2042 matches found
CVE-2019-6549
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 through FTP...
CVE-2019-6549
CVE-2019-6549 concerns the PR100088 Modbus gateway where plain-text credentials are stored in an XML file and can be retrieved via FTP on all versions prior to Release R02 (or Software Version 1.1.13166). The issue is categorized under Information Exposure Through Get/Internal File Storage, enabl...
CVE-2019-6549
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 through FTP...
Authentication flaw
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...
CVE-2019-6533
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...
CVE-2019-6527
PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...
CVE-2019-6527
PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...
CVE-2019-6533
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...
Design/Logic Flaw
PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...
CVE-2019-6527
PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...
CVE-2019-6533
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...
CVE-2019-6533
CVE-2019-6533 affects the Kunbus PR100088 Modbus Gateway. Registers used to store Modbus values can be read and written through the web interface without authentication on versions prior to Release R02 (or Software Version 1.1.13166). Public sources (NVD/NVD-linked advisories, ICS-CERT) corrobora...
CVE-2019-6527
CVE-2019-6527 affects Kunbus PR100088 Modbus gateway: versions prior to Release R02 (or Software Version 1.1.13166) are vulnerable to an improper authentication flaw that may allow an attacker to change an admin password for a user who is currently or previously logged in, provided the device has...
CVE-2019-6549: Cleartext Storage of Sensitive Information
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 through FTP...
CVE-2019-6527: Improper Authentication
PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...
CVE-2019-6533: Missing Authentication for Critical Function
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...
PT-2019-18161
Name of the Vulnerable Software and Affected Versions PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 Description An issue exists where an attacker could retrieve plain-text credentials stored in an XML file through FTP. Recommendations For versions prior to...
PT-2019-18140 · Unknown · Modbus Gateway
Name of the Vulnerable Software and Affected Versions: Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 Description: The issue allows an attacker to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...
PT-2019-18145 · Pr Electronics · Pr100088 Modbus Gateway
Name of the Vulnerable Software and Affected Versions: PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 Description: The issue allows registers used to store Modbus values to be read and written from the web interface without authentication. Recommendations: For...
What you can learn from Cisco Talos’ new oil pumpjack workshop
Paul Rascagneres wrote this blog post with contributions from Patrick DeSantis from Cisco Talos ARES Advanced Research/Embedded Systems. Executive summary Every day, more industrial control systems ICS become vulnerable to cyber attacks. As these massive, critical machines become more...