1669 matches found
CVE-2014-0777
The Modbus slave/outstation driver in the OPC Drivers 1.0.20 and earlier in IOServer OPC Server allows remote attackers to cause a denial of service out-of-bounds read and daemon crash via a crafted packet...
Out-of-bounds
The Modbus slave/outstation driver in the OPC Drivers 1.0.20 and earlier in IOServer OPC Server allows remote attackers to cause a denial of service out-of-bounds read and daemon crash via a crafted packet...
CVE-2014-0777 OServer Out of Bounds Read
The Modbus slave/outstation driver in the OPC Drivers 1.0.20 and earlier in IOServer OPC Server allows remote attackers to cause a denial of service out-of-bounds read and daemon crash via a crafted packet...
CVE-2014-0777
The CVE-2014-0777 issue affects IOServer’s OPC Server (Windows) in the Modbus slave/outstation driver present in OPC Drivers 1.0.20 and earlier. The root cause is an out-of-bounds read in the Modbus driver, which attackers can trigger with a crafted packet to cause denial of service (daemon crash...
CVE-2013-0662
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...
Stack overflow
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...
Schneider Electric产品基于栈的缓冲区溢出漏洞
Bugtraq ID:66500 CVE ID:CVE-2013-0662 施耐德电气为100多个国家的能源及基础设施、工业、数据中心及网络、楼宇和住宅市场提供整体解决方案。 Schneider Electric多个产品使用的Modbus Serial驱动监听TCP 27700端口,当处理连接时,Modbus应用头字段会最先读入缓冲区,当在头字段指定超大缓冲区大小时可触发基于栈的缓冲区溢出,成功利用漏洞可以以应用程序上下文执行任意代码。 0 Schneider Electric TwidoSuite Versions 2.31.04 Schneider Electric PowerSui...
CVE-2013-0662
The CVE-2013-0662 vulnerability affects Schneider Electric’s Modbus Serial Driver (ModbusDrv.exe) used by multiple Schneider Electric products. A stack-based buffer overflow is triggered when a large value is specified in the Modbus Application Header, enabling remote code execution with the user...
CVE-2013-0662
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...
Patch Available for Schneider Electric Serial Modbus Driver
Schneider Electric, a leading provider of industrial control systems, recently patched a remotely exploitable vulnerability in a driver found in 11 of its products. The Industrial Control Systems Computer Emergency Response Team ICS-CERT released an advisory yesterday alerting users to the...
MODBUS Server Diagnostic Mode (SCADA) (deprecated)
Binary data 3849.prm...
MODBUS/TCP 'Clear Counters and Diagnostic Register' Function Code Detection
Binary data 7102.pasl...
MODBUS/TCP 'Device Identification' Function Code Detection
Binary data 7105.pasl...
MODBUS/TCP 'Force Listen Mode' Function Code Detection
Binary data 7101.pasl...
MODBUS/TCP 'Report Server ID' Function Code Detection
Binary data 7103.pasl...
MODBUS/TCP 'Return Query Data' Function Code Detection
Binary data 7099.pasl...
MODBUS/TCP 'Restart Communications' Function Code Detection
Binary data 7100.pasl...
Modicon Modbus/TCP Programming Function Code Access (SCADA) (deprecated)
Binary data 3852.prm...
MODBUS/TCP 'CANopen' Function Code Detection
Binary data 7104.pasl...
MODBUS/TCP Server Detection
Binary data 7092.pasl...