CVE-2018-18992
The CVE-2018-18992 issue affects LAquis SCADA/Web Server components (LCDS Laquis SCADA) prior to version 4.1.0.4150. The root cause is insufficient input sanitization that allows user input to be processed in a way that can lead to remote code execution on the server. Multiple advisories describe...
CVE-2018-19002
CVE-2018-19002 affects LCDS LAquis SCADA prior to version 4.1.0.4150. The vulnerability is due to improper control of generation of code during parsing/opening a specially crafted project file (code injection risk). Impact per sources: remote code execution, data exfiltration, or a system crash. ...
CVE-2018-19029: Untrusted Pointer Dereference
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash...
CVE-2018-18992: Improper Neutralization of Special Elements in Output Used by a Downstream Component
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server...
CVE-2018-18998: Use of Hard-coded Credentials
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges...
CVE-2018-18986: Out-of-bounds Write
LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution...
CVE-2018-19000: Authentication Bypass Using an Alternate Path or Channel
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data...
CVE-2018-18990: Relative Path Traversal
LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process...
CVE-2018-18996: Improper Neutralization of Special Elements in Output Used by a Downstream Component
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server...
CVE-2018-19002: Improper Control of Generation of Code
LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash...
CVE-2018-19004
LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration...
CVE-2018-19004
LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration...
Design/Logic Flaw
LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration...
CVE-2018-19004
Affected software/impact: LCDS LAquis SCADA prior to 4.1.0.4150 has an out-of-bounds read when opening a specially crafted project file, potentially enabling data exfiltration. Variant appears in multiple sources (NVD/NVDCV list, CNVD, ZDI advisories, and ICS-CERT). Root cause: parsing vulnerabil...
CVE-2018-19004
LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration...
CVE-2018-18988
LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file. This may allow remote code execution, data exfiltration, or cause a system crash...
CVE-2018-18988
LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file. This may allow remote code execution, data exfiltration, or cause a system crash...
CVE-2018-18988
LAquis SCADA LGX report handling is vulnerable (CVE-2018-18988). In LAquis LCDS/LGX processing, a specially crafted LGX report file can trigger code execution or other impacts. Connected advisories detail multiple correlated flaws: LGX/Report processing can be abused to execute scripts or spawn a...
CVE-2018-18988: Out-of-bounds Read
LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file. This may allow remote code execution, data exfiltration, or cause a system crash...
CVE-2018-19004: Out-of-bounds Read
LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration...