Lucene search
+L

1862 matches found

Tenable Nessus
Tenable Nessus
•added 2023/03/01 12:00 a.m.•22 views

Schneider Electric Modicon M221 Programmable Logic Controller Use of a One-Way Hash with a Predictable Salt (CVE-2020-28214)

A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 all references, all versions, that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictab...

9.8CVSS5.8AI score0.00734EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/01 12:00 a.m.•33 views

Schneider Electric Modicon Uncontrolled Resource Consumption (CVE-2013-2763)

DISPUTED The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service resource consumption via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it could not be duplicated and an attacker could not remotely exploit this observed behavior t...

5CVSS5.8AI score0.02133EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2023/03/01 12:00 a.m.•36 views

Schneider Electric Modicon M221 Improper Check For Unusual or Exceptional Conditions (CVE-2018-7789)

An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product all references, all versions prior to firmware V1.6.2.0. The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames...

7.8CVSS6.8AI score0.02797EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
•added 2023/03/01 12:00 a.m.•46 views

Wago PLC Cycle Time Influences Uncontrolled Resource Consumption (CVE-2019-10953)

ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. This plugin only works with Tenable.ot. Please visit...

7.5CVSS7.2AI score0.03395EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/01 12:00 a.m.•24 views

Schneider Electric Modicon Insufficient Verification of Data Authenticity (CVE-2020-7487)

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

9.8CVSS8.6AI score0.00692EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2023/03/01 12:00 a.m.•37 views

Schneider Electric Modicon M221 Information Management Errors (CVE-2018-7790)

An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product all references, all versions prior to firmware V1.6.2.0. The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a...

9.8CVSS7.3AI score0.02478EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2023/03/01 12:00 a.m.•20 views

Schneider Electric Modicon M221 Programmable Logic Controller Missing Encryption of Sensitive Data (CVE-2020-7567)

A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke t...

7.1CVSS6AI score0.00206EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/01 12:00 a.m.•32 views

Schneider Electric Modicon PLCs Insufficiently Protected Credentials (CVE-2017-6028)

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials...

9.8CVSS7.2AI score0.0225EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/02/28 12:00 a.m.•20 views

Schneider Electric Modicon Out-of-bounds Write (CVE-2020-7502)

A CWE-787: Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller Firmware version 4.3 and prior, which may cause a Denial of Service when specific TCP/IP crafted packets are sent to the Modicon M218 Logic Controller. This plugin only works with Tenable.ot. Please visit...

7.5CVSS7.5AI score0.01525EPSS
SaveExploits0References2
The Hacker News
The Hacker News
•added 2023/02/16 1:18 p.m.•10 views

Researchers Warn of Critical Security Bugs in Schneider Electric Modicon PLCs

Security researchers have disclosed two new vulnerabilities affecting Schneider Electric Modicon programmable logic controllers PLCs that could allow for authentication bypass and remote code execution. The flaws, tracked as CVE-2022-45788 CVSS score: 7.5 and CVE-2022-45789 CVSS score: 8.1, are...

9.8CVSS7.9AI score0.03049EPSS
SaveExploits0
The Hacker News
The Hacker News
•added 2023/02/16 1:18 p.m.•132 views

Researchers Warn of Critical Security Bugs in Schneider Electric Modicon PLCs

Security researchers have disclosed two new vulnerabilities affecting Schneider Electric Modicon programmable logic controllers PLCs that could allow for authentication bypass and remote code execution. The flaws, tracked as CVE-2022-45788 CVSS score: 7.5 and CVE-2022-45789 CVSS score: 8.1, are...

9.8CVSS1.2AI score0.03049EPSS
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2023/02/08 12:00 a.m.•54 views

Schneider Electric Modicon Exposure of Sensitive Information to an Unauthorized Actor (CVE-2021-22786)

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU part numbers BMXP34 Versions prior to V3.30, Modicon M580 CPU par...

7.5CVSS7.4AI score0.0063EPSS
SaveExploits0References2
NVD
NVD
•added 2023/02/01 4:15 a.m.•49 views

CVE-2021-22786

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU part numbers BMXP34 Versions prior to V3.30, Modicon M580 CPU par...

7.5CVSS7.3AI score0.0063EPSS
SaveExploits0References1
OSV
OSV
•added 2023/02/01 4:15 a.m.•18 views

CVE-2021-22786

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU part numbers BMXP34 Versions prior to V3.30, Modicon M580 CPU par...

7.5CVSS5.8AI score0.0063EPSS
SaveExploits0References1
Prion
Prion
•added 2023/02/01 4:15 a.m.•36 views

Information disclosure

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU part numbers BMXP34 Versions prior to V3.30, Modicon M580 CPU par...

5CVSS7.3AI score0.0063EPSS
SaveExploits0References1Affected Software41
Cvelist
Cvelist
•added 2023/02/01 12:00 a.m.•62 views

CVE-2021-22786

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU part numbers BMXP34 Versions prior to V3.30, Modicon M580 CPU par...

7.5CVSS7.5AI score0.0063EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2023/02/01 12:00 a.m.•16 views

CVE-2021-22786

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU part numbers BMXP34 Versions prior to V3.30, Modicon M580 CPU par...

7.5CVSS7.3AI score0.0063EPSS
SaveExploits0References1
CVE
CVE
•added 2023/02/01 12:00 a.m.•96 views

CVE-2021-22786

Schneider Electric CVE-2021-22786 is an information-exposure vulnerability in Modicon controllers over Modbus TCP. Affected products/versions: Modicon M340 CPU (BMXP34*) prior to V3.30, M580 CPU (BMEP*/BMEH*) prior to SV3.20, MC80 (BMKC80) prior to V1.6, M580 Safety (BMEP58*/BMEH58*) all versions...

7.5CVSS7.2AI score0.0063EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/02/01 12:00 a.m.•6 views

CVE-2021-22786: Exposure of Sensitive Information to an Unauthorized Actor

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU part numbers BMXP34 Versions prior to V3.30, Modicon M580 CPU par...

7.5CVSS5.8AI score0.0063EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2023/02/01 12:00 a.m.•29 views

多款Schneider Electric产品 信息泄露漏洞

The Schneider Electric Modicon M580 and Schneider Electric Modicon M340 are both products of the French company Schneider Electric.The Schneider Electric Modicon M580 is a programmable automation The Schneider Electric Modicon M340 is a medium-range PLC programmable logic controller for industria...

7.5CVSS7.3AI score0.0063EPSS
SaveExploits0References2