Lucene search
+L

1674 matches found

ICS
ICS
added 2011/12/16 7:00 a.m.66 views

WellinTech KingView 6.53 KVWebSvr ActiveX

Overview This advisory is a follow-up to ICS-ALERT-11-066-01 - WellinTech KingView 6.53 ActiveX Vulnerability, published on the ICS-CERT Web page on March 7, 2011. An independent security researcher reported a stack-based buffer overflow vulnerability in an ActiveX control in WellinTech KingView...

10CVSS8.7AI score0.381EPSS
SaveExploits2References10
ThreatPost
ThreatPost
added 2011/12/14 1:23 p.m.12 views

Multiple Vulnerabilities Haunt Long List of PLC Modules

A long list of industrial-control modules manufactured by Schneider Electric and used to control operations at various industrial facilities contain multiple weaknesses and vulnerabilities that could allow an attacker to modify the firmware, login remotely and run arbitrary code on the vulnerable...

0.6AI score
SaveExploits0References3
ThreatPost
ThreatPost
added 2011/12/12 7:59 p.m.12 views

Homeland Security Warns SCADA Operators Of Internet-Facing Systems

In the wake of the hack of water and sewer infrastructure operated by a Texas community, the Department of Homeland Security is again warning owners and operators of critical infrastructure to take note of SCADA and industrial control systems that may be accessible from the Internet. DHS’s...

0.1AI score
SaveExploits0References5
ICS
ICS
added 2011/12/11 7:00 a.m.31 views

Samsung Data Management Server (Update B)

Overview This updated website posting provides new information regarding Samsung’s process for acquiring the updated software to mitigate the reported vulnerability. José A. Guasch,http://www.SecurityByDefault.com reported a SQL injection vulnerability in the Samsung Data Management Server DMS...

7.5CVSS8.2AI score0.01779EPSS
SaveExploits0References10
ThreatPost
ThreatPost
added 2011/11/22 5:07 p.m.27 views

Was The Three Character Password Used To Hack South Houston's Water Treatment Plant A Siemens Default?

Siemens said on Tuesday that it is working with the U.S. Department of Homeland Security to investigate a cyber intrusion into a water treatment plant in South Houston, Texas, but couldn’t confirm that a default, three digit password hard coded into an application used to control the company’s...

8.6AI score
SaveExploits0References5
Prion
Prion
added 2011/11/22 11:55 a.m.18 views

Xxe

The UPnP IGD implementation in the Pseudo ICS UPnP software on the ZyXEL P-330W allows remote attackers to establish arbitrary port mappings by sending a UPnP AddPortMapping action in a SOAP request to the WAN interface, related to an "external forwarding" vulnerability...

7.5CVSS7.3AI score0.01428EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2011/11/22 11:00 a.m.47 views

CVE-2011-4504

The CVE-2011-4504 entry concerns the UPnP IGD implementation in the Pseudo ICS UPnP software used by ZyXEL P-330W. The vulnerability arises in the UPnP AddPortMapping action processed on the WAN interface, related to an “external forwarding” issue, enabling remote attackers to establish arbitrary...

7.5CVSS7AI score0.01428EPSS
SaveExploits0References2Affected Software2
ThreatPost
ThreatPost
added 2011/11/08 5:03 p.m.16 views

Researchers Warn of Prison Hacks, Opening Cell Doors

In news that seems like it could be lifted from an old 24 or Prison Break plotline, authorities are concerned by new research that claims hackers could remotely open the cell doors of federal prisons. In addition to staging a jailbreak, hackers could sabotage a prison’s intercom system and...

1AI score
SaveExploits0References5
Packet Storm
Packet Storm
added 2011/10/25 12:00 a.m.67 views

OmniTouch Instant Communication Suite XSRF / XSS

TC-SA-2011-01: Multiple vulnerabilities in OmniTouch Instant Communication Suite Published: 2011/10/24 Advisory-Version: 1.0 References: - Alcatel Lucent Vulnerability Statement 2011003 Multiple vulnerabilities in OmniTouch Instant Communication Suite - CVE-2011-4058 - multiple XSS vulnerabilitie...

6.8AI score
SaveExploits1
ICS
ICS
added 2011/10/21 6:00 a.m.31 views

7-Technologies IGSS 8 ODBC Server Remote Heap Corruption

Overview ICS-CERT has received a report from independent security researcher Jeremy Brown that a remote heap corruption vulnerability exists in IGSS Interactive Graphical SCADA System Version 8 from 7-Technologies 7T. 7T has verified the vulnerability and has developed a patch. Affected Products...

