added 2021/08/20 5:35 p.m.42 views

CVE-2021-35529 Password in Memory Vulnerability in Retail Operations Product and Counterparty Settlement and Billing (CSB)

Insufficiently Protected Credentials vulnerability in client environment of Hitachi ABB Power Grids Retail Operations and Counterparty Settlement Billing CSB allows an attacker or unauthorized user to access database credentials, shut down the product and access or alter. This issue affects:...

7.7CVSS7.6AI score0.01258EPSS
SaveExploits0References3
CVE
CVE
added 2021/08/20 5:35 p.m.82 views

CVE-2021-35529

CVE-2021-35529 concerns an insufficiently protected credentials flaw in Hitachi ABB Power Grids Retail Operations (versions up to 5.7.2) and Counterparty Settlement Billing (CSB) (versions up to 5.7.2). The root cause is inadequate protection of credentials in the client environment, which could ...

7.7CVSS7.1AI score0.01258EPSS
SaveExploits0References3Affected Software2
Cvelist
Cvelist
added 2021/08/06 12:00 a.m.50 views

CVE-2021-20597

Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a...

9.3AI score0.0222EPSS
SaveExploits0References3
OpenVAS
OpenVAS
added 2021/07/22 12:00 a.m.23 views

SUSE: Security Advisory (SUSE-SU-2021:2440-1)

The remote host is missing an update for the SPDX-FileCopyrightText: 2021 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

6.5CVSS6.8AI score0.0627EPSS
SaveExploits4References7
OSV
OSV
added 2021/07/14 3:15 p.m.10 views

CVE-2021-22778

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, and SCADAPack RemoteConnect for x70, all version...

7.1CVSS7AI score0.00216EPSS
SaveExploits0References1
NVD
NVD
added 2021/07/14 3:15 p.m.27 views

CVE-2021-22778

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, and SCADAPack RemoteConnect for x70, all version...

7.1CVSS0.00216EPSS
SaveExploits0References1
NVD
NVD
added 2021/07/14 3:15 p.m.36 views

CVE-2021-22781

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, and SCADAPack RemoteConnect for x70, all version...

5.5CVSS0.00236EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2021/07/14 3:15 p.m.6 views

CVE-2021-22778

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, and SCADAPack RemoteConnect for x70, all version...

7.1CVSS7AI score0.00216EPSS
SaveExploits0References2
Prion
Prion
added 2021/07/14 3:15 p.m.40 views

Design/Logic Flaw

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, and SCADAPack RemoteConnect for x70, all version...

3.6CVSS7.2AI score0.00216EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2021/07/14 2:26 p.m.70 views

CVE-2021-22781

CVE-2021-22781 affects Schneider Electric EcoStruxure Control Expert (and Unity Pro), EcoStruxure Process Expert, and SCADAPack RemoteConnect for x70. Description: an Insufficiently Protected Credentials vulnerability could allow a leak of SMTP credentials used for mailbox authentication when an ...

5.5CVSS5.5AI score0.00236EPSS
SaveExploits0References1Affected Software3
CVE
CVE
added 2021/07/14 2:26 p.m.69 views

CVE-2021-22780

CVE-2021-22780 describes an Insufficiently Protected Credentials issue across Schneider Electric EcoStruxure product lines (EcoStruxure Control Expert/Unity Pro, EcoStruxure Process Expert, SCADAPack RemoteConnect for x70). The vulnerability allows unauthorized access to a password-protected proj...

7.1CVSS6.8AI score0.00217EPSS
SaveExploits0References1Affected Software3
CVE
CVE
added 2021/07/14 2:26 p.m.81 views

CVE-2021-22778

The CVE-2021-22778 issue is an Insufficiently Protected Credentials vulnerability affecting Schneider Electric EcoStruxure Control Expert (all versions before v15.0 SP1, including Unity Pro), EcoStruxure Process Expert (all versions, including EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect ...

7.1CVSS6.7AI score0.00216EPSS
SaveExploits0References1Affected Software3
ICS
ICS
added 2021/07/13 12:00 a.m.208 views

Schneider Electric Modicon Controllers and Software (Update A)

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor : Schneider Electric Equipment : EcoStruxure Control Expert, EcoStruxure Process Expert, SCADAPack RemoteConnect x70, SCADAPack x70 RTUs, and Modicon M580 and M340 control products Vulnerabilities :...

9.1CVSS8.4AI score0.01023EPSS
SaveExploits0References5
Prion
Prion
added 2021/06/16 8:15 p.m.19 views

Design/Logic Flaw

D-Link DIR-2640-US 1.01B04 is affected by Insufficiently Protected Credentials. D-Link AC2600DIR-2640 stores the device system account password in plain text. It does not use linux user management. In addition, the passwords of all devices are the same, and they cannot be modified by normal users...

7.2CVSS6.8AI score0.01115EPSS
SaveExploits1References4Affected Software1
CVE
CVE
added 2021/06/16 7:55 p.m.79 views

CVE-2021-34204

CVE-2021-34204 affects the D-Link DIR-2640-US (1.01B04). The root cause is Insufficiently Protected Credentials: the device stores the system account password in plain text and does not use standard Linux user management, with identical passwords across devices and non-modifiability by normal use...

7.2CVSS6.7AI score0.01115EPSS
SaveExploits1References2Affected Software1
OSV
OSV
added 2021/05/26 8:15 p.m.6 views

CVE-2021-22737

Insufficiently Protected Credentials vulnerability exists in homeLYnk Wiser For KNX and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack...

9.8CVSS5.8AI score0.0095EPSS
SaveExploits0References1
CVE
CVE
added 2021/05/26 12:00 a.m.61 views

CVE-2021-22737

The CVE-2021-22737 issue affects Schneider Electric’s homeLYnk (Wiser For KNX) and spaceLYnk, specifically versions prior to V2.60. The root cause is Insufficiently Protected Credentials, which could allow unauthorized access once credentials are discovered after a brute-force attack. Public docu...

9.8CVSS9.2AI score0.0095EPSS
SaveExploits0References1Affected Software1
ICS
ICS
added 2021/02/25 12:00 a.m.105 views

Rockwell Automation Logix Controllers (Update A)

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Rockwell Automation Equipment: Studio 5000 Logix Designer, RSLogix 5000, Logix Controllers Vulnerability: Insufficiently Protected Credentials 2. UPDATE INFORMATION This updated advisory is a...

9.8CVSS8.6AI score0.6363EPSS
SaveExploits2References5
Prion
Prion
added 2020/12/11 1:15 a.m.30 views

Design/Logic Flaw

A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1 and EcoStruxure Geo SCADA Expert 2020 Original release and Monthly Updates to September 2020, from 83.7551....

2.1CVSS7.5AI score0.00307EPSS
SaveExploits0References1Affected Software2
NVD
NVD
added 2020/11/12 7:15 p.m.27 views

CVE-2020-12333

Insufficiently protected credentials in the IntelR QAT for Linux before version 1.7.l.4.10.0 may allow an authenticated user to potentially enable escalation of privilege via local access...