Lucene search
K

1669 matches found

NVD
NVD
added 2019/02/12 5:29 p.m.18 views

CVE-2019-6527

PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...

9.8CVSS9.6AI score0.01214EPSS
Exploits0References1
NVD
NVD
added 2019/02/12 5:29 p.m.16 views

CVE-2019-6533

Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...

9.1CVSS9.3AI score0.01226EPSS
Exploits0References1
Prion
Prion
added 2019/02/12 5:29 p.m.15 views

Authentication flaw

Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...

6.4CVSS9.1AI score0.01226EPSS
Exploits0References1Affected Software1
OSV
OSV
added 2019/02/12 5:29 p.m.2 views

CVE-2019-6527

PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...

9.8CVSS7.2AI score0.01214EPSS
Exploits0References1
Prion
Prion
added 2019/02/12 5:29 p.m.19 views

Design/Logic Flaw

PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...

7.5CVSS9.4AI score0.01214EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2019/02/12 5:0 p.m.21 views

CVE-2019-6527

PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...

9.5AI score0.01214EPSS
Exploits0References1
Cvelist
Cvelist
added 2019/02/12 5:0 p.m.19 views

CVE-2019-6533

Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...

9.2AI score0.01226EPSS
Exploits0References1
CVE
CVE
added 2019/02/12 5:0 p.m.47 views

CVE-2019-6533

CVE-2019-6533 affects the Kunbus PR100088 Modbus Gateway. Registers used to store Modbus values can be read and written through the web interface without authentication on versions prior to Release R02 (or Software Version 1.1.13166). Public sources (NVD/NVD-linked advisories, ICS-CERT) corrobora...

9.1CVSS9.1AI score0.01226EPSS
Exploits0References1Affected Software1
CVE
CVE
added 2019/02/12 5:0 p.m.44 views

CVE-2019-6527

CVE-2019-6527 affects Kunbus PR100088 Modbus gateway: versions prior to Release R02 (or Software Version 1.1.13166) are vulnerable to an improper authentication flaw that may allow an attacker to change an admin password for a user who is currently or previously logged in, provided the device has...

9.8CVSS9.3AI score0.01214EPSS
Exploits0References1Affected Software1
Positive Technologies
Positive Technologies
added 2019/02/12 12:0 a.m.4 views

PT-2019-18145 · Pr Electronics · Pr100088 Modbus Gateway

Name of the Vulnerable Software and Affected Versions: PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 Description: The issue allows registers used to store Modbus values to be read and written from the web interface without authentication. Recommendations: For...

9.1CVSS9AI score0.01226EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2019/02/12 12:0 a.m.3 views

PT-2019-18140 · Unknown · Modbus Gateway

Name of the Vulnerable Software and Affected Versions: Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 Description: The issue allows an attacker to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted...

9.8CVSS9.5AI score0.01214EPSS
Exploits0References2
Talos Blog
Talos Blog
added 2019/02/11 8:2 a.m.109 views

What you can learn from Cisco Talos’ new oil pumpjack workshop

Paul Rascagneres wrote this blog post with contributions from Patrick DeSantis from Cisco Talos ARES Advanced Research/Embedded Systems. Executive summary Every day, more industrial control systems ICS become vulnerable to cyber attacks. As these massive, critical machines become more...

0.4AI score
Exploits0
ICS
ICS
added 2019/02/05 12:0 a.m.124 views

Kunbus PR100088 Modbus Gateway (Update B)

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Kunbus Equipment: PR100088 Modbus gateway Vulnerabilities: Improper Authentication, Information Exposure Through Query Strings in GET Request, Missing Authentication for Critical Function, Imprope...

9.8CVSS8.1AI score0.01226EPSS
Exploits0References5
NVD
NVD
added 2018/11/16 6:29 p.m.19 views

CVE-2018-18759

Modbus Slave 7.0.0 in modbus tools has a Buffer Overflow...

7.5CVSS7.5AI score0.0875EPSS
Exploits5References2
OSV
OSV
added 2018/11/16 6:29 p.m.2 views

CVE-2018-18759

Modbus Slave 7.0.0 in modbus tools has a Buffer Overflow...

7.5CVSS5.8AI score
Exploits0References2
Prion
Prion
added 2018/11/16 6:29 p.m.10 views

Buffer overflow

Modbus Slave 7.0.0 in modbus tools has a Buffer Overflow...

5CVSS7.5AI score0.0875EPSS
Exploits5References2Affected Software1
Cvelist
Cvelist
added 2018/11/16 6:0 p.m.24 views

CVE-2018-18759

Modbus Slave 7.0.0 in modbus tools has a Buffer Overflow...

7.5AI score0.0875EPSS
Exploits5References2
CVE
CVE
added 2018/11/16 6:0 p.m.51 views

CVE-2018-18759

CVE-2018-18759 affects Modbus Slave 7.0.0 in Modbus Tools, with a buffer overflow vulnerability likely leading to denial of service. The Connected documents corroborate a PoC that crafts an input buffer of 603 characters to trigger the overflow, as part of Denial of Service demonstrations. No ven...

7.5CVSS7.4AI score0.0875EPSS
Exploits5References2Affected Software1
0day.today
0day.today
added 2018/10/29 12:0 a.m.63 views

Modbus Slave 7.0.0 - Denial of Service Exploit

Exploit for windows platform in category dos / poc Exploit Title: Modbus Slave 7.0.0 - Denial of Service PoC Exploit Author: Ihsan Sencan Vendor Homepage: https://www.modbustools.com/ Software Link: https://www.modbustools.com/download/ModbusSlaveSetup32Bit.exe Software Link:...

7.6AI score0.0875EPSS
Exploits5
exploitpack
exploitpack
added 2018/10/29 12:0 a.m.23 views

Modbus Slave PLC 7 - .msw Buffer Overflow (PoC)

Modbus Slave PLC 7 - .msw Buffer Overflow PoC...

2.9AI score
Exploits0
Rows per page
Query Builder