10CVSS8.9AI score0.04676EPSS
SaveExploits0References10
ICS
ICS
added 2011/10/20 6:00 a.m.70 views

WellinTech Kingview 6.53 Remote Heap Overflow

Overview This advisory is a follow-up to ICS-ALERT-11-011-01 WellinTech Kingview Buffer Overflow, published on the ICS-CERT Web site on January 11, 2011. Independent security researcher Dillon Beresford reported a heap overflow vulnerability in WellinTech KingView V6.53, which may allow a remote,...

10CVSS9AI score0.20939EPSS
SaveExploits3References10
ICS
ICS
added 2011/10/20 6:00 a.m.40 views

Sielco Sistemi WinLog Stack Overflow

Overview Independent researcher Luigi Auriemma reported a stack overflow vulnerability in Version 2.07.00 of the Sielco Sistemi WinLog Lite and Winlog Pro HMI software. Sielco Sistemi has developed an update Version 2.07.01 to address this vulnerability. The researcher has verified that the updat...

9.3CVSS8.4AI score0.40462EPSS
SaveExploits6References10
ICS
ICS
added 2011/09/30 6:00 a.m.52 views

ScadaTEC ScadaPhone & Modbus TagServer Buffer Overflow Vulnerability

OVERVIEW This advisory is a follow-up to the ICS-CERT alert titled ICS-ALERT-11-255-01—ScadaTEC ScadaPhone/ModbusTagServer Buffer Overflow, which was published September 12, 2011, on the ICS‑CERT Web page. On September 12, 2011, independent security researcher Steven Seeley publicly released a...

6.8CVSS7.7AI score0.26729EPSS
SaveExploits3References10
ThreatPost
ThreatPost
added 2011/09/26 7:30 p.m.22 views

DHS Thinks Some SCADA Problems Are Too Big To Call "Bug"

The Stuxnet worm may be the most famous piece of malicious software ever written. When it was first detected, a little over a year ago, the worm sounded a warning to nations around the world that critical infrastructure systems were potential targets of attack for foreign governments and cyber...

SaveExploits0References6
ICS
ICS
added 2011/09/24 6:00 a.m.75 views

Siemens Simatic HMI Authentication Vulnerabilities

Overview ICS-CERT is aware of a public report by independent security researchers Billy Rios and Terry McCorkle concerning authentication bypass vulnerabilities affecting Siemens SIMATIC HMI products which are supervisory control and data acquisition/human-machine interface SCADA/HMI products...

10CVSS7.8AI score0.03119EPSS
SaveExploits0References10
ICS
ICS
added 2011/09/23 6:00 a.m.72 views

WellinTech KingView History Server Buffer Overflow

Overview ICS-CERT has received a report from the Zero Day Initiative ZDI concerning a heap-based buffer overflow vulnerability in WellinTech’s Kingview HistoryServer.exe, which may allow a remote, unauthenticated attacker to execute arbitrary code. This vulnerability was reported to ZDI by...

10CVSS7.7AI score0.08527EPSS
SaveExploits0References10
ICS
ICS
added 2011/09/23 6:00 a.m.71 views

7-Technologies IGSS Buffer Overflow

Overview Security researcher Celil Unuver SignalSEC LLCSignalSEC LLC, www.signalsec.com, website last accessed December 21, 2011. has identified a buffer overflow vulnerability in the 7-Technologies 7T Interactive Graphical SCADA System IGSS product. Successful exploitation of this vulnerability...

7.5CVSS8AI score0.04492EPSS
SaveExploits0References10
ICS
ICS
added 2011/09/21 6:00 a.m.46 views

7-Technologies Interactive Graphical SCADA

Overview ICS-CERT originally released Advisory ICSA-11-353-01P on the US-CERT secure portal on December 19, 2011. This web page release was delayed to allow users time to download and install the update. Researcher Kuang-Chun Hung of Security Research and Service Institute--Information and...

9.3CVSS7.3AI score0.01787EPSS
SaveExploits0References10
Packet Storm
Packet Storm
added 2011/09/17 12:00 a.m.36 views

Measuresoft ScadaPro 4.0.0 Remote Command Execution

$Id: scadaprocmdexe.rb 13737 2011-09-16 08:23:59Z sinn3r $ This file is part of the Metasploit Framework and may be subject to redistribution and commercial restrictions. Please see the Metasploit Framework web site for more information on licensing and terms of use...

0.7AI score
SaveExploits0
ICS
ICS
added 2011/09/11 6:00 a.m.104 views

Siemens FactoryLink Multiple ActiveX Vulnerabilities

Overview ICS-CERT originally released Advisory ICSA-11-343-01P on the US-CERT secure portal on December 09, 2011. This web page release was delayed to allow users time to download and install the update. Researcher Kuang-Chun Hung of Taiwan’s Information and Communication Security Technology Cent...

9.3CVSS8AI score0.04564EPSS
SaveExploits0References10
Rows per page
Query Builder