Lucene search
+L

455 matches found

CVE
CVE
•added 2009/01/06 5:00 p.m.•77 views

CVE-2008-5848

The CVE-2008-5848 entry concerns the Advantech ADAM-6000 module which ships with a default password of 00000000. This default credential enables remote attackers to gain access via an HTTP session and, from there, monitor or control the module’s Modbus/TCP I/O activity. The connected sources conf...

10CVSS6.9AI score0.0339EPSS
SaveExploits0References3Affected Software14
Cvelist
Cvelist
•added 2009/01/06 5:00 p.m.•40 views

CVE-2008-5848

The Advantech ADAM-6000 module has 00000000 as its default password, which makes it easier for remote attackers to obtain access through an HTTP session, and 1 monitor or 2 control the module's Modbus/TCP I/O activity...

6.7AI score0.0339EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2009/01/06 12:00 a.m.•4 views

CVE-2008-5848: Undefined Security Weakness

The Advantech ADAM-6000 module has 00000000 as its default password, which makes it easier for remote attackers to obtain access through an HTTP session, and 1 monitor or 2 control the module's Modbus/TCP I/O activity...

10CVSS5.8AI score0.0339EPSS
SaveExploits0References2
CERT
CERT
•added 2008/10/31 12:00 a.m.•62 views

Automated Solutions Modbus TCP Slave ActiveX Control Vulnerability

Overview Automated Solutions Modbus TCP Slave ActiveX Control contains a vulnerability that may allow a remote attacker to execute arbitrary code or cause a denial-of-service. Description Automated Solutions Modbus TCP Slave ActiveX Control fails to properly process malformed "Modbus" requests to...

7.5CVSS7.6AI score0.04734EPSS
SaveExploits0References8
NVD
NVD
•added 2007/09/19 6:17 p.m.•19 views

CVE-2007-4827

Unspecified vulnerability in the Modbus/TCP Diagnostic function in MiniHMI.exe for the Automated Solutions Modbus Slave ActiveX Control before 1.5 allows remote attackers to corrupt the heap and possibly execute arbitrary code via malformed Modbus requests to TCP port 502...

7.5CVSS7.7AI score0.04734EPSS
SaveExploits0References9
CVE
CVE
•added 2007/09/19 6:00 p.m.•81 views

CVE-2007-4827

CVE-2007-4827 affects Automated Solutions Modbus Slave ActiveX Control (MiniHMI.exe) and its Modbus/TCP Diagnostic function. The vulnerability occurs when processing malformed Modbus requests to TCP port 502, causing heap corruption and potentially arbitrary code execution. The issue is remote an...

7.5CVSS7.7AI score0.04734EPSS
SaveExploits0References9Affected Software1
securityvulns
securityvulns
•added 2007/09/19 12:00 a.m.•406 views

TPTI-07-15: Automated Solutions Modbus TCP Slave ActiveX Control Heap Corruption Vulnerability

TPTI-07-15: Automated Solutions Modbus TCP Slave ActiveX Control Heap Corruption Vulnerability http://www.zerodayinitiative.com/advisories/TPTI-07-15.html September 17, 2007 -- CVE ID: CVE-2007-4827 -- Affected Vendor: Automated Solutions -- Affected Products: Modbus RTU/ASCII/TCP Slave ActiveX...

7.5CVSS1AI score0.04734EPSS
SaveExploits0
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2007/09/19 12:00 a.m.•6 views

CVE-2007-4827: Improper Restriction of Operations within the Bounds of a Memory Buffer

Unspecified vulnerability in the Modbus/TCP Diagnostic function in MiniHMI.exe for the Automated Solutions Modbus Slave ActiveX Control before 1.5 allows remote attackers to corrupt the heap and possibly execute arbitrary code via malformed Modbus requests to TCP port 502...

7.5CVSS6.5AI score0.04734EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2007/09/19 12:00 a.m.•23 views

Automated Solutions Modbus Slave MiniHMI.exe ActiveX Modbus/TCP Diagnostic Function Arbitrary Code Execution

Binary data scadaasmbslvactivexheapcorruption.nbin...

7.5CVSS7.3AI score0.04734EPSS
SaveExploits0References4
securityvulns
securityvulns
•added 2007/09/19 12:00 a.m.•37 views

Automated Solutions Modbus TCP Slave ActiveX memory corruption

Memory corruption on TCP/502 request handling...

7.5CVSS1.5AI score0.04734EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2006/12/11 12:00 a.m.•28 views

Modbus/TCP Discrete Input Access

Binary data scadamodbusdicheck.nbin...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2006/12/11 12:00 a.m.•23 views

Modicon Modbus/TCP Programming Function Code Access

Binary data scadamodbusmodiconprogram.nbin...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2006/12/11 12:00 a.m.•219 views

Modbus/TCP Coil Access

Binary data scadamodbuscoilcheck.nbin...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2006/05/08 12:00 a.m.•16 views

MODBUS/TCP Server Detection (SCADA)

Binary data 3556.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2006/05/08 12:00 a.m.•15 views

MODBUS/TCP Client Detection (SCADA)

Binary data 3557.prm...

7.3AI score
SaveExploits0
Rows per page
Query Builder