Lucene search
+L

1674 matches found

ThreatPost
ThreatPost
added 2011/06/13 3:50 p.m.12 views

Siemens Patches SCADA Holes, Downplays Threat

In the wake of a report about vulnerabilities in its products, Siemens issued a patch for its Simatic S7 industrial controllers on Monday. ICS CERT, the Cyber Emergency Response Team for Industrial Control Systems, issued an alert advising Siemens customers to apply the patch. Siemens said its...

1.1AI score
SaveExploits0References8
ICS
ICS
added 2011/06/04 6:00 a.m.43 views

Siemens WinCC Flexible Runtime Heap Overflow

Overview ICS-CERT originally released Advisory ICSA-11-244-01P on the US-CERT secure Portal on September 01, 2011. This web page release was delayed to allow users sufficient time to download and install the update. Independent security researchers Billy Rios and Terry McCorkle have reported a...

9.3CVSS8AI score0.0707EPSS
SaveExploits0References10
ICS
ICS
added 2011/06/03 6:00 a.m.42 views

GE Proficy Historian Web Administrator XSS

Overview ICS-CERT originally released Advisory ICSA-11-243-02P on the US-CERT secure Portal on August 31, 2011. ICS-CERT has received a report from independent security researchers Billy Rios and Terry McCorkle concerning multiple cross-site scripting XSS vulnerabilities in the GE Intelligent...

4.3CVSS6AI score0.00908EPSS
SaveExploits0References10
ICS
ICS
added 2011/06/03 6:00 a.m.46 views

GE Intelligent Platforms Proficy Plant Applications Buffer Overflow

Overview ICS CERT originally released Advisory ICSA-11-243-01P on the US-CERT secure Portal on August 31, 2011. This web page release was delayed to allow users time to download and install the update. ICS-CERT has received a report from GE concerning a stack-based buffer overflow vulnerability i...

10CVSS7.5AI score0.04597EPSS
SaveExploits0References10
ICS
ICS
added 2011/06/03 6:00 a.m.64 views

GE Intelligent Platforms Proficy Historian Data Archiver Buffer Overflow Vulnerability

Overview ICS-CERT originally released Advisory ICSA-11-243-03P on the US-CERT secure Portal on August 31, 2011. This web page release was delayed to allow users time to download and install the update. ICS-CERT received a report from GE Intelligent Platforms and the Zero Day Initiative concerning...

10CVSS7.1AI score0.06286EPSS
SaveExploits0References10
ThreatPost
ThreatPost
added 2011/05/25 2:39 a.m.13 views

Siemens Working On Fix For 'Security Gaps' In Logic Controllers

Siemens AG said on Tuesday that it was talking to its customers about what it acknowledged were “security gaps” in its Programmable Logic Controllers PLCs, after an NSS Labs researcher disclosed the discovery of what he described as serious security holes in the company’s industrial control...

SaveExploits0References5
ThreatPost
ThreatPost
added 2011/05/24 3:20 p.m.14 views

Researcher Says Siemens Downplaying Serious SCADA Holes

Dillon Beresford, the NSS Labs researcher who disclosed serious holes in industrial control system software from Siemens says the company is downplaying the seriousness of the vulnerabilities in its public statements, and that a supposed “fix” for the vulnerabilities is inadequate. In a message...

0.5AI score
SaveExploits0References5
ICS
ICS
added 2011/05/07 6:00 a.m.59 views

Scadatec Limited Procyon Telnet Buffer Overflow

Overview ICS-CERT originally released Advisory ICSA-11-216-01P on the US-CERT Portal on August 04, 2011. This web page release was delayed to allow users sufficient time to download and install the update. ICS-CERT has received a report from Knud Højgaard of the nSense Vulnerability Coordination...

10CVSS8.3AI score0.64653EPSS
SaveExploits5References10
ICS
ICS
added 2011/04/03 6:00 a.m.46 views

ICONICS GENESIS32 and BizViz ActiveX Trusted Zone Vulnerability

Overview ICS-CERT has received a report from independent security researchers Billy Rios and Terry McCorkle concerning ICONICS GENESIS32 and BizViz products. This vulnerability involves a design issue in a GENESIS32 ActiveX control that can set an arbitrary domain to the trusted zone. ICONICS has...

9.3CVSS7.7AI score0.02692EPSS
SaveExploits0References10
Packet Storm
Packet Storm
added 2011/04/03 12:00 a.m.40 views

Antamedia Internet Cafe Software 7.1 DLL Hijack

/ Antamedia Internet Cafe Software 7.1 Insecure Permissions/DLL Loading Vendor: Antamedia Product Web Page: http://www.antamediacafe.com Affected Version: 7.1.1.0 Summary: Internet Cafe Software – Cyber Cafe software is a worldwide top selling solution for CyberCafe management and game center...

