401 matches found
Siemens SIPROTEC 4 and SIPROTEC Compact (Update C)
CVSS v3 8.6 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIPROTEC 4 and SIPROTEC Compact Vulnerabilities: Improper Input Validation, Missing Authorization, Improper Authentication UPDATE INFORMATION This updated advisory is a follow-up to the updated...
Modicon Modbus/TCP UnityPro Programming Function Code Access
Binary data scadamodbusmodiconproject.nbin...
NetMan 204 - Backdoor Account Vulnerability
Exploit for hardware platform in category remote exploits NetMan 204 - Backdoor Account Author: Saeed reza Zamanian penetrationtest @ Linkedin Product: NetMan 204 Vendor: http://www.riello-ups.com Product URL: http://www.riello-ups.com/products/4-software-connectivity/85-netman-204 Quick Referenc...
NetMan 204 - Backdoor Account
NetMan 204 - Backdoor Account NetMan 204 - Backdoor Account Author: Saeed reza Zamanian penetrationtest @ Linkedin Product: NetMan 204 Vendor: http://www.riello-ups.com Product URL: http://www.riello-ups.com/products/4-software-connectivity/85-netman-204 Quick Reference Installation Manual :...
Modbus/TCP Protocol Detection
Binary data 7227.pasl...
CVE-2016-7112
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7112
CVE-2016-7112 is an Authentication Bypass vulnerability in the Siemens EN100 Ethernet module used with SIPROTEC 4/Compact and related equipment. Affected firmware variants PROFINET IO, Modbus TCP, DNP3 TCP, and IEC 104 in all SIPROTEC 4/Compact deployments allow remote attackers with access to th...
CVE-2016-7114
Siemens SIPROTEC 4/Compact EN100 Ethernet module family is affected by CVE-2016-7114 (Improper Authentication). The vulnerability allows remote attackers with network access to the device web interface (port 80) to possibly circumvent authentication and perform administrative operations, requirin...
CVE-2016-4785
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-4784
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Design/Logic Flaw
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Smod - MODBUS Penetration Testing Framework
smod is a modular framework with every kind of diagnostic and offensive feature you could need in order to pentest modbus protocol. It is a full Modbus protocol implementation using Python and Scapy. This software could be run on Linux/OSX under python 2.7.x. Feel free to make pull requests, if...
NetworkMiner 2.0 - Network Forensic Analysis Tool (NFAT)
NetworkMiner is a Network Forensic Analysis Tool NFAT for Windows but also works in Linux / Mac OS X / FreeBSD. NetworkMiner can be used as a passive network sniffer/packet capturing tool in order to detect operating systems, sessions, hostnames, open ports etc. without putting any traffic on the...
CVE-2015-5374
CVE-2015-5374 affects Siemens SIPROTEC 4/Compact devices with EN100 Ethernet modules (PROFINET IO, Modbus TCP, DNP3 TCP, IEC 104 firmware) and SIPROTEC 6MU80 integration. The flaw is an improper input validation that allows specially crafted UDP packets to port 50000 to cause a denial-of-service,...
Modbus/TCP Report Slave ID
Binary data scadamodbusreptslvidcheck.nbin...
Modbus/TCP Device Identification
Binary data scadamodbusdevidcheck.nbin...
MODBUS/TCP Device Identification Object Detection
Binary data 7148.pasl...
Automated Solutions Modbus/TCP OPC Server Remote Heap Corruption PoC
No description provided by source. !/usr/bin/python asmb-heap.py Automated Solutions Modbus/TCP OPC Server Remote Heap Corruption PoC Jeremy Brown 0xjbrown41-gmail-com Jan 2011 A specially crafted length field in a MODBUS packet header can trigger heap corruption. 00408312 | 8B5424 3C MOV EDX,DWO...