1730 matches found
CVE-2019-6856
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium see security notification for specific versions which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP...
CVE-2019-6856
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium see security notification for specific versions which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP...
PT-2020-8981
Name of the Vulnerable Software and Affected Versions Modicon M580 affected versions not specified Modicon M340 affected versions not specified Modicon Quantum affected versions not specified Modicon Premium affected versions not specified Description A vulnerability exists that could cause a...
PT-2020-11216
Name of the Vulnerable Software and Affected Versions Modicon M580 affected versions not specified Modicon M340 affected versions not specified Modicon Quantum affected versions not specified Modicon Premium affected versions not specified Description A vulnerability exists that could cause a...
CVE-2019-13944
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
CVE-2019-13943
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
Code injection
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
CVE-2019-13942
The CVE-2019-13942 issue affects Siemens EN100 Ethernet Module variants (DNP3, IEC61850
CVE-2019-13944
CVE-2019-13944 affects Siemens EN100 Ethernet Module family (DNP3, IEC61850
CVE-2019-13943
CVE-2019-13943 affects Siemens EN100 Ethernet Module variants (DNP3, IEC61850
PT-2019-13484 · Moxa · En100 Ethernet Module Modbus Tcp Variant +4
Name of the Vulnerable Software and Affected Versions: EN100 Ethernet module DNP3 variant All versions EN100 Ethernet module IEC 61850 variant All versions V4.37 EN100 Ethernet module IEC104 variant All versions EN100 Ethernet module Modbus TCP variant All versions EN100 Ethernet module PROFINET ...
Siemens EN100 Ethernet Module (Update A)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: EN100 Ethernet Module Vulnerabilities: Improper Restriction of Operations within the Bounds of a Memory Buffer, Cross-site Scripting, Relative Path Traversal 2. UPDATE...
Analysing the Attack Surface of an Industrial Data Acquisition Device
Introduction The Data Station Plus from Red Lion Controls was handed to me to analyse the attack surface. The device is designed to connect to SCADA data acquisition devices over Modbus, Profibus, etc. by Serial or Ethernet connection. Data is collected and recorded to a local compact flash card...
The vulnerability of Modicon microprogrammed controllers lies in the transmission of confidential information in open text using the Modbus TCP protocol during controller programming, allowing attackers to disclose the protected information.
The vulnerability of Modicon controllers’ microprogramming software lies in the transmission of confidential information as open text using the Modbus TCP protocol during controller programming. Exploiting this vulnerability can allow a remote attacker to disclose the protected information...
The vulnerability of Modicon microprogrammed controllers, related to the use of the Modbus service provided by the REST API, allows a hacker to disclose protected information.
The vulnerability of Modicon controller’s microprogrammed software is related to the use of the Modbus service provided by the REST API. Exploiting this vulnerability can allow a malicious actor to disclose protected information remotely...
The vulnerability of the Modbus protocol implementation in the “Communication Server” software of the EKRASMS-SP program suite for microprocessor-based EKRA 200 terminals allows a perpetrator to execute any command they desire.
The vulnerability of the Modbus protocol implementation in the “Communication Server” software of the EKRASMS-SP suite for microprocessor-based EKRA 200 terminals exists due to insufficient filtering of symbols in file paths. Exploiting this vulnerability allows a malicious actor to execute...
Siemens Siprotec Exposure of Sensitive Information to an Unauthorized Actor
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens En100 Improper Authentication
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens En100 Improper Authentication
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens Dnp3 Improper Input Validation
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...