0.5AI score
SaveExploits0
securityvulns
securityvulns
added 2011/03/23 12:00 a.m.115 views

SCADA Trojans: Attacking the Grid + Advantech vulnerabilities

Hi! You can download the slides of the research I was presenting at RootedCon'11 in Madrid "SCADA Trojans: Attacking the grid". A journey into attacking the power grid. I presented: - 0days in Advantech/BroadWin WebAccess SCADA product - Weak Design/Vulnerabilities in CSE-Semaphore TBOX RTUs -...

7.2AI score
SaveExploits0
Metasploit
Metasploit
added 2011/03/21 12:00 a.m.42 views

Siemens FactoryLink vrn.exe Opcode 9 Buffer Overflow

This module exploits a stack buffer overflow in FactoryLink 7.5, 7.5 SP2, and 8.0.1.703. By sending a specially crafted packet, an attacker may be able to execute arbitrary code due to the improper use of a vsprintf function while processing the user-supplied text field. Originally found and post...

6AI score
SaveExploits0
ICS
ICS
added 2011/03/19 6:00 a.m.48 views

Sunway Force Control

Overview ICS-CERT has received a report from Security researcher Dillon Beresford of NSS Labs concerning vulnerabililities affecting Sunway ForceControl and pNetPower SCADA/HMI applications. The reported vulnerabilities are heap-based buffer overflows that could result in a denial of service or t...

10CVSS8.9AI score0.17566EPSS
SaveExploits1References10
ICS
ICS
added 2011/02/11 7:00 a.m.48 views

ICONICS GENESIS32 and BizViz ActiveX Stack Overflow

Overview Security researchers Scott Bell and Blair Strang of Security-Assessment.com have released a report detailing a stack overflow vulnerability affecting ICONICS GENESIS32 and BizViz products. The vulnerable ActiveX control, GenVersion.dll, is a component of WebHMI, which is incorporated in...

9.3CVSS8.6AI score0.38316EPSS
SaveExploits4References10
CERT
CERT
added 2011/02/03 12:00 a.m.23 views

Sielco Sistemi Winlog server stack overflow

Overview Sielco Sistemi Winlog TCP/IP server contains a stack overflow vulnerability Description According to Sielco Sistemi's website: "Winlog is a software package for SCADA/HMI applications with web support, OPC client and a wide library of communication drivers and protocols for most PLCs...

9.3CVSS7.4AI score0.40462EPSS
SaveExploits6References4
CERT
CERT
added 2011/02/03 12:00 a.m.32 views

IntelliCom NetBiter NB100 and NB200 platforms contain multiple vulnerabilities

Overview IntelliCom NetBiter products based on the NB100 and NB200 platforms contain multiple vulnerabilities. Description IntelliCom NetBiter products based on the NB100 and NB200 platforms contain multiple vulnerabilities. A user who has been authenticated at the superadmin level highest...

7.4AI score
SaveExploits0References3
CERT
CERT
added 2011/02/03 12:00 a.m.35 views

SCADA Engine BACnet OPC Client buffer overflow vulnerability

Overview SCADA Engine BACnet OPC Client contains a buffer overflow when parsing .csv files. This vulnerability may allow an attacker to execute arbitrary code. Description According to SCADA Engine website: "The SCADA Engine BACnet OPC Server is a server that provides data access DA, Alarms and...

7.9AI score
SaveExploits0References5
ICS
ICS
added 2011/02/02 7:00 a.m.57 views

AzeoTech DAQFactory Networking Vulnerabilities

Overview ICS-CERT Advisory ICSA-11-122-01 was originally released to the US-CERT Portal on May 24, 2011. This web site release was delayed to allow users sufficient time to download and install the upgrade. ICS-CERT received a report from the nSense Vulnerability Coordination Team concerning...

7.8CVSS7.1AI score0.06742EPSS
SaveExploits1References10
ICS
ICS
added 2011/01/30 7:00 a.m.31 views

7-Technologies IGSS ODBC Remote Stack Overflow

Overview Security researcher James Burton of Insomnia Security has released details of a remote stack overflow vulnerability affecting 7-Technologies 7T Interactive Graphical SCADA System IGSS. This vulnerability exists in the IGSS Open Database Connectivity ODBC service running on Port 22202/TCP...

10CVSS8.5AI score0.06879EPSS
SaveExploits0References10
The Hacker News
The Hacker News
added 2010/12/09 4:18 p.m.20 views

Understanding the Dangers of Stuxnet in Industrial Control Systems

Stuxnet is a sophisticated virus specifically designed to attack supervisory control and data acquisition SCADA systems manufactured by Siemens, a German industrial giant. These systems are commonly used to manage water supplies, power plants, and other industrial facilities, making the worm...

7.1AI score
SaveExploits0
Rows per page
Query Builder