FLIR Systems FLIR AX8 Thermal Camera 1.32.16 RTSP Stream Disclosure
Summary Thermal Imaging Camera For Continuous Condition and Safety Monitoring FLIR AX8 is a thermal sensor with imaging capabilities. Combining thermal and visual cameras in a small, affordable package, the AX8 provides continuous temperature monitoring and alarming capabilities to protec critica...
CVE-2018-11451
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...
Design/Logic Flaw
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...
CVE-2018-11451
CVE-2018-11451 affects Siemens EN100 Ethernet Module and SIPROTEC 5 relays and is due to improper input validation. A specially crafted packet sent to port 102/tcp can cause a denial-of-service condition, affecting network availability. A manual restart is required to restore EN100 module functio...
CVE-2018-11452
CVE-2018-11452 affects Siemens EN100 Ethernet Module firmware variants (IEC 61850, PROFINET IO, Modbus TCP, DNP3 TCP, IEC104). The root cause is an improper handling of crafted packets to port 102/TCP that can trigger a Denial-of-Service condition when oscillographs are running, compromising avai...
ICSA-18-347-02 Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays (Update A)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: EN100 Ethernet Communication Module and SIPROTEC 5 relays Vulnerabilities: Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a follow-up to the original...
MODBUS/TCP Server Detection (SCADA)
Binary data 700242.prm...
MODBUS/TCP Client Detection (SCADA)
Binary data 700243.prm...
CVE-2018-4840
A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...
Authorization
A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...
CVE-2018-4838
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module DNP3 variant All versions V1.04, EN100 Ethernet module PROFINET IO variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module IEC 104...
CVE-2018-4838
CVE-2018-4838 affects Siemens EN100 Ethernet module variants (IEC 61850 < V4.30, DNP3 < V1.04, PROFINET IO, Modbus TCP, IEC 104
CVE-2018-4840
CVE-2018-4840 affects Siemens DIGSI 4 and EN100 Ethernet modules (DNP3, IEC 104, IEC 61850, Modbus TCP, PROFINET IO). The issue allows an unauthenticated remote attacker to upload a modified device configuration that overwrites the access-authorization passwords. Affected products include DIGSI 4...
CVE-2018-4840
A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...
ICSA-18-067-02_Siemens SIPROTEC 4, SIPROTEC Compact, and Reyrolle Devices using the EN100 Ethernet Communication Module Extension (Update B)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIPROTEC 4, SIPROTEC Compact, and Reyrolle devices using the EN100 Ethernet communication module extension Vulnerability: Missing Authentication for Critical Function 2. UPDATE...
Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers
CVSS v3 8.6 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Rockwell Automation Equipment: Allen-Bradley MicroLogix 1400 Controllers Vulnerability: Buffer Overflow AFFECTED PRODUCTS The following versions of MicroLogix 1400 Controllers, a PLC, are affected: MicroLogix 1400...
Siemens SIPROTEC 4 and SIPROTEC Compact (Update C)
CVSS v3 8.6 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIPROTEC 4 and SIPROTEC Compact Vulnerabilities: Improper Input Validation, Missing Authorization, Improper Authentication UPDATE INFORMATION This updated advisory is a follow-up to the updated...
Modicon Modbus/TCP UnityPro Programming Function Code Access
Binary data scadamodbusmodiconproject.nbin...
NetMan 204 - Backdoor Account Vulnerability
Exploit for hardware platform in category remote exploits NetMan 204 - Backdoor Account Author: Saeed reza Zamanian penetrationtest @ Linkedin Product: NetMan 204 Vendor: http://www.riello-ups.com Product URL: http://www.riello-ups.com/products/4-software-connectivity/85-netman-204 Quick Referenc...
NetMan 204 - Backdoor Account
NetMan 204 - Backdoor Account NetMan 204 - Backdoor Account Author: Saeed reza Zamanian penetrationtest @ Linkedin Product: NetMan 204 Vendor: http://www.riello-ups.com Product URL: http://www.riello-ups.com/products/4-software-connectivity/85-netman-204 Quick Reference Installation Manual :...