messages of a new KOPS session...
CVE-2025-59484
CVE-2025-59484 affects AutomationDirect CLICK PLUS firmware 3.60, where an insecure RSA implementation enables use of a broken cryptographic algorithm. Public sources (NVD/Red Hat CVEs, CVE list, PT Security, and CISA advisory) describe the issue and confirm the affected device (Click Plus PLC) a...
CVE-2025-58069
The CVE pertains to AutomationDirect CLICK PLUS firmware 3.60, where a hard-coded AES key is used to protect the initial messages of a new KOPS session. Root cause: hard-coded cryptographic key stored in the firmware. Impact: potential exposure of the cryptographic key and associated initial comm...
PT-2025-39222
Name of the Vulnerable Software and Affected Versions Click Plus PLC firmware version 3.60 Description A flaw exists in the pseudo-random number generator due to a predictable seed. This compromises the security of generated private keys. Recommendations Update to a newer firmware version that...
PT-2025-39226
Name of the Vulnerable Software and Affected Versions Click Plus C2-03CPU2 version 3.60 Description An authorization bypass exists in the Click Plus C2-03CPU2 device firmware. An authenticated user with low-level access can exploit this issue through the KOPR protocol, used by the Remote PLC...
PT-2025-39223
Name of the Vulnerable Software and Affected Versions Click Plus PLC version 3.60 Description A hard-coded cryptographic key is present in firmware version 3.60 of the Click Plus PLC. This key, an AES key, is used to protect the initial messages of a new KOPS session. Recommendations At the momen...
AutomationDirect CLICK PLUS 安全漏洞
The AutomationDirect CLICK PLUS is a small programmable logic controller from AutomationDirect, Inc. A security vulnerability exists in AutomationDirect CLICK PLUS version 3.60, which stems from improper authorization of the KOPR protocol, and could result in a low-privileged user overstepping...