Lucene search
+L

401 matches found

CVE
CVE
added 2019/03/21 2:57 p.m.71 views

CVE-2018-16563

Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays are affected by CVE-2018-16563 due to improper input validation. Specially crafted packets sent to TCP port 102 can cause a denial-of-service, requiring a manual restart to restore EN100 module functionality. Exploitation requires ...

5.9CVSS5.5AI score0.01155EPSS
SaveExploits0References1Affected Software3
Packet Storm
Packet Storm
added 2018/10/15 12:00 a.m.52 views

FLIR Systems FLIR AX8 Thermal Camera 1.32.16 RTSP Stream Disclosure

FLIR Systems FLIR AX8 Thermal Camera 1.32.16 RTSP Stream Disclosure Vendor: FLIR Systems, Inc. Product web page: https://www.flir.com Affected version: Firmware: 1.32.16 1.17.13 OS: necov1.8-0-g7ffe5b3 Hardware: Flir Systems Neco Board Summary: Thermal Imaging Camera For Continuous Condition and...

0.2AI score
SaveExploits0
Packet Storm
Packet Storm
added 2018/10/15 12:00 a.m.54 views

FLIR Systems FLIR AX8 Thermal Camera 1.32.16 Hard-coded Credentials Shell Access

FLIR Systems FLIR AX8 Thermal Camera 1.32.16 Hard-coded Credentials Shell Access Vendor: FLIR Systems, Inc. Product web page: https://www.flir.com Affected version: Firmware: 1.32.16 1.17.13 OS: necov1.8-0-g7ffe5b3 Hardware: Flir Systems Neco Board Summary: Thermal Imaging Camera For Continuous...

0.1AI score
SaveExploits0
Zero Science Lab
Zero Science Lab
added 2018/10/14 12:00 a.m.660 views

FLIR Systems FLIR AX8 Thermal Camera 1.32.16 Hard-coded Credentials Shell Access

Summary Thermal Imaging Camera For Continuous Condition and Safety Monitoring FLIR AX8 is a thermal sensor with imaging capabilities. Combining thermal and visual cameras in a small, affordable package, the AX8 provides continuous temperature monitoring and alarming capabilities to protec critica...

9.8CVSS7.3AI score0.00607EPSS
SaveExploits2
Zero Science Lab
Zero Science Lab
added 2018/10/14 12:00 a.m.695 views

FLIR Systems FLIR AX8 Thermal Camera 1.32.16 RTSP Stream Disclosure

Summary Thermal Imaging Camera For Continuous Condition and Safety Monitoring FLIR AX8 is a thermal sensor with imaging capabilities. Combining thermal and visual cameras in a small, affordable package, the AX8 provides continuous temperature monitoring and alarming capabilities to protec critica...

8.7CVSS5.8AI score0.0052EPSS
SaveExploits2
NVD
NVD
added 2018/07/23 9:29 p.m.30 views

CVE-2018-11451

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.8CVSS7.3AI score0.02389EPSS
SaveExploits0References3
Prion
Prion
added 2018/07/23 9:29 p.m.25 views

Design/Logic Flaw

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.8CVSS7.2AI score0.02389EPSS
SaveExploits0References3Affected Software3
CVE
CVE
added 2018/07/23 9:00 p.m.77 views

CVE-2018-11451

CVE-2018-11451 affects Siemens EN100 Ethernet Module and SIPROTEC 5 relays and is due to improper input validation. A specially crafted packet sent to port 102/tcp can cause a denial-of-service condition, affecting network availability. A manual restart is required to restore EN100 module functio...

7.8CVSS7.2AI score0.02389EPSS
SaveExploits0References3Affected Software5
CVE
CVE
added 2018/07/23 9:00 p.m.77 views

CVE-2018-11452

CVE-2018-11452 affects Siemens EN100 Ethernet Module firmware variants (IEC 61850, PROFINET IO, Modbus TCP, DNP3 TCP, IEC104). The root cause is an improper handling of crafted packets to port 102/TCP that can trigger a Denial-of-Service condition when oscillographs are running, compromising avai...

7.8CVSS7.2AI score0.02389EPSS
SaveExploits0References3Affected Software5
ICS
ICS
added 2018/07/11 12:00 a.m.101 views

ICSA-18-347-02 Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: EN100 Ethernet Communication Module and SIPROTEC 5 relays Vulnerabilities: Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a follow-up to the original...

7.8CVSS8.2AI score0.02389EPSS
SaveExploits0References9
Tenable Nessus
Tenable Nessus
added 2018/05/23 12:00 a.m.15 views

MODBUS/TCP Server Detection (SCADA)

Binary data 700242.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2018/05/23 12:00 a.m.18 views

MODBUS/TCP Client Detection (SCADA)

Binary data 700243.prm...

7.3AI score
SaveExploits0
Prion
Prion
added 2018/03/08 5:29 p.m.22 views

Authorization

A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...

5CVSS7.5AI score0.01777EPSS
SaveExploits0References2Affected Software5
OSV
OSV
added 2018/03/08 5:29 p.m.11 views

CVE-2018-4840

A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...

7.5CVSS5.7AI score0.01777EPSS
SaveExploits0References2
CVE
CVE
added 2018/03/08 5:00 p.m.81 views

CVE-2018-4840

CVE-2018-4840 affects Siemens DIGSI 4 and EN100 Ethernet modules (DNP3, IEC 104, IEC 61850, Modbus TCP, PROFINET IO). The issue allows an unauthenticated remote attacker to upload a modified device configuration that overwrites the access-authorization passwords. Affected products include DIGSI 4...

7.5CVSS7.4AI score0.01777EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2018/03/08 5:00 p.m.77 views

CVE-2018-4838

CVE-2018-4838 affects Siemens EN100 Ethernet module variants (IEC 61850 < V4.30, DNP3 < V1.04, PROFINET IO, Modbus TCP, IEC 104

7.5CVSS7.5AI score0.01404EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2018/03/08 5:00 p.m.34 views

CVE-2018-4838

A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module DNP3 variant All versions V1.04, EN100 Ethernet module PROFINET IO variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module IEC 104...

7.5AI score0.01404EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2018/03/08 5:00 p.m.35 views

CVE-2018-4840

A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...

7.5AI score0.01777EPSS
SaveExploits0References1
ICS
ICS
added 2018/03/08 12:00 a.m.75 views

ICSA-18-067-02_Siemens SIPROTEC 4, SIPROTEC Compact, and Reyrolle Devices using the EN100 Ethernet Communication Module Extension (Update B)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIPROTEC 4, SIPROTEC Compact, and Reyrolle devices using the EN100 Ethernet communication module extension Vulnerability: Missing Authentication for Critical Function 2. UPDATE...

7.5CVSS7.6AI score0.01404EPSS
SaveExploits0References2
ICS
ICS
added 2018/01/09 12:00 a.m.45 views

Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers

CVSS v3 8.6 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Rockwell Automation Equipment: Allen-Bradley MicroLogix 1400 Controllers Vulnerability: Buffer Overflow AFFECTED PRODUCTS The following versions of MicroLogix 1400 Controllers, a PLC, are affected: MicroLogix 1400...

10CVSS9.9AI score0.07145EPSS
SaveExploits0References2
Rows per page
Query Builder