Lucene search
+L

134 matches found

CVE
CVE
added 2017/07/16 11:00 p.m.63 views

CVE-2017-11345

CVE-2017-11345 describes a stack buffer overflow in the networkmap component of Asuswrt-Merlin firmware and ASUS firmware for a broad range of ASUS routers (e.g., RT-AC53, RT-AC68U, RT-AC88U, RT-N66U, RT-N12, RT-AC3200, RT-AC3100, etc.). The vulnerability is triggered when a crafted device descri...

7.8CVSS8.1AI score0.0185EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2017/07/16 11:00 p.m.31 views

CVE-2017-11345

Stack buffer overflow in networkmap in Asuswrt-Merlin firmware for ASUS devices and ASUS firmware for ASUS RT-AC5300, RTAC1900P, RT-AC68U, RT-AC68P, RT-AC88U, RT-AC66U, RT-AC66UB1, RT-AC58U, RT-AC56U, RT-AC55U, RT-AC52U, RT-AC51U, RT-N18U, RT-N66U, RT-N56U, RT-AC3200, RT-AC3100, RTAC1200GU,...

8.2AI score0.0185EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2017/07/16 11:00 p.m.24 views

CVE-2017-11344

Global buffer overflow in networkmap in Asuswrt-Merlin firmware for ASUS devices and ASUS firmware for ASUS RT-AC5300, RTAC1900P, RT-AC68U, RT-AC68P, RT-AC88U, RT-AC66U, RT-AC66UB1, RT-AC58U, RT-AC56U, RT-AC55U, RT-AC52U, RT-AC51U, RT-N18U, RT-N66U, RT-N56U, RT-AC3200, RT-AC3100, RTAC1200GU,...

8.2AI score0.02764EPSS
SaveExploits0References2
ThreatPost
ThreatPost
added 2017/04/13 2:19 p.m.15 views

FDA Demands St. Jude Take Action on Medical Device Security

The U.S. Food and Drug Administration on Wednesday sent Abbott Laboratories a warning letter citing that it had inadequately addressed the security of the maligned Merlin@home Transmitter. The letter promises regulatory action against the healthcare company should vulnerabilities in the device...

0.1AI score
SaveExploits0References3
OSV
OSV
added 2017/02/13 10:59 p.m.9 views

CVE-2017-5149

An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability. The identities of the endpoints for the communication channel between the transmitter and St. Jude...

8.9CVSS5.8AI score0.0124EPSS
SaveExploits0References2
Prion
Prion
added 2017/02/13 10:59 p.m.27 views

Code injection

An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability. The identities of the endpoints for the communication channel between the transmitter and St. Jude...

6.8CVSS8.5AI score0.0124EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2017/02/13 10:00 p.m.71 views

CVE-2017-5149

Summary: CVE-2017-5149 concerns the Merlin@home transmitter from St. Jude Medical, affected versions prior to 8.2.2 (RF models EX1150; inductive models EX1100; and EX1100 with MerlinOnDemand). The issue is that the identities of the endpoints for the communication channel between the transmitter ...

8.9CVSS8.4AI score0.0124EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
added 2017/02/13 12:00 a.m.9 views

PT-2017-16344 · St. Jude Medical · Merlin@Home

Name of the Vulnerable Software and Affected Versions: St. Jude Medical Merlin@home versions prior to 8.2.2 Description: An issue was discovered where the identities of the endpoints for the communication channel between the transmitter and St. Jude Medical's web site, Merlin.net, are not verifie...

8.9CVSS8.6AI score0.0124EPSS
SaveExploits0References3
ThreatPost
ThreatPost
added 2017/02/07 1:15 p.m.11 views

St. Jude Patches Additional Cardiac Device

St. Jude Medical has patched a vulnerability in another Merlin@home Transmitter medical device vulnerable to a man-in-the-middle attack. The medical device maker issued an update on Monday for its Merlin@home Transmitter “inductive” models, expanding the number of devices impacted by a...

1AI score
SaveExploits0References7
CNVD
CNVD
added 2017/01/11 12:00 a.m.9 views

Merlin@home Man-in-the-Middle Security Bypass Vulnerability

St.JudeMedicalMerlin@hometransmitter是美国St.JudeMedical公司的一款用于对植入心脏装置的患者进行远程护理管理的产品. A man-in-the-middle security bypass vulnerability exists in Merlin@home. A remote attacker could exploit this vulnerability to access or affect communications between Merlin.net and the transmitter terminal...

8.9CVSS6.9AI score0.0124EPSS
SaveExploits0References1
Openbugbounty
Openbugbounty
added 2016/12/29 11:43 a.m.13 views

secure.merlinentertainmentsgroup.com XSS vulnerability

Open Bug Bounty ID: OBB-200872 Description| Value ---|--- Affected Website:| secure.merlinentertainmentsgroup.com Open Bug Bounty Program:| Create your bounty program now. It's open and free. Vulnerable Application:| Custom Code Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:...

6.3AI score
SaveExploits0
ThreatPost
ThreatPost
added 2016/08/26 2:55 p.m.18 views

Pacemaker Hacking Fears Rise With Critical Research Report

Pacemakers, defibrillators and other medical devices made by a leading medical equipment maker are vulnerable to potentially “catastrophic” cyberattacks. With relatively little effort tens of thousands of cardiac devices made by St. Jude Medical are vulnerable to attack, according a report releas...

1AI score
SaveExploits0References2
Packet Storm
Packet Storm
added 2011/08/04 12:00 a.m.48 views

Marc Merlin BAPPA Local File Inclusion

1-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=0 0 1 1 /' \ /'\ /\ \ /'\ 0 0 /, \ /\/\ \ \ \ \ ,/\ /\ \ 1 1 //\ \ /' \ /\ //\ Exploit database separated by exploit 0 0 // type local, remote, DoS, etc. 1 1 1 0 + Site : 1337day.com 0 1 + Support e-mail :...

7.4AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2010/11/15 12:00 a.m.201 views

Default Password (merlin) for 'mg3500' Account

The account 'mg3500' on the remote host has the password 'merlin'. An attacker may leverage this issue to gain access to the affected system. Note that some Camtron IP cameras are reported to use these credentials by default. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. account = "mg3500"...

10CVSS8.2AI score0.53618EPSS
SaveExploits46References4
Rows per page
Query Builder