277 matches found
CVE-2017-11344
CVE-2017-11344 affects Asuswrt-Merlin and ASUS firmware for multiple routers, where a global buffer overflow in the networkmap component can be exploited by hosting a crafted device description XML via a Location header in an SSDP response. This allows a remote attacker to write shellcode into th...
PT-2017-11946
Name of the Vulnerable Software and Affected Versions Asuswrt-Merlin firmware for ASUS devices versions affected versions not specified ASUS firmware for ASUS RT-AC5300, RT AC1900P, RT-AC68U, RT-AC68P, RT-AC88U, RT-AC66U, RT-AC66U B1, RT-AC58U, RT-AC56U, RT-AC55U, RT-AC52U, RT-AC51U, RT-N18U,...
PT-2017-11945
Name of the Vulnerable Software and Affected Versions Asuswrt-Merlin firmware versions affected versions not specified ASUS firmware for ASUS devices versions affected versions not specified Description A global buffer overflow issue exists in the networkmap of Asuswrt-Merlin firmware for ASUS...
PT-2017-2830
Name of the Vulnerable Software and Affected Versions Asuswrt-Merlin firmware versions for ASUS devices affected versions not specified Description The issue is caused by a stack-based buffer overflow in the ASUS Discovery.c component of the Asuswrt-Merlin firmware, specifically when handling...
FDA Demands St. Jude Take Action on Medical Device Security
The U.S. Food and Drug Administration on Wednesday sent Abbott Laboratories a warning letter citing that it had inadequately addressed the security of the maligned Merlin@home Transmitter. The letter promises regulatory action against the healthcare company should vulnerabilities in the device...
CVE-2017-6548: Improper Restriction of Operations within the Bounds of a Memory Buffer
Buffer overflows in networkmap on ASUS RT-N56U, RT-N66U, RT-AC66U, RT-N66R, RT-AC66R, RT-AC68U, RT-AC68R, RT-N66W, RT-AC66W, RT-AC87R, RT-AC87U, RT-AC51U, RT-AC68P, RT-N11P, RT-N12+, RT-N12E B1, RT-AC3200, RT-AC53U, RT-AC1750, RT-AC1900P, RT-N300, and RT-AC750 routers with firmware before...
Code injection
An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability. The identities of the endpoints for the communication channel between the transmitter and St. Jude...
CVE-2017-5149
An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability. The identities of the endpoints for the communication channel between the transmitter and St. Jude...
CVE-2017-5149
Summary: CVE-2017-5149 concerns the Merlin@home transmitter from St. Jude Medical, affected versions prior to 8.2.2 (RF models EX1150; inductive models EX1100; and EX1100 with MerlinOnDemand). The issue is that the identities of the endpoints for the communication channel between the transmitter ...
CVE-2017-5149: NULL Pointer Dereference
An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability. The identities of the endpoints for the communication channel between the transmitter and St. Jude...
PT-2017-16344 · St. Jude Medical · Merlin@Home
Name of the Vulnerable Software and Affected Versions: St. Jude Medical Merlin@home versions prior to 8.2.2 Description: An issue was discovered where the identities of the endpoints for the communication channel between the transmitter and St. Jude Medical's web site, Merlin.net, are not verifie...
St. Jude Patches Additional Cardiac Device
St. Jude Medical has patched a vulnerability in another Merlin@home Transmitter medical device vulnerable to a man-in-the-middle attack. The medical device maker issued an update on Monday for its Merlin@home Transmitter “inductive” models, expanding the number of devices impacted by a...
Merlin@home Man-in-the-Middle Security Bypass Vulnerability
St.JudeMedicalMerlin@hometransmitter是美国St.JudeMedical公司的一款用于对植入心脏装置的患者进行远程护理管理的产品. A man-in-the-middle security bypass vulnerability exists in Merlin@home. A remote attacker could exploit this vulnerability to access or affect communications between Merlin.net and the transmitter terminal...
secure.merlinentertainmentsgroup.com XSS vulnerability
Open Bug Bounty ID: OBB-200872 Description| Value ---|--- Affected Website:| secure.merlinentertainmentsgroup.com Open Bug Bounty Program:| Create your bounty program now. It's open and free. Vulnerable Application:| Custom Code Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:...
Pacemaker Hacking Fears Rise With Critical Research Report
Pacemakers, defibrillators and other medical devices made by a leading medical equipment maker are vulnerable to potentially “catastrophic” cyberattacks. With relatively little effort tens of thousands of cardiac devices made by St. Jude Medical are vulnerable to attack, according a report releas...
Marc Merlin BAPPA Local File Inclusion
1-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=0 0 1 1 /' \ /'\ /\ \ /'\ 0 0 /, \ /\/\ \ \ \ \ ,/\ /\ \ 1 1 //\ \ /' \ /\ //\ Exploit database separated by exploit 0 0 // type local, remote, DoS, etc. 1 1 1 0 + Site : 1337day.com 0 1 + Support e-mail :...
Default Password (merlin) for 'mg3500' Account
The account 'mg3500' on the remote host has the password 'merlin'. An attacker may leverage this issue to gain access to the affected system. Note that some Camtron IP cameras are reported to use these credentials by default. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. account = "mg3500"...